                  safely located and freely accessible with an onsite water volume of not
                  water supply is provided for fire less than 5,000 litres; and
                  fighting purposes, which is in 2.            a water supply outlet pipe
                  addition to day to day water supply. 50 millimetres in diameter and
                                                      fitted with a standard fire brigade
                                                      fitting connected to the water
                                                      supply (other than where the water
                                                      supply is in a swimming pool or
                                                      dam).


                                                      Editor’s Note — Water supply
                                                      capacity for firefighting purposes is
                                                      in addition to water supply capacity
                                                      for household use.

                  Flood Hazards                      AO16.1 Where the development is Not applicable
                  PO16 Development is designed located in the Flood Hazard Area as The site is not mapped in the
                  and sited to ensure risk to people shown on Flood Hazard Overlay Flood Hazard Area.
                  and property from flooding is Map in Schedule 2, the finished
                  avoided or minimised.              floor level of habitable rooms is at
                                                     least 300 millimetres above the
                                                     Defined flood event (DFE).


                                                      OR


                                                      AO16.2 Where the DFE has not Not applicable
                                                      been modelled for the area, the
                                                      finished floor level of habitable
                                                      rooms is at least 500 millimetres
                                                      above the highest recorded flood.


                                                      Editor's Note—The QDC mandatory
                                                      provisions MP3.5 also apply to the
                                                      construction of buildings in flood
                                                      hazard areas.

                  Major Electricity Infrastructure AO18.1 Development including any Not applicable
                  & Substations                       sensitive land uses is at least:   The site is not mapped as
                  PO18 Development is sufficiently 1.          50     metres      from a containing major electricity
                  separated from major electricity transmission substation;              infrastructure or substations.
                  infrastructure and substations to 2.         10 metres from any other
                  minimise the likelihood of nuisance substation; and
                  or complaint.
                                                      3.       30     metres      from a
                                                      transmission line easement.
                                                      AO18.2 Habitable buildings are not Not applicable
                                                      located within an easement for a The site is not mapped as
                                                      distribution line.                 containing major electricity
                                                                                         infrastructure or substations.

                  Landslide Hazard Area               AO22.1                                  Alternate Solution



                                                                                                                    29

Document Set ID: 22343518
Version: 1, Version Date: 16/03/2023
Log in to download the original file

ECM_22343518_v1_Town Planning Assessment Report (1).pdf · 7.4 MB (large file)