MCU15/0036 Annexure C (Amended)- Noosa Heads And Community Use Code

of 10

Page text shows just the words. Original shows the document exactly as it was published.

Table 14-17 All Community uses
                               column 1                                                     column 2                                                       column 3
                         Specific Outcomes                                              Probable Solutions                                                Compliance
Electricity supply infrastructure
O1 The development does not adversely impact on existing or      S1.1 No solution provided                                          Complies – located away from existing infrastructure
future electricity supply infrastructure;                        S2.1 Development for uses adjacent to or within 50m of an          Complies
AND                                                              existing electricity substation incorporates noise attenuation
                                                                 measures to mitigate noise impacts;
                                                                 AND
O2 All uses and works maintain an adequate safe distance from    S2.2 Buildings and structures (including swimming pools,           Complies
electrical infrastructure including substations, overhead        sheds, tennis courts and outbuildings) are not constructed
powerlines, power poles and transformers                         under overhead electricity transmission lines, or within
                                                                 electricity easements;
                                                                 AND
                                                                 S2.3 A minimum separation distance is maintained from the          Complies
                                                                 electricity transmission line to the closest boundary of
                                                                 habitable buildings and child activity areas , as follows—
                                                                    a) 20m for transmission lines up to 132kV;
                                                                    b) 30m for transmission lines between 133kV and 275kV;
                                                                    and
                                                                    c) 40m for transmission lines greater than 275kV

Road network function
O3 The use does not have an adverse impact on the safety and     No solution provided                                               Complies – use will not impact on the road network.
efficiency of the road network;
AND
O4 The surrounding road system is capable of accommodating                                                                          Complies – existing road system is capable of supporting
additional traffic generate d by the proposal

Noise and visual amenity
O5 The use does not have a significant adverse impact on the     S5.1 If the use involves outdoor courts including tennis courts,   Not applicable - No outdoor courts proposed.
amenity enjoyed by users of adjoining or nearby premises;        half courts or netball courts —the use complies with the
AND                                                              requirements in Section 2 of PSP8 Tennis and Other Courts.
O6 Development is designed and sited to avoid adverse noise
impacts associated with neighbouring noise sources by—           S6.1 Noise sensitive Community Uses are not located                Not applicable
a) locating the use away from major noise sources such as busy   adjacent to the major road network;
roads or rail corridors;                                         OR
or                                                               S6.2 Double glazed windows are used to mitigate noise;             Not applicable
b) applying appropriate noise attenuation measures into the      OR
development                                                      S6.3 Solid concrete articulated fences are constructed on-         Not applicable
                                                                 site to attenuate noise;
                                                                 AND
                                                                 S6.4 Where the site adjoins properties in a residential zone       Not applicable




                                                                                                                                                                                   6|Page
01820 Noosa Council
Log in to download the original file

MCU15_0036 Annexure C (Amended)- Noosa Heads And Community Use Code.pdf · 66 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.