Generally in Accordance Approved Plans - MCU18/0006.01
Plans and drawings: the text below has words only, no drawings.
CAL W (3) SYZ R (2) CRI ped (2)
ANDREW GOLD LANDSCAPE ARCHITECTURE
BAN CC (5) LOM KB (3) Ghg
PO BOX 5220
MT GRAVATT EAST
QLD 4122
T 07 3420 0006
M 0405 389 243
E [email protected]
WES WG (2) WES WG (3)
T15 PROPOSED 1800mm TIMBER SCREEN FENCE LEGEND
WES Z (6) T14 By builder
LOM ver (12)
T16
LOM KB (4) EXISTING / PROPOSED TURFED AREAS
Refer Specification Notes
600
300
POOL (3x4)
PROPOSED 1800mm TIMBER SCREEN FENCE T13 By builder PROPOSED HARDSTAND
By builder Bi Refer Architectural drawings
PROPOSED POOL FENCE
By builder
POOL (3x4) PROPERTY BOUNDARY
By builder T12 As taken from Survey drawings
PROPOSED POOL FENCE
By builder 600
EXISTING CONTOURS
As taken from Survey drawings
GATE GATE
300
CAR gla (2) PROPOSED GARDEN EDGE
+ RL 40.0 + RL 40.0 T11 Refer Specification Notes and Detail
39.0
RETAINING WALL
1000 Pt
1000 By builder, 1800mm timber screen fence on top
WES Z (2) BAN CC (4)
PROPOSED TIMBER SCREEN FENCE
1800mm high, by builder
400
400
F. GR. L 40.0 PROPOSED POOL FENCE
Ghg F. SL. L 40.3 By builder
EXISTING TREE - RETAINED
- Refer Existing Tree Schedule
GENERALLY IN ACCORDANCE EXISTING TREE - REMOVED
LOM KB (6) LOM KB (6)
MCU18/0006.01 Refer Existing Tree Schedule
1400
NOOSA COUNCIL 1400
PROPOSED SHADE / SCREEN TREES
1000
1000
27 JUNE 2019 Refer Planting Schedule
-
PROPOSED SHRUBS / GROUNDCOVERS
Refer Planting Schedule
PROPOSED BIN LOCATION
As shown
LOM ver (25)
LOM ver (25)
CLOTHESLINE
Attached to fence
T9 EXISTING SEWER
As taken from Survey drawings
T10
PROPOSED ROOFWATER LINE
T8 Refer Engineering drawings
GRATED STORMWATER INLET
40.0 Refer Hydraulic Engineering drawings
PROPOSED RETAINING WALL
By builder CAS CI (1) GRE lan (1) PROPOSED RETAINING WALL
1800mm timber screen fence on top By builder
GRE lan (1) CAS CI (1) 1800mm timber screen fence on top
Bi
Bi
LOM ver (3) LOM ver (3)
CRI ped (2) CRI ped (1)
CAR gla (1)
T6 T7 CAR gla (1)
GRATED STORMWATER INLET GRATED STORMWATER INLET A 27/02/18 SUBMISSION TO NSC
Refer Hydraulic Engineering drawings Refer Hydraulic Engineering drawings
ISSUE DATE REASON
THIS DRAWING HAS BEEN PREPARED WITH ALL CARE FROM BASE INFORMATION AVAILABLE
T4 AT THE TIME OF PREPARATION. ALL EXISTING AND RETAINED ELEMENTS ARE SHOWN
T1 T2 T3 INDICATIVELY ONLY. THE LOCATION OF THESE ELEMENTS ARE BASED FROM SURVEY
INFORMATION. ALL PLANS AND DETAILS ARE TO BE READ IN CONJUNCTION WITH ALL
41.0 RELEVANT CONSULTANT'S DOCUMENTATION PACKAGES, INCLUDING (BUT NOT LIMITED TO)
ARCHITECTURAL, CIVIL, STRUCTURAL, HYDRAULIC, ELECTRICAL, LIGHTING AND SIGNAGE
DOCUMENTATION. ALL ABOVE AND BELOW GROUND SERVICE LOCATIONS ARE SHOWN
INDICATIVELY. REFER TO THE RELEVANT ENGINEERS DRAWINGS AS REQUIRED. ALL
T5 DIMENSIONS ARE TO BE VERIFIED ON SITE.
GRAPHIC SCALE (m) 1:100 @A1
0 1 5
WES Z (2) Ca
WES Z (2) PROPOSED MULTI-UNIT DWELLING
Ca
10 HILL STREET, SUNSHINE BEACH
VISUALLY PERMEABLE FRONT FENCE PROPOSED DRIVEWAY CROSSOVER
Rendered brick piers and powder-coated
aluminum panels
Refer Engineering drawings and NSC Standard drawings LANDSCAPE PLAN
NOTE FOR COUNCIL: Combined 2m landscape
buffer more effective than divided landscape JOB NUMBER SHEET No. ISSUE DRAWN BY
buffer with the requested 1m setback to fence as
requested in NSC
18.018 1 A AG/NB/AL
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Generally in Accordance Approved Plans - MCU18/0006.01Related documentApplication case desk ↗
About this file
- File size
- 1.2 MB (small file)
- File type
No other editions are linked here.