refereed paper stormwater treatment
Antecedent dry period was not identified as a constraint, due
to the impervious nature of the catchment and the absence of a
base flow; however, at least a three-day antecedent dry period
was preferred. If the storm was deemed to qualify, Stormwater360
would inform Cairns Water and Waste Laboratory Services
(Cairns Water, NATA accreditation # 14204) that samples required
VEE NOTCH
WEIR
collection and analysis. Analysis was performed by Cairns
PRESSURE
TRANSDUCER
Water and Waste Laboratory Services, ALS Laboratory Group
– Brisbane (ALS, NATA accreditation # 825). All water quality
OUTLET PIPE
parameters for qualifying storms were sent to an independent
ROAD
peer reviewer at Queensland University of Technology (QUT),
ensuring transparency of data. Test methods for water quality
analysis used for this study are provided in Table 1.
DRAIN
SAMPLING TUBE
Gross pollutants were not monitored as part of this
study, although significant quantities were captured. Previous
AUTOSAMPLER
monitoring by White et al. (2001) demonstrated that the
AUTOSAMPLER
FLOW METER
Enviropod® filter retained all (100%) litter up to an approach
flow of 100L/sec.
NEL
CHAN
PLAN LAYOUT
Results and Discussion
The system was installed at the Streets Creek site in March 2006
Figure 3. Schematic of the sampling location. and remained an active treatment and sampling site for four
years until being decommissioned in March 2010. Stormwater360
Sampling Procedure and Equipment monitored the system from April 2008 to December 2009. During
A graphical representation of the system is shown in Figure 2. this time, the unit was maintained annually, prior to the onset
The direction of flow through the gully pit insert (EnviroPod®) of each dry season. Complete maintenance involved removing
and into the cartridge media filter (StormFilter®) is shown in all sediments and debris from the system, gully pit insert and
sequence from 1 to 4. The gully pit insert is intended to treat replacing the cartridge media. The gully pit insert required
most flows and filter solids above 100 µm while containing additional manual maintenance approximately once per year.
contaminants in a dry state. Maintenance frequencies for the study were conducted
in line with the systems standard operational lifecycle. Due to
After treatment by the gully pit insert, water is filtered radially
the nature of the catchment and size, there was an absence of
through the media cartridge (outside to inside). The media
a base flow or dry weather flows. Potential pollutant leaching
cartridge had a nominal flow rate of 0.95 L/s (at 46 cm head,
of soluble contaminants was, however, still accounted for;
when the cartridge is primed) and a peak flow rate of ca. 1.3 L/s
organic debris left within the system was allowed to break
(at maximum 0.88 m head prior to bypass). The ZPGTM media
down between maintenance periods and permitted to be
used was a proprietary blend containing perlite (50%), granular
sampled by the effluent sampler during storm events.
activated carbon (GAC, 10%) and zeolite (40%).
A summary of the principal analytes sampled is contained
The system samples were collected using automated
in Table 2.
influent and effluent samplers (Figure 3), collecting continuous
flow and precipitation data and water quality simultaneously. Suspended Solids
The influent sampler was programmed to send an SMS alert
to Stormwater360, via the GSM cellular network, when the ANZECC (2000), DECC (2007) and Fletcher et al. (2004)
have identified suspended solids as a stressor of aquatic
sampling program was triggered. A dial-up connection was
ecosystems. In addition, many of the other pollutants, such
then made to each sampler to download data for analysis.
as metals, hydrocarbons etc, are transported attached to the
To qualify as a representative sample, the following criteria suspended solids and sediment. The system achieved an SSC
were specified.
Table 2. Summary of results.
I. Collection of at least three
simultaneous influent and Range of Median Range of Median Mean Removal
No. of
effluent samples per storm; Analyte Influent EMCs Influent EMC Effluent EMCs Effluent EMC Efficiency
events
(mg/L) (mg/L) (mg/L) (mg/L) (Sum of Loads)
II. Samples must have been
SSC 6 75 to 4384 1181 8 to 63 20 99%
collected while the treatment
system operated within SSC < 500
6 48 to 180 105 8 to 62 20 78%
design flow rates (not in micron
bypass); TP 6 0.08 to 0.19 0.123 0.02 to 0.15 0.055 47%
III. The sampled portion of the TN 6 0.6 to 1.5 1.045 0.2 to 0.9 0.615 44%
storm event must represent 0.175 to
TKN 6 0.6 to 1.2 1.007 0.515 49%
at least 60% of the storm 0.800
total flow volume; NH3-N 6 0.05 to 0.15 0.050 0.05 to 0.07 0.050 31%
IV. A minimum of six data sets TOC 6 3 to 16 7 3 to 10 5 32%
must be collected for a full
DOC 6 3 to 12 7 3 to 11 6 21%
performance evaluation.
water SEPTEMBER 2011 3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.