Compliance cert Form 15 ENGINEERNG 56 Reserve St Pomona
BRACING NOTES
B1 BRACING TYPE (h) METHOD 'B' AS PER
"A.S.1684.2-2010" TABLE 8.18 AT 6kN/m FOR MIN.
900mm LENGTH. BRACING TO BE INSTALLED IN
ACCORDANCE WITH MANUFACTURERS SPECIFICATION TO
ACHIEVE 6kN/m.
B2 FOR LESS THAN 900mm LENGTH PROVIDE M12 ANCHOR
RODS AT EACH END OF PLY BRACING WALL.
B3 FOR WALLS SHEETED ON BOTH SIDES, PROVIDE M12
ANCHOR RODS AT EACH END OF PLY BRACING WALL.
900 PLY
B4 BRACING WALLS ARE TO BE CONNECTED TO THE ROOF
FRAMING OR TO THE CEILING OR TO THE EXTERNAL
900 PLY WALL FRAME IN ACCORDANCE WITH "A.S.1684.2-2010".
900 PLY
THE CONNECTION IS TO BE OF EQUAL STRENGTH TO THE
BRACING STRENGTH THAT IS REQUIRED BY THE
BRACING WALL.
B5 FOR WALLS HIGHER THAN 2700mm A HEIGHT REDUCTION
FACTOR HAS BEEN APPLIED IN ACCORDANCE WITH
"A.S.1684.2-2010".
LEGEND
900 PLY
900 PLY
900 PLY
INDICATES PLY BRACE WALL BELOW
900 PLY 900 PLY 900 PLY 900 PLY
900 PLY 900 PLY
900 PLY
900 PLY
900 PLY
900 PLY
900 PLY
900 PLY
900 PLY
900 PLY
900 PLY
900 PLY 900 PLY 900 PLY
WALL BRACING PLAN
SCALE 1:100
DO NOT SCALE FROM DRAWING
ALL SCALES ARE AS SHOWN (A3)
REV. DESCRIPTION DATE INIT. CONTACT DETAILS CLIENT PROJECT TITLE DRAWN DESIGNED DATE
A PRELIMINARY ISSUE 22.08.22 C.Y. EMAIL [email protected]
C.Y. C.Y. AUG 2022
WEB www.peerce.com.au CHECKED APPROVED
B PRELIMINARY ISSUE 29.08.22 C.Y.
PROPOSED NEW DWELLING N.Z.
0 FOR CONSTRUCTION 30.08.22 C.Y. MOBILE 0425 885 440
LEIF O'BRIEN WALL BRACING PLAN
POST PO BOX 5296 56 RESERVE STREET, DRAWING No. REV.
ALGESTER, QLD 4115
POMONA QLD 4568 PCE2211 - S08 0