RFI - Attachment A - rev proposal plans · MCU20/0026
Plans and drawings: the text below has words only, no drawings.
Very large file (26.7 MB): may take a few minutes to open.
A B C D E
ST
6840 1980 7680 4000
1 existing dwelling
400.02 existing
CP stormwater
1 1 BUP 5815 1 1
400.05 400.03 400.04
ST
300.04
site boundary | 38.150 | 48° 23'
site b
.00
20
ound
ST
ST
ST ST
ST ST
ST
easement
ary |
natural ground
7.081
| 303
2x mdp01 bbq01 2.5m side setback
1
° 41'
40"
mdp01
Shr up up
step 4 3 2 1
2660
til01
Lobby seat
Cellar RL 19.510
til01 con01 pool to protrude LESS THAN 1m
RL 19.510 Powder above finish ground level adjacent
2 FFL 18.770
shr seat
1980
Lift Outdoor Room
RL 18.770 Pool
1
400.01
4
3 tim02
line of building over
3
2x mdp01 2 1
300.03
1
up
Gym natural ground
v er
RL 19.510
yo
con01
tore
1 1
5440
Pool House
rd s
400.00 050.02 RL 18.070
RL 18.770
of 3
con01
l ine
1 seat pool deck less than 1m above
300.00
Pool Deck natural ground level
site boundary
RL 18.070
hwu01 hwu01 Store seat 3
2
1
4 mdp01 sliding gates up 2.5m side setback
shr
| 8.268 | 313
up up RL 17.570 up
9.0m rear setback
5 4 3 2 1 10 9 8 7 6 5 4 3 2 1
4 3 2 1
line of stairs above
0
17.00
19 .00
° 29' 30"
18.0
natural ground
site boundary | 35.647 | 228° 23'
line of building over
red hatch area complies with "basement" area to the right of the red line constitutes
definition according to the code therefore 1 the first "level" as defined by the code. the
300.02
does not constitute as a level red line indicates the limit of the upper most
level & as below this zone is 3 levels
LOT 598
neighbouring duplex neighbouring duplex
entry stair below covered walkway below RP 48112
existing 3 storey
duplex dwelling
DRAWN REV DATE ISSUE PROJECT CLIENT DRAWING NAME PHASE DWG NO REV PROJECT NO 0309
DL
DL
D
E
13.05.20
08.06.20
Council RFI
Revised Council Submission
40 Park Crescent, Asha & Sandeep Floor plans SD 200.00 G SCALE 1 : 100
Ground floor
DL F 10.06.20 Revised Council Submission
Sunshine Beach Biswas
DL G 29.07.20 Revised DA Submission schematic design
Do not scale from drawings. Dimensions are to be checked on site prior to commencement of work. Discrepancies to be brought to the attention of the author. Any dimensions not nominated must be referred to the Architect for confirmation. The concepts and information contained in this document are the copyright of Architect. Use or copying of the document in whole or in part without the written permission of the Architect constitutes an infringement of copyright.
1:1 @ A3
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
RFI - Attachment A - rev proposal plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 26.7 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.