SITE BOUNDARY SITE BOUNDARY
Ceiling to have a resistance to the Ceiling to have a resistance to the
incipient spread of fire of not less incipient spread of fire of not less
than 60 minutes than 60 minutes
SF3 20.00°
SF3 SF3
20.00° 20.00°
TERRACE TERRACE BED 1 BED 1
PB PB
CH 3,000.0 CH 3,000.0 CH 2,700.0 CH 2,700.0
CH 2,700.0 SF1 CH 2,700.0 SF1
PB PB
BED 1 BED 1
SIT
SIT
EB
EB
SF3 20.00°
OU
OU
6,410
ND
ND
CH 2,400.0 CH 2,400.0 BH BH
AR
AR
BH BH CH 2,400.0 CH 2,400.0
Y
Y
MRPB LIVING MRPB LIVING ENS ENS
BULKHEAD
BULKHEAD
CH 2,400.0 CH 2,400.0 CH 2,400.0 CH 2,400.0
ENS ENS MRPB MRPB
SERVICES SERVICES
PB PB SF1
BH BH BH BH BH BH CH 2,500.0 BH BH CH 2,500.0
MRPB CH 2,700.0 MRPB CH 2,700.0 CH 3,000.0 BTH BTH
CH 2,400.0 CH 2,400.0 CH 2,400.0 SF3 CH 2,400.0 SF3
CH 2,400.0 DINING CH 2,400.0 DINING CH 2,400.0 CH 2,400.0 SF3 20.00° SF3 20.00°
PB PB PB PB
BTH BTH MRPB MRPB
BH 400 BH 400 BH BH
BULKHEAD BULKHEAD
BULKHEAD
CH 2,400.0
CH 2,400.0 2,909 CH 2,400.0 BH BH BED 1
BH BH 2,910 CH 2,400.0 CH 2,400.0
PB CH 2,700.0
KITCHEN KITCHEN PB
2,647
2,647
CH 2,400.0 CH 2,400.0 CH 2,700.0
BED 2 KITCHEN BED 2 KITCHEN BED 2 BED 2
LIVING
CH 2,700.0 CH 2,700.0 CH 2,700.0 CH 2,700.0
PB PB PB DINING PB DINING
ENS
KITCHEN CH 2,700.0 CH 2,700.0
CH 2,400.0
PB PB MRPB
SF3
20.00° BTH PASSAGE
OFC 6 6 BULKHEAD
CH 2,400.0 CH 2,700.0
OFC PDR SF3
LIVING LIVING MRPB PB
RAKED 20.00°
0.00°
12.50°
SF1
SF1
MRPB
CH 2,400.0
BULKHEAD
SF1 20.00°
VOID VOID
OFC SF2
CARPORT CARPORT
GARAGE ENTRY
CH 3,000.0 CH 3,000.0 BED 2
CH 2,400.0
SF2 SF2 VOID STAIRS CH 2,700.0
PB
SHS PB
BALCONY BALCONY SF1 12.50°
CH 2,700.0 CH 2,700.0
SF2 SF2 SF2 SF1 SF1 SF1 12.50°
SF1
SF2
SF2 9.00°
LP LP
LP LP
BUILDING 1 GROUND LEVEL RCP BUILDING 1 UPPER LEVEL RCP
Scale 1:100 Scale 1:100
Notes:
B L A C K Project: Drawing Title: Project No. Drawn By Drawing No.
Rev Date Description Use figured dimensions in preference to scale. Contact information:
1 28/11/2024 BUILDING APPROVAL ISSUE All dimensions to be varified and checked on
2 13/12/2024 BUILDING APPROVAL RFI ISSUE site. These designs, drawings, specifications
PO Box 781 Tewantin Q 4565 79 - 83 Eumundi Noosa Road B1 - REFLECTED CEILING 202327 PT WD.1.02
Architect Registration # 5386 QLD
and the copyright thereof are the property of For CAPITAL PRUDENTIAL
4 28/02/2025 CONSTRUCTION ISSUE
Blackwood and must not be used, retained or W O O D Ph: 0416 037 424 PLANS
5 10/03/2025 Concil AMdendment Issue copied without the written authority of [email protected] 79 - 83 EUMUNDI NOOSA ROAD & 26 Scale Date Project Stage Revision
6 25/03/2025 Pools & Landscape Calculation Revised Blackwood. a r c h i t e c t u r e & d e s i g n www.blackwoodarchitecture.com.au HEADLAND DRIVE, NOOSAVILLE QLD 4566 1:100 @ A1 25/03/2025 Building Approval 6
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Updated Plans RFI Submission B1 B2 & B3 (rec. 26.03.25).pdfRelated documentApplication case desk ↗
About this file
- File size
- 13.0 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.