owner's responsibility and independent from each other. Typically in this situation the new allotments could be
serviced by an E2 pump well with a 50mm poly line discharging into either a common discharge manhole or
alternately the Council existing manhole may need to be lined or equivalent system acceptable to Council.
3.3. Storm water Drainage
The site falls from Webb Road or the top northerly corner from roughly, RL 50m, to the southern beach side at,
RL 42.5m. Webb Road falls away from the property's entrance, with the local catchment discharging into a gully
on Webb Road into a piped drainage system that ultimately outlets onto the beach at Ed Webb Park.
A pathway reserve is located along the southern property boundary, with pit and pipe roofwater drainage
located near the bottom proportion of this pathway. A small roofwater pit that services the subject and
neighboring properties was noted, with this system discharging into a natural gully at the southern corner of the
site.
It is recommended that the current outlet position be maintained. Consequently, roofwater pits and pipe along
the rear boundary of the proposed new allotments covered by easement, if required by Council is proposed.
This piped drainage would then also discharge into the existing outlet, which is currently protected by gabion
mattresses which transitions the flow into the natural gully. The existing protection is expected to be adequate
for the increased flow. No siltation or erosion issues are expected.
4.0 Conclusions
In conclusion, based on the investigations undertaken the proposed new allotments can be adequately serviced.
Though the use of a common services trench both water and sewerage service can be provided. With the
provision of private individual sewerage pump stations. Roofwater can be provided along the rear boundary,
and discharged so as to maintain existing outlet conditions.
C7J
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Application Forms REC11/0145Related documentApplication case desk ↗
About this file
- File size
- 24.3 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.