Original source · versioned page text
MCU15/0036 Annexure C (Amended)- Noosa Heads And Community Use Code
c) hardy vandal proof materials and anti-graffiti paint are Proposal able to comply with requirements.
used in the construction of buildings, where appropriate
O15 Lighting of appropriate intensities is provided to maximise S15.1 Lighting of appropriate intensities is provided which Proposal able to comply with requirements.
safety. satisfies the requirements of Australian Standard AS1158:
Public Lighting Code, unless otherwise specified in this Code;
AND
S15.2 External lighting of a graduated intensity is provided Proposal able to comply with requirements.
which starts at a lower level of brightness at the perimeter of
the site and rises to a greater intensity at the entrance to
buildings, or at the centre of the site;
AND
S15.3 Lighting is directed onto the site and away from Proposal able to comply with requirements.
neighbouring properties;
AND
S15.4 Vandal-resistant lighting is used in public and publicly Proposal able to comply with requirements.
accessible areas.
O16 Public toilets are designed and constructed to: S16.1 Features that may legitimise loitering, such as seating or Not applicable – storage facility only no toilets required for
a) ensure the safety of all people using them; and public telephones are not located in proximity to toilet ntrances; proposed use.
b) take advantage of informal surveillance from adjoining uses and AND
activities, discouraging non-legitimate uses S16.2 Public toilets are located in high traffic areas;
AND
S16.3 Entrances to public toilets are visible from the street,
footpath and other activity areas on the site or adjoining sites
Mechanical plant and equipment and storage Areas
O17 Mechanical plant and equipment (including air conditioning S17.1 Mechanical plant and equipment are— Proposal is for a lifeguard storage facility. No equipment or
equipment) and storage areas are designed and located to— a) located more than 2m from any property boundary; plant is proposed to be located outside the proposed
a) avoid adverse visual impacts when viewed from the street and b)where located at ground level, screened by fencing 1.5m in building.
adjoining properties; and height or dense vegetation of at least 1.5m in width
b) be visually integrated with the building design incorporating grouped trees and shrubs with maximum
separation distance of 1m measured from the centre of the
tree or scrub; and
c) visually integrated into the line and plane of the building
and roof design and do not project beyond the height or width
of the building when viewed from the street and adjoining
properties.
Transport and access
O18 Premises have accessibility to public transport and cycling S18.1 Safe and convenient pathway access is provided from Premises are located in close proximity to existing
and walking is promoted. the site to link to existing pathway networks that services pathways.
public transport facilities;
OR
S18.2 Direct pathway access is provided to the public transport
facility if the facility is contained on site or within 50m from the
property boundary.
9|Page
01820 Noosa Council
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.