Appendix D - 52 Hastings Street, Noosa Heads - Change Application 17.1.19 · 51994.1435.01
Attached to the e-mail Change to DA (Include Outdoor Dining Area & Awning Structure) 51994.1435.01.
Appendix D – Shade Structure Certification MINOR CHANGE TO DEVELOPMENT – APPROVED PLANS 52 Hastings Street, NOOSA HEADS described as Lot 6 BUP 4745 Applicant: Pressure Drop Pty Ltd (Café Le Monde) Date: 17th January 2019 Unit 5, 100 Pickering Street, Enoggera 1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 10 pages
Page 2
_ IDAS DECISION NOTICE - APPROVAL jcontinued...) DECISION NOTICE APPROVAL Sustainable Planning Act 2005 s.335 Go ol d Coast 9/1 Nerang Street Nerang QLD 4241 fding Approvals PO Box 1019 Nerang QLD 4211 Phone: (07) 5596 1308 Fax: (07} 5596 1302 Email: [email protected] Website: gcba ABN: 65 123 009 049 BA: 21406 Date: 06/11/2012 Cafe Le Monde Ryan Taylor §2 Hastings Street Noosa RE: Application for Shade Coverings as constructed Awnings / Annex §2 Hastings Street NOOSA HEADS QLD 4567 L6 BUP4745 Dear Sir/Madam, | wish to advise that, on 06/11/2012, the above development application for Application for Shade Coverings as constructed Awnings / Annex - was - Approved in full with conditions; OR Approved in part for the following, 1. Details of the approval - The following type of approval has been issued - Building Approval for As constructed awnings / annex class 10 structures Development | Preliminary Permit Approval e Carrying out building work BZ o (assessable under the Building Act 1975) a 2. The currency period - Two years from the date of this decision notice, any extension to be applied for before the expiry date. OR he following currency periods apply to the following aspects of development in this approval,
Page 3
3. The approved plans - The approved plans and / or documents for this development approval are listed in the following table - Plan / Document Number Plan / Document Name Date WwD202 Sunshine Coast approved Plans 09/07/2008 1001 GMD design & details Dec 11 3101 to 3114 GMD design & details None Given 4. Other necessary development permits - Listed below are other development permits that are necessary to allow the development to be carried out - ¢ Other relevant local authority approvals e Plumbing & Drainage © See attached 5. Codes for self-assessable development The following codes must be complied with for self-assessable development related to the development approval - Sunshine Coast Regional Council Plans Approved 6. Previous approvals Any works to the completed are to be consistent with previous development approval from Noosa/Tewantin number SCRC issued on 09/07/2008. 7. IDAS referral agencies - 8. Appeal rights - Below is an extract from the Sustainable Planning Act 2009 which details your appeal rights regarding this decision. Appeals by applicants An applicant for a development application may appeal to the Planning and Environment Court against the following: * the refusal, or refusal in part of the development application * any condition of a development approval, another matter stated in a development approval and the identification or inclusion of a code + the decision to give a preliminary approval when a development permit was applied for + the length of a period * a deemed refusal of the development application. The timeframes for starting an appeal in the Planning and Environment Court are set out in section 464(2) of SPA. Applicants may also have a right to appeal to the Building and Development Dispute Resolution Committee. For more details, see SPA, chapter 7, part 2. 9. When the development approval takes effect - This development approval takes effect - e from the time the decision notice is given, if there is no submitter and the applicant does not appeal the decision to the court
Page 4
This approval will lapse unless substantially started within the above stated currency periods (refer to Sustainable Planning Act 2005 for further details). If you wish to discuss this matter further, please contact me on (07) 5596 1308, MM Paul McHenry — Accreditation number sear, (cc: Referral agency/s and submitters) Yours sincerely, 10. Conditions - to be constructed in’accordance with SCRC approved plans & conditions as set out by the Sunshine Coast Regional Council.
Page 5
9/1 Nerang St Nerang QLD 4211 PO Box 1019 Nerang QLD 4211 PH: (07) 5596 1308 FAX: (07) 5596 13028 Gold Coast Building Approvals Conditions and advice notes ~— class 1 & 10a BA21406 Awning / annex to Cafe Le Monde CERTIFICATES: - BA21406 — As constructed roofed area. On completion, we will need certificates for the following. Note that certificates not in the appropriate form 15 or 16 format will not be accepted. ® Termite barrier @ Engineer’s Certification form 16 for structural adequacy Truss Certificate Pre-nail frame certificate Wet area sealing Glazing Certificate (windows, shower & mirrors) Smoke alarms installation Energy efficiency installation Surveyor (for set-out or height) Fire Resistant Mineral Wool Certificate (For Fire Wall) STORMWATER Roof water is to be connected to a system discharging to ane of the following points:- e — the street channel ® — a Council stormwater drain ® Legal point of discharge Concentration of water and discharging it across property boundaries is unlawful. This includes water and discharge caused by remodelling of the site contours. INSPECTIONS of the following building elements will be required: ki Final Additional/re-inspections are charged at $125.00 + GST NOTE — Only Gold Coast Building Approvals can issue a clearance to allow footings to be poured, failure achieve this inspection result from us before pouring concrete requires us to notify the BSA. A structural engineer can still inspect the structural aspects but we are required to issue the footing Clearance. Slab & frame can be inspected by competent persons subject to prior consent and advice of the persons inspecting. For Inspection Bookings contact us on 55 966 319 Bush Fire (medium risk if 40m clear) Timber floor to have minimum 600mm _ ground clearance or be fire retardant timber. Cladding within 400mm of ground to be non- combustible or fire-retardant treated. Windows require screening with steel, bronze or aluminium mesh with gaps =<1.8mm External doors must be fitted with- a) weather strips or draught excluders to prevent the build-up of burning debris beneath the door; and b) tight fitting screen doors with corrosion resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm Vents and weepholes must be protected with spark guards made from corrosion-resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm, Timber deck gaps to be 5mm minimum and be separated from building so as not to spread fire to the building. Water & gas Service pipes to be metal and buried >300mm under ground. Gaps under corrugations or ribs of sheet roofing must be sealed or protected at the wall or fascia line by- (i) fully sarking the roof; or (iD) providing corrosion resistant steel, bronze or aluminium mesh with a maximum aperture size of 1.8mm, profiled metal sheet, neoprene seal or compressed mineral wool. FLOOD LEVEL of -----m AHD has been set for the is property (----m + 0.3m freeboard), ground level has been advised as -----| m, a surveyors certification regarding the finished floor level will be required. The Waterfront setback for this property is N/A This approval is subject to compliance with Local Authority Local Laws, By-laws and Town Planning provisions for the GCCC PLANS ON SITE : A complete set of plans endorsed by us should be kept on site to facilitate the inspections. AMENDMENTS TO THE PLANS AND RE- INSPECTIONS usually attract an additional fee. The Design Wind Speed is N3 GENERAL ADVICE (refer also to notes on drawings in red) © Balustrades generally need to be 1 metre high with maximum gaps of 125mm, Non-climbable over 4.0m. In stairs the height can be reduced to 865mm. ® — Stairs must have a suitable non-slip finish or non- skid strip at the nosing’s, Gloss polyurethane is not suitable as a stair finish. @ Second floor windows should have fall protection considered, we recommend restricting accessible openings (windows over baths, windows <1,0m) to 125mm opening or with fixed security screens. e® Wire Balustrade construction to comply with table 3.9.2.1 BCA, over 4.0m fall handrails must be non-climbable. ® ~The following must be marked grade A safety glass, refer to AS 1288-2006 for details: -Mirror Wardrobe doors -Bathroom mirrors -All bathroom & ens windows <2.0m high
Page 6
~Door side panels -Glazing that can be mistaken for a doorway, this must also be marked (motifs). Steps greater than 3 risers require a landing before a doorway Waterproofing WC's and laundries require the wall/floor joint waterproofed for 25mm up the wall and onto the concrete floor. Lift off hinges may be needed on some toilet and bathroom doors (Clause 3.8.3.3) Brick Ties to be stainless steel or polymer <ikm from surf & <100m from canals etc. 1-10km from surf & 100m-1km from canals etc ties to be galvanised after manufacture (470g/m?). Other areas can be galvanised sheet steel. Internal bathrooms and toilets to be provided with an adequate system of mechanical ventilation. Smoke Alarms We recommend that smoke alarms be interconnected. It increases their effectiveness as an early warning (or lifesaving) device. Pool Fencing - It is worth remembering that the liability for maintaining the safety of a pool rests with the property owner. Direct access from the house to the pool enclosure is not allowed. Fireplaces require a 400mm Hearth for Free standing & 300mm for open & Insert type, this is required to extend 150mm either side and be 150mm above and combustible material (flooring etc), refer 3.7.3 BCA for further info. Applicant to ensure sufficient clearance between treatment plant/septic dispersal areas and new works. Retaining walls and fences - Retaining walls over 1 metre high need building approval and an engineer's certificate for the design. Fences can be up to 2 metres in height above natural ground level without needing approval. The combined height of a retaining wall and fence is not to exceed 2 metres above natural ground surface without approval by the Local Authority. Finished slab heights must be 150mm above finished ground level, or 50mm above sealed area, falls away from the building must be 50mm in 1m (this includes areas beneath landscaping stones). Ply Bracing at 6.0KN/m requires 13kN hold [email protected] centres, batten screw or strap provide only 4kN and are not acceptable, minimum 10mm bolted connection required. Termite protection required for all new works in ground contact to AS3660.1, any disturbed ground next to existing works to be re-treated to AS 3660.2, Basement or below ground Excavation may require special earth retention (sheet piling etc), before works are undertaken builder to consult with the foundation engineer to advise on requirements. Covenant approval is mot part of our assessment and the owner/applicant is responsible for obtaining and being consistent with this consent, refer to contract of purchase for details. Sediment And Erosion Control Measures should be put in place before any site works occur. Runoff from building sites, which carries sand, sift, and clay, is a major contributor to the degradation of the creeks and waterways. Failure to contro! such runoff is an offence under the Environment Protection Act (EPA) for which on-the-spot fines apply. Contaminated runoff is also responsible for clogging stormwater drains, thereby reducing their effectiveness and causing localised flooding. « Acid Sulphate Soils. Acid Sulphate Soils occur predominantly on coastal lowlands with elevations, or excavations below 5.0 m AHD. Please be advised that the onus is on the owner to seek a determination on whether or not the proposal will have any impact on acid sulphate soils. Under the Environment Protection Act 1994 (EPA), all responsible and practicable measures should be taken to avoid the risk of environmental harm. Noise restrictions: No audible noise permitted: * 6.30pm to 6.30am — Monday to Saturday. « Sundays and public holidays. Vehicle Crossovers, Prior to placing concrete an inspection to be booked with Gold Coast City Council by phoning 55828184 and quoting the preliminary permit number Existing. Reactive Clay sites, Refer to attached detail for recommended guidelines for Sanitary and storm water installations on reactive clay sites, These can also be accessed at www.bsa.ald.gov.au under builder’s technical information, BA21406
Page 7
20!» fon Gold Coast Building Approvals = 9/1 Nerang St, Nerang QLD 4211 PO BOX 1019, Nerang QLD 42114 PH: (07)5596 1308 F: (07) 5596 1302 ~ Company or Personal Name | Name of Representative - Cover DnSTALLATIONS Fiyrto are Roaary 3 | - all Address Contact Details Sco foRr Quo 45 FOK (p71) SS4aiIS 73> : Company or Personal Name Name_of Representative ss Cour Txstatatons Fay er autKoartey . z 3 Address: 'f different to above Contact Details ig g cs <2 & Phone: (07) SS4/S 730 ) S Above Fax (07) SS41¢ 73> Com Personal ‘ N fR ; sas Tan ieasueien Tet ik a. ee z. = Ta Cake te Monde x sade aiid z | Address: Contact Details = | Si HASTircs Strat Phone pr SS maureen 746 ) : 7 = | Project Address: —. paatines ST ” | INOooSA QO 4567 g S | Value of work Real Property Description. | 3 : 3 50, S50. 5% ola etc) = Site Area: 6 Bu 148 2 Ete Pan Aer. | ine Const Regional Gourd! CFEC CEREKE SS Makin Sekcas (ook 11693>) ? Pau McHenry is authorized under the Integrated Planning Act 1997 (QLD) to undertake the work of a private z The chent nas requested Paul McHenry to provide Building certification services in respect of the Building work at the project address. ae Paul McHenry will provide to the Client the services in respect of the project to receive assess and decide the on cremate na ont dated as per agreed fee for Professional Cartifying services as indicated on the fee proposal. agreement constitutes the engagement in writing required under the IPA (Section 5.3.9) oooh Mettemny or delegate is authorized by the owner/applicant to sign forms & documents to facilitate statutory SIGNED by or on behaif of the Owner a2 a) ths the owner or authorized representative) candy 2s/i/dor Saint name of signatory’ Renker Acwrumberitacompany.___/ 37 S8/ 77 Fee H 1 P® Horny - o4o> S34240 é I g3) | OFT BEE Manbraee Doorn s (O-tt3>! buns St. > hans Str fie " ; BSA ee we PT
Page 8
NOTE:
Inspection Certificate / Aspect Certificate / QBSA
Licensee Aspect Certificate
This form is to be used for the purposes of section 10(c) and 239 of the Building Act 1975 and/or
16
sections 32, 35B, 43, 44 and 47 of the Building Regulation 2006.
1. Indicate the type of certificate
Inspection Certificate for
The stages of assessable building work are
listed in section 24 of the Building Regulation
2006 or as conditioned by the building Stage of building work (for single detached class 1a or class 10 building or structure)
certifier. (indicate the stage) Final
An aspect of building work is part of a stage
(e.g. waterproofing). Aspect of building work
(indicate the aspect) _______________________________________________
QBSA Licensee Aspect Certificate
Scope of the work
Scope of the work covered by the licence class under the Queensland Building Services Authority
Regulation 2003 for the aspect being certified, eg scope of work for a waterproofing licence is “installing
waterproofing materials or systems for preventing moisture penetration”. An aspect being certified may
include “wet area sealing to showers”.
Note: Termite Management System not to be breached or the warranty will become void.
Shade Sails Only
2. Property description Street address (Include no., street, suburb / locality & postcode)
The description must identify all land the
subject of the application.
52 Hastings Street
The lot & plan details (eg. SP / RP) are NOOSA HEADS State: QLD Postcode: 4567
shown on title documents or a rates notice.
If the plan is not registered by title, provide Lot & plan details (Attach list if necessary)
previous lot and plan details. L6 BUP4745
In which local government area is the land situated?
Noosa/Terwanton
3. Building description Building/structure description Class of building / structure
Shade Sails Class 10
4. Description of component/s Components certified
certified
Clearly describe the extent of work covered Final
by this certificate, e.g. all structural aspects of
the steel roof beams.
LOCAL GOVERNMENT USE ONLY
Date Reference Approved Form 16
Received: Number/s: Version 3, 11/09
Page 9
(Form 16 continued…) page 2 of 2
5. Basis of certification Basis of certification
Detail the basis for giving the certificate and
the extent to which tests, specifications, rules, As visual inspection
standards, codes of practice and other
publications, were relied upon.
6. Reference documentation Reference documentation
Clearly identify any relevant documentation,
e.g. numbered structural engineering plans.
Building approval documentation
WD202
1001
3101 to 3114
7. Building certifier reference Building certifier reference number Development approval number
number and development approval
number 21406
8. Building Certifier or competent Name (in full)
person details
Paul McHenry
A competent person must be assessed as
competent before carrying out the inspection. Company name (if applicable) Contact person
The builder for the work cannot give a stage
certificate of inspection. Gold Coast Building Approvals As above
A competent person is assessed by the Phone no. (business hours) Mobile no. Fax no.
building certifier for the work as competent to
practice in an aspect of the building and (07) 5596 1308 0402 534 290 (07) 5596 1302
specification design, because of the Email address
individual’s skill, experience and
qualifications. The competent person must be [email protected]
registered or licensed under a law applying in
the State to practice the aspect. Postal address
If no relevant law requires the individual to be PO Box 1019
licensed or registered, the certifier must
assess the individual as having appropriate NERANG State: QLD Postcode: 4211
experience, qualifications or skills to be able
to give the help. Licence class Licence number
If the chief executive issues any guidelines Assistant Building Surveyor A707778
for assessing a competent person, the
building certifier must use the guidelines Date approval to inspect received from building certifier
when assessing the person.
12/12/2012
9. Signature of building certifier,
competent person or QBSA Signature Date
licensee
Note: A building certifier must sign this form
for temporary swimming pool fencing under
section 239(2)(b) of the Building Act 1975. 13/12/2012
Page 10
Final inspection certificate single detached class 1a
buildings; and Class 10 buildings or structures. 21
NOTE: Please use Form 17 for final certification of swimming pools and swimming pool fences.
1. Owner details Owner Name (in full)
If the owner is a company, a
contact person must be shown. Belmondos PTY LT T/A CAFÉ LE Monde
All correspondence will be Company name (if applicable) Contact person
mailed to this address.
As Above Ryan Taymor
Phone no (business hours) Mobile no Fax no
(07) 5591 5730
Email address
Postal address
46 Marqarer Street
SOUTHPORT State: QLD Postcode 4215
2. Property description Street address (Include no., street, suburb/locality & postcode)
The description must identify all
land the subject of the 52 Hastings Street
application.
The lot & plan details (eg. SP /
NOOSA HEADS State: QLD Postcode 4567
RP) are shown on title Lot & plan details (Attach list if necessary)
documents or a rates notice.
If the plan is not registered by L6 BUP4745
title, provide previous lot and
In which local government area is the land situated?
plan details.
Noosa/Terwanton
3. Building description Building description Class of building / structure
Shade Sails Class 10
4. Building certifier Building certifier reference number Development approval number
reference number /
approval number 21406
5. Performance Standards Performance requirements
If the building work uses a
performance based solution, Note: Termite Management System not to be breached or the warranty will become void.
list the performance
requirements used.
Shade Sail Only
OFFICE USE ONLY
Date Reference Approved Form 21
Received: Number/s: Version 2, 02/08
Page 11
(Form 16 continued…) page 2 of 2
6. Certification I certify that on an inspection carried out in accordance with best industry practice, the building work for
This form must be used by the above building or structure was inspected and complies with the building approval or certificates of
building certifiers to certify
compliance of single detached inspection were accepted from competent persons at the following stages of the construction.
class 1a buildings and class 10
buildings or structures Inspection type Date of inspection Date of certificate
(excluding swimming pools and
swimming pool fences) in Final 12-Dec-12 13-Dec-12
accordance with section 32(3)
of the Building Regulation
2006.
The building certifier must give
both to the owner and
assessment manager a copy of
the final inspection certificate.
Under section 21 of the
Building Regulation 2006 only a
building certifier must sign a
certificate of inspection for the
Foundation and Excavation
stage and the Final Inspection
certificate.
Dated this Thursday 13 Day of: December Year: 2012
7. Building Certifier Name of building certifier (In full) Licence no
Paul McHenry A707778
Signature Date
13/12/2012
Postal address
PO Box 1019
NERANG State: QLD Postcode: 4211
Phone no Mobile no Fax no
(07) 5596 1308 0402 534 290 (07) 5596 1302
Used in these records
Appendix D - 52 Hastings Street, Noosa Heads - Change Application 17.1.19.pdfRelated documentApplication case desk ↗