Specific Outcomes Probable Solutions Comments
a) results in a building scale that is application approval process in
compatible with surrounding accordance with QDC, BCA and
development; Council’s requirements at the time
b) does not present an appearance of of lodgement.
bulk to adjacent properties, roads or
other areas in the vicinity of the site;
c) maximises the retention of existing
vegetation and allows for soft
landscaping between buildings;
d) allows for adequate area at ground
level for outdoor recreation,
entertainment, clothes drying and other
site facilities; and
e) facilitates onsite stormwater
management and vehicular access.
O7 Site cover—
a) for a class 1 or class 10a building
within a Detached Housing Zone, does
not exceed—
i. for a single storey building -
50%; or
ii. for a building of 2 or more
storeys - 50% on the ground
floor and 30% for the upper
storey(s), or 40% for all storeys
for a building of 2 or more
storeys;
b) for other classes within a Detached
Housing Zone does not exceed—40%;
c) for the Semi-Attached Housing Zone
does not exceed 40%; or
d) for the Attached Housing Zone does
not exceed 40%.
O8 For Multiple Housing Type 2
development has a maximum plot ratio
of 0.45:1.
O9 For Multiple housing Types 3 or 4,
Visitor accommodation Type 4 or the
accommodation unit component of an
Entertainment and dining business
Type 3— the maximum gross floor area
is equivalent to the maximum allowable
population in persons multiplied by
40m².
O10 For the Neighbourhood Centre
Zone and the Business Centre Zone the
maximum plot ratio does not exceed—
a) 0.8:1 for the first 2,000m² of site
areas; plus
b) 0.3:1 for the balance of the site areas
in excess of 2,000m².
Flooding and drainage S11.1 For new buildings or structures or O11 - Complies. Reference is made
O11 Buildings and other works are additions of more than 50m2 gross floor to the requirements of the current
designed and sited to— area to an existing building or structure, conditions 68 to 73 with respect to
a) provide flood free access to premises floor levels for habitable rooms are— possible flooding.
and flood free habitable areas; a) for areas where minimum floor levels
JFP Ref: M1775 REV. A Page 11
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-07-04_Request Extension to Currency Period_FINAL.pdfRelated documentApplication case desk ↗
About this file
- File size
- 880 KB (small file)
- File type
No other editions are linked here.