Rfi - 51 Hilton Tce_Da[7]
LEGEND
NOTES
GENERAL/SITE PLAN:
EX: EXISTING
PR: PROPOSED
INT: INTERNAL ROOF TILES:
EXT: EXTERNAL FIXING: ROOF TILES, INCLUDING HIP, RIDGE,
DP: DOWNPIPE BARGE, AND CAPPING TILES, MUST BE FIXED IN
DN: DOWN ACCORDANCE WITH WIND CLASSIFICATIONS N1,
RW: RAINWATER TANK N2, AND N3 AS PER NCC 2022, CLAUSE 7.3.2.
SL: SEWER LINE SARKING: ALL TILED ROOFS WITH A PITCH OF LESS
GR: GUTTER THAN 18 DEGREES MUST BE PROVIDED WITH
RL: REFERENCE LEVEL 11,065 SARKING. SARKING INSTALLATION SHOULD
TL: TOP OF SLAB COMPLY WITH AS 4200.1 AND MUST HAVE
FL: FLOOR LEVEL 8,146 OVERLAPS OF NOT LESS THAN 150MM, AS
FF: FLOOR FINISH REQUIRED BY NCC 2022, CLAUSE 7.3.6.
A: AREA ANTI-PONDING: INSTALL ANTI-PONDING BOARDS
COS: CONFIRM ON SITE WHERE SARKING IS PRESENT ON ROOFS WITH A
FFA: FINISHED FLOOR AREA PITCH LESS THAN 20° OR WHERE ROOFS HAVE NO
25
FFL: FINISHED FLOOR LEVEL EAVES OVERHANG, IN LINE WITH NCC 2022,
MH: MANHOLE CLAUSE 7.3.6.3.
HWS: HOT WATER SYSTEM GUTTERS:
HP: HEAT PUMP INSTALLATION: EAVES GUTTERS MUST BE
LPG: LIQUEFIED PETROLEUM INSTALLED WITH A FALL OF NOT LESS THAN 1:500,
GAS CYLINDER SUPPORTED AT INTERVALS NOT EXCEEDING 1.2
AP: ACCESS PANEL METERS, AND FITTED WITH OVERFLOW MEASURES
AHD: AUSTRALIAN HEIGHT IN ACCORDANCE WITH NCC 2022, CLAUSE 7.4.3.
DATUM DOWNPIPES: EACH DOWNPIPE MUST NOT SERVE
MORE THAN 12 METERS OF GUTTER AND 50m2
DESIGN ELEMENTS: ROOF AREA. DOWNPIPE SHOULD BE POSITIONED
SH: SHELVES AS CLOSE TO VALLEY GUTTERS AS POSSIBLE, AS
6,584
6,584
PITCH: 10.2°
OHC: OVERHEAD AREA: 54.7 m2 PER NCC 2022, CLAUSE 7.4.4 AND NCC PART 3.5.3
CUPBOARDS METAL: COLORBOND VALLEY GUTTERS: VALLEY GUTTERS MUST HAVE A
CONC.: CONCRETE (PLAIN OR MINIMUM PITCH OF 12.5 DEGREES AND COMPLY
SPECIFIED FINISH) WITH THE DIMENSIONS AND RAINFALL INTENSITY
BT: BATHTUB REQUIREMENTS SPECIFIED IN NCC 2022, CLAUSE
TS: TOWEL RAIL/STAND 7.4.4.
PB: POWER BOARD
EF: EXHAUST FAN UNLESS OTHERWISE SPECFIED, GUTTER
TOTAL ROOF PERIMETER: 57,384mm
RL: ROOF LIGHT TOTAL LENGTH COVERED BY EAVES <600mm: 40,650mm SHOULD BE MINIMUM;
WHB: WASH HAND BASIN EAVE % : 70% OF ROOF PERIMETER HAS 600mm EAVE OR MORE
121mm
KITCHEN & LAUNDRY:
DW: DISHWASHER
74mm
REF: REFRIGERATOR 8954mm 2
WM: WASHING MACHINE
255
255
DR: DRYER
UBO: UNDER BENCH OVEN
WO: WALL OVEN
SS: STAINLESS STEEL SINK
PAN: PANTRY
UNLESS OTHERWISE SPECIFIED, DOWNPIPES
DOORS & WINDOWS: TO BE MINIMUN 90mm DIAMETER
SL: SKYLIGHT
OSL: OPERABLE SKYLIGHT
PITCH: 2.9°
LV: LOUVER AREA: 124.0 m2
ED: EXISTING DOOR METAL: COLORBOND
6,073
PD: PROPOSED DOOR
EW: EXISTING WINDOW
7,144
PW: PROPOSED WINDOW
FIRE SAFETY:
SD: SMOKE DETECTOR
(CEILING MOUNTED &
HARDWIRED WITH BATTERY
BACK-UP AS PER AS
3786-2014 & NCC 2022)
HATCH DENOTES EXTENT OF EAVE
COVERAGE <600mm
7,325 11,105
REV CHANGE NAME DATE
COUNCIL RFI
07 4/02/2026
AMENDMENTS
06 DETAIL KITCHEN PLAN 15/12/2025
05 MINOR CHANGES 13/10/2025
PROPOSED ROOF PLAN 04 DA PLANS 23/09/2025
1:100 07
PRELIMINARY DRAWINGS - NOT FOR CONSTRUCTION. REV.
MIDLIGHT BUILDING DESIGN
ASHTON GENRICH
[email protected]
0430 770 158
0 5 10
ROOF PLAN
DRAWING TITLE
11
SHEET
QBCC: 15387939
Charlie J L Ng & Sarah Gottsmann
250040
ABN: 29832798610
GUIDE SCALE 1:100 AT A3
ALL RIGHTS RESERVED. THIS WORK IS PROTECTED BY COPYRIGHT AND MAY NOT BE
REPRODUCED, DISTRIBUTED, OR TRANSMITTED IN ANY FORM OR BY ANY MEANS-WHETHER
GRAPHIC, ELECTRONIC, OR MECHANICAL-WITHOUT PRIOR WRITTEN PERMISSION FROM
Noosa Shire Australia #### 120 RP70296 643.43m2 51 Hilton Terrace, Tewantin 4565
MIDLIGHT DESIGN CO. AUTHORITY: COUNTY: PARISH: LOT No: RP No: AREA: CLIENT JOB No.
GSPublisherVersion 224.60.84.66 TEMPL. VER.:61
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
The download may take up to a minute.