Skip to the record
The first. The best. The only NoosaWatch™.

Original source · versioned page text

Appendix 5 - ARPANSA EME Report

Attached to the e-mail MCU15/0034 Development Application - Cover letter, Forms, Proposal plans & Planning Reports.

of 3

Page text shows just the words. Original shows the document exactly as it was published.

Radio Systems at the Site
There are currently no existing radio systems for this site.

It is proposed that this base station will have equipment for transmitting the following services:
                Carrier                                                                     Radio Systems
               NBN Co                        LTE2300 (proposed)



Calculated EME Levels
This table provides calculations of RF EME at different distances from the base station for emissions from existing equipment
alone and for emissions from existing equipment and proposed equipment combined.
                                                                  Maximum Cumulative EME Level – All carriers at this site
   Distance from the antennas
  at Schreibers 249 Schreibers                                Existing Equipment                                   Proposed Equipment
                Rd
                                             Electric Field     Power Density % ARPANSA              Electric Field     Power Density % ARPANSA
      in 360 circular bands                     V/m               mW/m²      exposure limits            V/m               mW/m²      exposure limits
             0m to 50m                                                                                     0.5                0.67            0.0067%
            50m to 100m                                                                                   0.43                0.49            0.0049%
           100m to 200m                                                                                   1.59                6.7              0.067%
           200m to 300m                                                                                   1.63               7.059             0.071%
           300m to 400m                                                                                   1.35                4.85             0.049%
           400m to 500m                                                                                   1.014               2.73             0.027%
                                                                                                          1.63               7.059               0.071
       Maximum EME level                                                                              216.96 m from the antennas at Schreibers
                                                                                                                 249 Schreibers Rd

Calculated EME levels at other areas of interest
This table contains calculations of the maximum EME levels at selected areas of interest that have been identified through the
consultation requirements of the Communications Alliance Ltd Deployment Code C564:2011 or via any other means. The
calculations are performed over the indicated height range and include all existing and any proposed radio systems for this site.
                                                                                                      Maximum Cumulative EME Level
                                                                      Height / Scan                         All Carriers at this site
           Additional Locations                                      relative to location             Existing and Proposed Equipment
                                                                        ground level
                                                                                               Electric Field      Power Density         % of ARPANSA
                                                                                                   V/m                mW/m²              exposure limits
   Residence on Schreibers Road                                          0m to 3m                  0.35                  0.33                0.0033%
   Residence On Sankeys Road                                             0m to 3m                  0.33                  0.29                0.0029%




Environmental EME report (v11.3, Feb 2014)                                                        Produced with RF-Map 2.0 (Build 1.18) NAD (v1.0.53334.25518)
Log in to download the original file

Appendix 5 - ARPANSA EME Report.pdf · 269 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.