1077 Malisano ISSUED FOR DA 17-4-14 · 51994.1390.02

Attached to the e-mail 51994.1390.02 (TPC 2739) -Permissible Change to TPC 2739.

of 15

Text shows just the words. Original shows the document exactly as it was published.

                                                LOT No:   0
                                                SP No:    108797
                                                GENERAL NOTES
                                                1. ALL WORKMANSHIP SHALL BE CARRIED OUT TO THE BEST TRADE
                                                STANDARDS AND MATERIAL FIXED IN ACCORDANCE WITH SPECIFIED
                                                DETAIL AND MANUFACTURER'S RECOMMENDATIONS.

                                                2. THE FOLLOWING DOCUMENTS FORM PART OF THE
                                                DOCUMENTATION FOR THIS PROJECT:
                                                A.S. 1684.2 RESIDENTIAL TIMBER FRAMED CONSTRUCTION CODE

                                                3. THE ABOVE DOCUMENTS SHOULD BE KEPT ON SITE DURING
                                                CONSTRUCTION ALONG WITH THE COPY OF THE LOCAL APPROVED
                                                PLANS AND SPECIFICATIONS. CONSTRUCTION MUST NOT VARY FROM
                                                THE ABOVE DOCUMENTATION WITHOUT WRITTEN APPROVAL FROM
                                                THE OWNER AND THE LOCAL AUTHORITY.

                                                4. FIGURED DIMENSIONS TAKE PRECEDENCE OVER SCALING OFF
                                                PLAN. DO NOT SCALE. ANY DISCREPANCIES FOUND BUT THE BUILDER
                                                / OWNER SHOULD BE BROUGHT TO THE ATTENTION OT THE
                                                DESIGNER PRIOR TO CONSTRUCTION OR FABRICATION OF ANY ITEM.

                                                5. RETAIN ALL EXISTING VEGETATION AND MATURE TREES WHERE
                                                POSSIBLE.

                                                6. STRUCTURE SHALL NOT EXCEED 7.9m ABOVE NATURAL GROUND.

                                                7. CHECK ALL DIMENSIONS OF WORKS ON SITE PRIOR TO
                                                COMMENCEMENT OF CONSTRUCTION OR FABRICATION OF ANY ITEM.
                                                REFER DISCREPANCIES TO DESIGNER BEFORE CONSTRUCTION OR                                                                         LOCATION PLAN
                                                FABRICATION.

                                                8. COMPLY WITH THE BUILDING CODE OF AUSTRALIA (BCA),
                                                RELEVANT AUSTRALIAN STANDARDS AND LOCAL COUNCIL BUILDING
                                                CODES.                                                                                                                        45° 47' 30"
                                                9. REINF. CONCRETE CROSSOVER TO STREET TO BE IN                                                                                 33.062 m




                                                                                                                                                                                                  2034




                                                                                                                                                                                                                               2266
                                                ACCORDANCE WITH THE LOCAL AUTHORITIES DETAILS AND
                                                SPECIFICATION.

                                                10. TV ANTENNAE LOCATION TO BE VERIFIED ON SITE BY INSTALLER                                     F
                                                                                                                                                 E
                                                                                                                                                           303° 4
                                                                                                                                                             16.94




                                                SITE NOTES




                                                                                                                                                                                                                                                                                                PARK CRES
                                                                                                                                                                 2' 00"
                                                                                                                                                                  8m




                                                DRAINAGE:
                                                ALL HOUSEHOLD SEWERAGE AND WASTE TO BE DISCHARGED TO
                                                SEWER SYSTEM.                                                                                    D




                                                                                                                                                                                                                                                                  138° 23' 30"
                                                                                                                                                                                                                                                                                 17.894 m
                                                SEWER LINE LOCATION TO BE VERIFIED ON SITE AND NO PART OF                                        C
                                                THE PROPOSED RESIDENCE TO BE WITHIN 1500mm OF EDGE OF
                                                SEWER PIPE
                                                                                                                                                                               2330

                                                SURFACE WATER:
                                                SURFACE WATER TO BE DISCHARGED BY NATURAL FALL OF THE
                                                GROUND AND CUTOFF DRAINS.
                                                                                                                                                 B
                                                                                                                                                 A
                                                ALL RAINWATER FROM ROOF DISCHARGE SHALL BE DRAINED AT
                                                LEAST 3.0m FROM THE BUILDING FOUNDATION, OR TO LOCAL
                                                AUTHORITY REQUIREMENTS.                                                                                                                 228° 23' 30"
                                                STORMWATER DRAINAGE NOTES                                                                                                                28.730 m
                                                1. DP - 90mm DIA DOWNPIPES TO STORMWATER PIPES 100mm MIN
                                                COVER. 1 IN 100 MIN FALL.

                                                2. ONE DOWNPIPE PER 12m OF GUTTER. REDUCE BY 1m FOR EACH                                                                                                               1                    2
                                                BEND IN GUTTER.
                                                                                                                                                                                        SITE PLAN                                                                                   N
                                                3. STORMWATER PIPES SHALL BE CONNECTED TO KERB AND
                                                CHANNEL TO LOCAL AUTHORITY REQUIREMENTS.                                                                                            1   1 : 200
                                                                                                                                                                                                                                                                                     O
                                                                                                                                                                                                                                                                                      RT
                                                                                                                                                                                                                                                                                            H
                                              REV    DATE                  DESCRIPTION                         SPECIFICATION NOTES                                                                                                                                                                          DRAWING TITLE

                                               A     17-4-14 ISSUED FOR DA                                     1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                             TEL: (07) 5455 3651                         SITE PLAN
                                                                                                                                                                                                                                                                                                                                                        A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                               READINGS
                                                                                                               2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                                               COMMENCING FABRICATION
                                                                                                               3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                                    RENOVATIONS                                                                 [email protected]
                                                                                                                                                                                                                                                                WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                                            DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                                               RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                               4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                     17-Apr-14     As
                                                                                                               HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                                            Paul Hindes     1077         10:12:03 AM   indicated
                                                                                                                                                                                    LOT 0 SP 108797                                                             QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                               5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                   DRAWING No                                 REVISION
                                                                                                               CONSTRUCTION
                                                                                                                                                                                                                                                                23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                               6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                               USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                                    FOR THE BODY CORPORATE OF 19 ON THE PARK          Exclusive Residential and Commercial Designs by Paul Hindes           DA01                                        A
Full text of the other 14 pages

Page 2

                                                                                                                                                                                      1                                        2


                                                                                                                                                                                   45° 47' 30"
                                                                                                                                                                                    33.062 m

                                                                                                                                                                                                                                                  TURNING AREA
                                                                                                                                                                                                                 UP
                                                    F

                                                    E


                                                                                                                                                                                      STORE UNIT 2




                                                                                                                                                             STAIR
                                                                                                                                                                                      GARAGE UNIT 2
                                                                                                                                                                                                                                                          DRIVEWAY
                                                    D

                                                                                                                                             STORE UNIT 1 LOBBY
                                                    C




                                                                                                                                                                                                                                                                                                                                PARK CRES
                                                                                                                                                                                      GARAGE UNIT 1




                                                                                                                                                                                                                                                                               138° 23' 30"
                                                                                                                                                                                                                                                                                              17.894 m
                                                                       303° 4
                                                                         16.94




                                                                                                                                                                                                      VISITOR PARKING
                                                                             2' 00"
                                                                              8m




                                                    B

                                                    A


                                                                                                                                                                                                                                                                   GATEHOUSE

                                                                                                                                                                                                                                           228° 23' 30"
                                                                                                                                                                                                                                            28.730 m




                                                                                                                                                               EXISTING LOWER FLOOR PLAN
                                                                                                                                                        1      1 : 100                                                                                  N
                                                                                                                                                                                                                                                         O
                                                                                                                                                                                                                                                          RT
                                                                                                                                                                                                                                                               H

                                              REV   DATE                  DESCRIPTION   SPECIFICATION NOTES                                                                                                                                                                    DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED             PROPOSED DUPLEX                                                            TEL: (07) 5455 3651                   EXISTING LOWER FLOOR
                                                                                                                                                                                                                                                                                                                                       A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                        READINGS
                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE                                                                                                                            PLAN
                                                                                        COMMENCING FABRICATION
                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                              RENOVATIONS                                                                [email protected]
                                                                                                                                                                                                                                         WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                               DRAWN                     PROJECT No   PLOT DATE        SCALE
                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF      19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                        17-Apr-14
                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                               Paul Hindes               1077         10:12:04 AM     1 : 100
                                                                                                                                                              LOT 0 SP 108797                                                            QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                             DRAWING No                                             REVISION
                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                         23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                              FOR THE BODY CORPORATE OF 19 ON THE PARK         Exclusive Residential and Commercial Designs by Paul Hindes     DA02                                                    A

Page 3

                                                                                                                                                                                      1                                        2




                                                                                                                                                                                                                 UP                                  TURNING AREA
                                                     F

                                                     E


                                                                                                                                                                                                STORE UNIT 2




                                                                                                                                                                                                                                                                                                                      PARK CRES
                                                                                                                                                      STAIR WELL
                                                                                                                                                                                     GARAGE UNIT 2

                                                    D                           A
                                                                               DA11
                                                                                                                                                                                                                                                     DRIVEWAY
                                                    C
                                                                                                                                                                                     GARAGE UNIT 1
                                                                                                                                               STORE UNIT 1




                                                                                                                                                                        NEW LOBBY                   VISITOR PARKING


                                                     B

                                                     A

                                                                                                                                                                                                                                   ENTRY PATH                       GATEHOUSE




                                                                                                                                                                                                                                                        N
                                                                                                                                                             PROPOSED LOWER FLOOR PLAN                                                                   O
                                                                                                                                                                                                                                                          RT
                                                                                                                                                      1      1 : 100
                                                                                                                                                                                                                                                               H


                                              REV   DATE                  DESCRIPTION   SPECIFICATION NOTES                                                                                                                                                                    DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                             TEL: (07) 5455 3651                   PROPOSED LOWER FLOOR
                                                                                                                                                                                                                                                                                                                              A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                        READINGS
                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE                                                                                                                            PLAN
                                                                                        COMMENCING FABRICATION
                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                             RENOVATIONS                                                                 [email protected]
                                                                                                                                                                                                                                         WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                               DRAWN           PROJECT No   PLOT DATE        SCALE
                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                               17-Apr-14
                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                               Paul Hindes     1077         10:12:05 AM      1 : 100
                                                                                                                                                             LOT 0 SP 108797                                                             QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                             DRAWING No                                    REVISION
                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                         23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                             FOR THE BODY CORPORATE OF 19 ON THE PARK          Exclusive Residential and Commercial Designs by Paul Hindes     DA03                                           A

Page 4

                                                                                                                                                                                                                       UP


                                                     F
                                                     E
                                                                                                                                                             DECK


                                                                                                                              BED 3
                                                                                                                                                                            KITCHEN


                                                                                                                                                             STAIRWELL

                                                                                                                                                                                                UNIT 1
                                                     D
                                                                                                     BATH                                                        HALL                           LIVING / DINING

                                                     C

                                                                                                                WC




                                                                                                                                                                                                                                                                                                                              PARK CRES
                                                                                                                                                             ENS
                                                                                                                                                                                                                            TERRACE
                                                                                        UP
                                                                                                                            BED 2                                        BED 1



                                                                                                                                                        DECK
                                                     B
                                                     A




                                                                                                                                                                                        1                                            2



                                                                                                                                                                                                                                                               N
                                                                                                                                                                                                                                                                O
                                                                                                                                                                                                                                                                 RT
                                                                                                                                                             EXISTING MID-FLOOR PLAN                                                                                  H
                                                                                                                                                      1      1 : 100



                                              REV   DATE                  DESCRIPTION   SPECIFICATION NOTES                                                                                                                                                                       DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                                TEL: (07) 5455 3651                   EXISTING MID-FLOOR PLAN
                                                                                                                                                                                                                                                                                                                             A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                        READINGS
                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                        COMMENCING FABRICATION
                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                             RENOVATIONS                                                                    [email protected]
                                                                                                                                                                                                                                            WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                  DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                  17-Apr-14
                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                  Paul Hindes     1077         10:12:05 AM   1 : 100
                                                                                                                                                             LOT 0 SP 108797                                                                QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                DRAWING No                                 REVISION
                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                            23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                             FOR THE BODY CORPORATE OF 19 ON THE PARK             Exclusive Residential and Commercial Designs by Paul Hindes     DA04                                       A

Page 5

                                                                                                                                                                                                                                                  UP


                                                    F
                                                    E
                                                                                                                                                                                   BALCONY
                                                                                                                                                                                                             STUDY
                                                                      PROPOSED ADDITION TO                                                                                                                   EXTENSION
                                                                                                                                                                                                                                 NEW KITCHEN                                          NOTE: FLOOR AREAS
                                                                      BUILDING OUTSIDE OF
                                                                      CURRENT BUILDING ENVELOPE                                                                                                                                   EXTENSION                                           EXTENDED ONTO
                                                                      SHOWN HATCHED                                                                 BED 3                                          MEDIA                                                                              EXISTING BALCONY
                                                                                                                                                                                                                                                                                      SHOWN TONED




                                                                                                                                12
                                                                                                    30




                                                                                                                                  14
                                                                                                  31

                                                                                                                                                                                   STAIRWELL
                                                                                                                     BATH
                                                                                3639

                                                                                                         WC
                                                                                                                                                                                                                           UNIT 1
                                                    D          A
                                                              DA11
                                                                                                                                                                                                                         LIVING / DINING
                                                                              2304
                                                    C
                                                                                                                                     LDY




                                                                                                                                                                                                                                                                                                                                                         PARK CRES
                                                                                                                                                                               ROBE
                                                                                     NEW STEEL SPIRAL                                                                                                                                                   TERRACE
                                                                                     STAIR TO BE USED
                                                                                     AS ALTERNATIVE       UP
                                                                                     EMERGENCY EXIT                                                BED 4
                                                                                     FROM UNIT 2                                                                                                BED 1


                                                                                                                                                                                   ENS                     BED 1
                                                                                                                                                                                   EXTENSION
                                                                                                                                                                                                           EXTENSION
                                                    B
                                                    A




                                                                                                                                                                                                                   1                                            2

                                                                                                                                                                                                                                                                                         N
                                                                                                                                                                                                                                                                                          O
                                                                                                                                                                                    PROPOSED MID-FLOOR PLAN                                                                                RT
                                                                                                                                                                                                                                                                                                H
                                                                                                                                                                           1         1 : 100


                                              REV   DATE                  DESCRIPTION                         SPECIFICATION NOTES                                                                                                                                                                             DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA                                     1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED              PROPOSED DUPLEX                                                                    TEL: (07) 5455 3651                   PROPOSED MID-FLOOR
                                                                                                                                                                                                                                                                                                                                                           A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                              READINGS
                                                                                                              2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE                                                                                                                                     PLAN
                                                                                                              COMMENCING FABRICATION
                                                                                                              3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                                     RENOVATIONS                                                                        [email protected]
                                                                                                                                                                                                                                                                        WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                                              DRAWN           PROJECT No   PLOT DATE       SCALE
                                                                                                              RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                              4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF       19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                      17-Apr-14
                                                                                                              HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                                              Paul Hindes     1077         10:12:07 AM     1 : 100
                                                                                                                                                                                     LOT 0 SP 108797                                                                    QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                              5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                      DRAWING No                                   REVISION
                                                                                                              CONSTRUCTION
                                                                                                                                                                                                                                                                        23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                              6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                              USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                                     FOR THE BODY CORPORATE OF 19 ON THE PARK                 Exclusive Residential and Commercial Designs by Paul Hindes     DA05                                         A

Page 6

                                                    F
                                                    E
                                                                                                                                                              DECK


                                                                                                                            BED 2                                             KITCHEN


                                                                                                                                                           STAIRWELL                             DINING              TERRACE

                                                                                                                                                                                                 UNIT 2
                                                    D
                                                                                                    BATH                                                  HALLWAY
                                                    C




                                                                                                                                                                                                                                                                                                                         PARK CRES
                                                                                                                                                                                                 LIVING
                                                                                            DECK
                                                                                                                                     ENS

                                                                                                                                                                   BED 1
                                                                                                              WIR



                                                    B
                                                    A




                                                                                                                                                                                            1                                 2

                                                                                                                                                                                                                                                       N
                                                                                                                                                                                                                                                        O
                                                                                                                                                                                                                                                         RT
                                                                                                                                                                   EXISTING UPPER FLOOR PLAN                                                                  H
                                                                                                                                                            1      1 : 100


                                              REV       DATE                  DESCRIPTION     SPECIFICATION NOTES                                                                                                                                                             DRAWING TITLE

                                               A        17-4-14 ISSUED FOR DA                 1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                      TEL: (07) 5455 3651                   EXISTING UPPER FLOOR
                                                                                                                                                                                                                                                                                                                               A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                              READINGS
                                                                                              2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE                                                                                                                     PLAN
                                                                                              COMMENCING FABRICATION
                                                                                              3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                   RENOVATIONS                                                          [email protected]
                                                                                                                                                                                                                                        WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                              DRAWN           PROJECT No   PLOT DATE           SCALE
                                                                                              RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                              4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                        17-Apr-14
                                                                                              HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                              Paul Hindes     1077         10:12:07 AM         1 : 100
                                                                                                                                                                   LOT 0 SP 108797                                                      QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                              5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                      DRAWING No                                       REVISION
                                                                                              CONSTRUCTION
                                                                                                                                                                                                                                        23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                              6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                              USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                   FOR THE BODY CORPORATE OF 19 ON THE PARK   Exclusive Residential and Commercial Designs by Paul Hindes     DA06                                             A

Page 7

                                                                                                       45° 47' 30"
                                                                                                        33.062 m




                                                                                                                                                                                                                                                  2266




                                                                                                                                                                                                                                                                             2353
                                                    F
                                                    E                                                                                                                                     DECK
                                                               303° 4




                                                                                                                                                                                                                  NEW STUDY
                                                                 16.94




                                                                              PROPOSED ADDITION TO                                                                                                                EXTENSION                                                                     NOTE: FLOOR AREAS
                                                                              BUILDING OUTSIDE OF                                                                                                                                             NEW KITCHEN                                       EXTENDED ONTO
                                                                     2' 00"




                                                                              CURRENT BUILDING ENVELOPE                                                                                                                                         EXTENSION
                                                                                                                                                                                                      NEW MEDIA
                                                                      8m




                                                                              SHOWN HATCHED                                                                                                                                                                                                     EXISTING BALCONY
                                                                                                                                   12
                                                                                                       50                            14            BED 2                                                                                                                                        SHOWN TONED
                                                                                                     30



                                                                                                                                                                                   STAIRWELL                                         DINING

                                                                                                                                                                                                                                     UNIT 2
                                                    D            A
                                                                DA11
                                                                                     2330                                                                                                 HALL
                                                                                                                                   BATH                                                                                              LIVING                    TERRACE
                                                    C
                                                                                                                                       LDY




                                                                                                                                                                                                                                                                                                                                                                               PARK CRES
                                                                                                                   WIR
                                                                                            NEW STEEL SPIRAL       EXTENSION
                                                                                            STAIR TO BE USED
                                                                                                                                                               ENS
                                                                                            AS ALTERNATIVE
                                                                                            EMERGENCY EXIT
                                                                                            FROM UNIT 2                                WIR                                                    BED 1
                                                                                                                                                                                                           BED 1
                                                                                                                                                                                                           EXTENSION


                                                    B
                                                    A




                                                                                                                                                                                                                                                                                                                          138° 23' 30"
                                                                                                                                                                                                                                                                                                                                         17.894 m
                                                                                                                                                                                                                              2457
                                                                                                                 228° 23' 30"
                                                                                                                     28.730 m




                                                                                                                                                                                                                        1                                                2


                                                                                                                                                                                                                                                                                                   N
                                                                                                                                                                                                                                                                                                    O
                                                                                                                                                                                           PROPOSED UPPER FLOOR PLAN                                                                                 RT
                                                                                                                                                                                      1     1 : 100
                                                                                                                                                                                                                                                                                                          H



                                              REV       DATE                  DESCRIPTION                            SPECIFICATION NOTES                                                                                                                                                                                  DRAWING TITLE

                                               A        17-4-14 ISSUED FOR DA                                        1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                                           TEL: (07) 5455 3651                   PROPOSED UPPER FLOOR
                                                                                                                                                                                                                                                                                                                                                                                      A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                                     READINGS
                                                                                                                     2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE                                                                                                                                          PLAN
                                                                                                                     COMMENCING FABRICATION
                                                                                                                     3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                                          RENOVATIONS                                                                               [email protected]
                                                                                                                                                                                                                                                                                    WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                                                          DRAWN                     PROJECT No   PLOT DATE           SCALE
                                                                                                                     RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                                     4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                                       17-Apr-14
                                                                                                                     HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                                                          Paul Hindes               1077         10:12:10 AM         1 : 100
                                                                                                                                                                                          LOT 0 SP 108797                                                                           QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                                     5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                           DRAWING No                                                 REVISION
                                                                                                                     CONSTRUCTION
                                                                                                                                                                                                                                                                                    23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                                     6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                                     USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                                          FOR THE BODY CORPORATE OF 19 ON THE PARK                       Exclusive Residential and Commercial Designs by Paul Hindes      DA07                                                        A

Page 8

                                                                                                                                                                                                                                       FE                                  D        C                                         BA

                                                                  AB                                   C           D                                                             EF
                                                                                                                                                                                                                                                                                                                                           PROPOSED NEW
                                                                                                                                                                                             EXISTING ROOF HOOD OVER                                                                                                                       ADDITION TO REAR
                                                                                                                                                                                             TERRACE TO BE REMOVED
                                                                                                                                                                                                                                                                                                                                           ROOF EXTENDED OVER
                                                                                                                                                                                                                                                                                                                                           DECK ADDITION
                                                                                                                                                                                             EXISTING GLASS SLIDING DOORS TO
                                                                                                                                                                                             BE RENEWED                                                                                                                                    NEW WALLS TO DECK
                                                                                                                                                                                                                                                                                                                                           ADDITIONS TONED
                                                                                                                                                                                                           Ceiling                                                                                                                                        Ceiling
                                                                                                                                                                                                        RL 37.230                                                                                                                                      RL 37.230
                                                                                                                                                                                             NEW GLASS SLIDING DOOR AND WALLS
                                                                                                                                                                                             TO NEW KITCHEN

                                                                                                                                                                                             NEW SAFETY GLASS HANDRAIL
                                                                                                                                                                                                          Level 3                                                                                                                                        Level 3
                                                                                                                                                                                                        RL 34.830                                                                                                                                      RL 34.830
                                                                                                                                                                                             NEW WINDOWS TO NEW KITCHEN

                                                                                                                                                                                             NEW SAFETY GLASS HANDRAIL


                                                                                                                                                                                                          Level 2                                                                                                                                        Level 2
                                                                                                                                                                                                        RL 31.920                                                                                                                                      RL 31.920

                                                                                                                                                                                                                                                                                                                                           NEW STEEL SPIRAL
                                                                                                                                                                                                                                                                                                                                           STAIR TO ACT AS
                                                                                                                                                                                                                                                                                                                                           EMERGENCY ESCAPE
                                                                                                                                                                                                                                                                                                                                           FROM UNIT 2
                                                                                                                                                                                                          Level 1
                                                                                                                                                                                                        RL 29.300
                                                                          ENTRY         GARAGE 1                         GARAGE 2


                                                                                   NEW ENCLOSED LOBBY WITH
                                                                                   GLASS DOOR AND SIDELIGHTS




                                                                EAST ELEVATION                                                                                                                                                      WEST ELEVATION
                                                            1   1 : 100
                                                                                                                                                                                                                                2   1 : 100




                                              REV   DATE                  DESCRIPTION                      SPECIFICATION NOTES                                                                                                                                                                                DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA                                  1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                                         TEL: (07) 5455 3651                   ELEVATIONS
                                                                                                                                                                                                                                                                                                                                                              A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                           READINGS
                                                                                                           2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                                           COMMENCING FABRICATION
                                                                                                           3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                                RENOVATIONS                                                                             [email protected]
                                                                                                                                                                                                                                                                        WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                                              DRAWN                PROJECT No   PLOT DATE     SCALE
                                                                                                           RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                           4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                                17-Apr-14
                                                                                                           HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                                              Paul Hindes          1077         10:12:13 AM   1 : 100
                                                                                                                                                                                LOT 0 SP 108797                                                                         QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                           5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                         DRAWING No                                      REVISION
                                                                                                           CONSTRUCTION
                                                                                                                                                                                                                                                                        23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                           6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                           USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                                FOR THE BODY CORPORATE OF 19 ON THE PARK                      Exclusive Residential and Commercial Designs by Paul Hindes     DA08                                            A

Page 9

                                                                                                                                                                                             1                               2

                                                                                                                                                                                                   NEW WINDOWS AND WALL TO
                                                                                                                                                                                                   EXTENDED BEDROOM




                                                    ROOF EXTENDED
                                                    OVER NEW DECK
                                                    EXTENSION                                                                                                                                                                                     Ceiling
                                                                                                                                                                                                                                               RL 37.230
                                                    NEW WALLS TO DECK
                                                                                                                                                                                                                                                                 NEW WINDOWS TO
                                                    EXTENSION
                                                                                                                                                                                                                                                                 RELOCATED KITCHEN




                                                                                                                                                                                  1000
                                                                                                                 OBSCURE                                                                                                                                         NEW SAFETY GLASS
                                                                                                                 GLASS                                                                                                                           Level 3         HANDRAIL

                                                                                                                                                                                                                                               RL 34.830
                                                    NEW STEEL SPIRAL
                                                    STAIR                                                                                                                                                                                                        NEW WINDOWS TO
                                                                                                                                                                                                                                                                 RELOCATED KITCHEN

                                                                                                                                                                                                                                                                 NEW SAFETY GLASS
                                                                                                                                                                                                                                                                 HANDRAIL
                                                                                                                         900




                                                                                                                                                                                                                                                 Level 2
                                                                                                                                                                                                                                               RL 31.920



                                                                             NEW WINDOWS TO ENSUITE

                                                                                                                                                                                                                                                 Level 1
                                                                             NEW WALL TO ENSUITE OVER                                                                                                                                          RL 29.300
                                                                             EXISTING DECK




                                                                                                                                                                                  SOUTH ELEVATION
                                                                                                                                                                             1     1 : 100




                                              REV   DATE                  DESCRIPTION                   SPECIFICATION NOTES                                                                                                                                                                       DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA                               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED                PROPOSED DUPLEX                                                            TEL: (07) 5455 3651                   SOUTH ELEVATION
                                                                                                                                                                                                                                                                                                                                             A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                        READINGS
                                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                                        COMMENCING FABRICATION
                                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                                 RENOVATIONS                                                                [email protected]
                                                                                                                                                                                                                                                            WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                                  DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF         19 PARK CRESCENT, SUNSHINE BEACH                                                                                                              17-Apr-14
                                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                                  Paul Hindes     1077         10:12:15 AM   1 : 100
                                                                                                                                                                                 LOT 0 SP 108797                                                            QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                DRAWING No                                 REVISION
                                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                                            23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                                 FOR THE BODY CORPORATE OF 19 ON THE PARK    Exclusive Residential and Commercial Designs by Paul Hindes          DA09                                       A

Page 10

                                                                                                                                                                 2                                                   1
                                                                                 NEW OBSCURE GLASS WINDOW




                                                                                                                                                                                                                                                                                                            ROOF EXTENDED
                                                                                                                                                                                                                                                                                                            OVER NEW DECK
                                                                                                              Ceiling                                                                                                                                                                                       EXTENSION
                                                                                                              RL 37.230




                                                                                                                                                                                                              1000
                                                                                 NEW WINDOWS TO                                                                                                                                                                                                             NEW WALLS TO BATHROOM
                                                                                 RELOCATED KITCHEN                                                                                                                                                                                                          EXTENSION




                                                                                                                                                                                              600




                                                                                                                                                                                                                                                                                        1500
                                                                                                                                                                                                              1100
                                                                                                                                                                             1000
                                                                                 NEW SAFETY GLASS




                                                                                                                                                                                              900
                                                                                 HANDRAIL                     Level 3
                                                                                                              RL 34.830
                                                                                                                                                                                                                                                                                                            NEW STEEL SPIRAL
                                                                                 NEW WINDOWS TO                                                                                                                                                                                                             STAIR




                                                                                                                                                                                                              1000
                                                                                 RELOCATED KITCHEN

                                                                                 NEW SAFETY GLASS




                                                                                                                                                                                                                                                                                        1500
                                                                                                                                                                                                              1100
                                                                                 HANDRAIL




                                                                                                                                                                                    900
                                                                                                              Level 2
                                                                                                              RL 31.920




                                                                                                              Level 1                                                                                                                      NEW WINDOWS TO STUDIES.
                                                                                                              RL 29.300                                                                                                                    EXISTING OPENINGS TO BE
                                                                                                                                                                                                                                           BLOCKED UP DOTTED




                                                                                                                                                                                 NORTH ELEVATION
                                                                                                                                                                       1            1 : 100




                                              REV   DATE                  DESCRIPTION                       SPECIFICATION NOTES                                                                                                                                                                     DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA                                   1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED                PROPOSED DUPLEX                                                          TEL: (07) 5455 3651                   NORTH ELEVATION
                                                                                                                                                                                                                                                                                                                                               A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                            READINGS
                                                                                                            2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                                            COMMENCING FABRICATION
                                                                                                            3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                                     RENOVATIONS                                                              [email protected]
                                                                                                                                                                                                                                                              WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                                    DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                                            RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                            4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF         19 PARK CRESCENT, SUNSHINE BEACH                                                                                                            17-Apr-14
                                                                                                            HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                                    Paul Hindes     1077         10:12:17 AM   1 : 100
                                                                                                                                                                                     LOT 0 SP 108797                                                          QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                            5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                              DRAWING No                                 REVISION
                                                                                                            CONSTRUCTION
                                                                                                                                                                                                                                                              23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                            6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                            USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                                     FOR THE BODY CORPORATE OF 19 ON THE PARK   Exclusive Residential and Commercial Designs by Paul Hindes         DA10                                       A

Page 11

                                                                                                                                                                                                    1                                          2




                                                                           PROPOSED ROOF
                                                                           EXTENSION                                                                                                                                                                               AWNING ROOF TO BE
                                                                                                                                                                                                                                                                   REMOVED DOTTED
                                                                                                                                                                                                                                                                     Ceiling
                                                                                                                                                                                                                                                                  RL 37.230
                                                                           PROPOSED BUILDING                                                                                                                                                                       PROPOSED RELOCATED
                                                                           ADDITION
                                                                                                                                                                                                               UNIT 2                                              KITCHEN WINDOWS

                                                                           NEW R.CONC SLAB TO                                       BATH                                     HALL                              LIVING              TERRACE
                                                                           ENG'S DETAILS                                                                                                                                                                            Level 3
                                                                                                                                                                                                                                                                  RL 34.830

                                                                                                                                                                                                                                                                   PROPOSED RELOCATED
                                                                           NEW R.CONC SLAB TO
                                                                           ENG'S DETAILS                                                                                                                       UNIT 1                                              KITCHEN WINDOWS


                                                                                                     WC                             LDY                                                                        LIVING / DINING     TERRACE
                                                                                                                                                                                                                                                                    Level 2
                                                                                                                                                                                                                                                                  RL 31.920



                                                                                                                                                                                                        GARAGE UNIT 2
                                                                                                                                                                     STORE UNIT 1                                                                                   Level 1
                                                                                                                                                                                                                                                                  RL 29.300
                                                                                                                                                                                                                                                                                   DRIVEWAY




                                                                                                                                                                       SECTION A
                                                                                                                                                              A        1 : 100




                                              REV   DATE                  DESCRIPTION           SPECIFICATION NOTES                                                                                                                                                                      DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA                       1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED              PROPOSED DUPLEX                                                             TEL: (07) 5455 3651                   SECTION
                                                                                                                                                                                                                                                                                                                                    A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                                READINGS
                                                                                                2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                                COMMENCING FABRICATION
                                                                                                3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                                       RENOVATIONS                                                                 [email protected]
                                                                                                                                                                                                                                                   WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                         DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                                RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                                4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF       19 PARK CRESCENT, SUNSHINE BEACH                                                                                                               17-Apr-14
                                                                                                HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                         Paul Hindes     1077         10:12:18 AM   1 : 100
                                                                                                                                                                       LOT 0 SP 108797                                                             QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                                5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                               DRAWING No                                 REVISION
                                                                                                CONSTRUCTION
                                                                                                                                                                                                                                                   23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                                6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                                USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                                       FOR THE BODY CORPORATE OF 19 ON THE PARK          Exclusive Residential and Commercial Designs by Paul Hindes     DA11                                       A

Page 12

                                                                                                                                                                           UP


                                                                                                                                                                     ADDITIONAL SITE COVER




                                                                                                                             600
                                                                                                                                                                              0.92




                                          ADDITIONAL SITE COVER
                                                   3.70


                                                                                                                                         EXISTING SITE COVER
                                                                                                                                                199.87


                                          ADDITIONAL SITE COVER
                                                   2.44
                                                                                                                                                                                                                                                   SITE AREA

                                                                                                                                                                                                                            SITE AREA                                                 530.70
                                                                                                                                                                                            600




                                                                                                                                                                     600
                                                                                                                                                                                                                                         PLOT RATIO SCHEDULE
                                                                                                                                                                                                                                                                                       %
                                                                                                                                                                                                                                         Name                      Area sqm           SITE

                                                                                                                                                                                                                           EXISTING GFA UPPER FLOOR                         138.74 26.15%
                                                                                                                                                                                                                           EXISTING GFA MID FLOOR                           132.25 24.93%
                                                                                                                                                                                                                           ADDITIONAL GFA UPPER FLOOR                        32.14  6.06%
                                                                                                                                                                                                                           ADDITIONAL GFA MID FLOOR                          25.28  4.76%
                                                                                                                                                                                                                           TOTAL PLOT RATIO                                 328.41 61.89%
                                          SITE COVER DIAGRAM                                                                                                                                                               ALLOWABLE PLOT RATIO                             318.4     60%
                                   1      1 : 100

                                                                                                                                                                                                                                                   SITE COVER
                                                                                                                                                                                                                                                          Area                 % SITE
                                                                                                                                                                                                                                        Name              sqm                  COVER

                                                                                                                                                                                                                            EXISTING SITE COVER                    199.87             37.67%
                                                                                                                                                                                                                            ADDITIONAL SITE COVER                    7.06              1.33%
                                                                                                                                                                                                                            TOTAL SITE COVER                       206.93             39.00%

                                                                                                                                                                                                                            PERMITTED SITE COVER                    185.7             35%


REV   DATE                  DESCRIPTION              SPECIFICATION NOTES                                                                                                                                                                   DRAWING TITLE

 A    17-4-14 ISSUED FOR DA                          1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED
                                                     READINGS
                                                                                                                          PROPOSED DUPLEX                                                         TEL: (07) 5455 3651                      SITE CALCULATIONS
                                                                                                                                                                                                                                                                                        A3
                                                     2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                     COMMENCING FABRICATION
                                                     3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                          RENOVATIONS                                                             [email protected]
                                                                                                                                                                                                  WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                           DRAWN           PROJECT No   PLOT DATE       SCALE
                                                     RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                     4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                              17-Apr-14
                                                     HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                           Paul Hindes     1077         10:12:22 AM     1 : 100
                                                                                                                          LOT 0 SP 108797                                                         QBSA Lic 1160074 ‐ ABN 81600841459
                                                     5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                            DRAWING No                                   REVISION
                                                     CONSTRUCTION
                                                                                                                                                                                                  23 PALUMA ST SUNRISE BEACH QLD 4567
                                                     6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                     USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                          FOR THE BODY CORPORATE OF 19 ON THE PARK     Exclusive Residential and Commercial Designs by Paul Hindes         DA12                                         A

Page 13

                                                        SE VIEW EXISTING                                                                                                                             SE VIEW PROPOSED
                                                    2                                                                                                                                            1




                                                        NE VIEW EXISTING                                                                                                                             NE VIEW PROPOSED
                                                    3                                                                                                                                            4
                                              REV   DATE                  DESCRIPTION   SPECIFICATION NOTES                                                                                                                                                               DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                        TEL: (07) 5455 3651                   VIEWS
                                                                                                                                                                                                                                                                                                                     A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                        READINGS
                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                        COMMENCING FABRICATION
                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                             RENOVATIONS                                                            [email protected]
                                                                                                                                                                                                                                    WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                          DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                          17-Apr-14
                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                          Paul Hindes     1077         10:12:26 AM
                                                                                                                                                             LOT 0 SP 108797                                                        QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                        DRAWING No                                 REVISION
                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                    23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                             FOR THE BODY CORPORATE OF 19 ON THE PARK     Exclusive Residential and Commercial Designs by Paul Hindes     DA13                                       A

Page 14

                                                               SW VIEW EXISTING                                                                                                           SW VIEW PROPOSED
                                                           1                                                                                                                          2




                                              REV   DATE                  DESCRIPTION   SPECIFICATION NOTES                                                                                                                                                             DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                      TEL: (07) 5455 3651                   VIEWS
                                                                                                                                                                                                                                                                                                                   A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                        READINGS
                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                        COMMENCING FABRICATION
                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                             RENOVATIONS                                                          [email protected]
                                                                                                                                                                                                                                  WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                        DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                        17-Apr-14
                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                        Paul Hindes     1077         10:12:29 AM
                                                                                                                                                             LOT 0 SP 108797                                                      QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                      DRAWING No                                 REVISION
                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                  23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                             FOR THE BODY CORPORATE OF 19 ON THE PARK   Exclusive Residential and Commercial Designs by Paul Hindes     DA14                                       A

Page 15

                                                                                                                                                                                21-23                                                                                   N
                                                                                                                                                                                                                                                                         O
                                                                                                                                                                                                                                                                          RT
                                                                                                                                                                                                                                                                               H




                                                                                                                                                                                                             45° 47' 30"
                                                                                                                                                                                                              33.062 m
                                                                                                                                                                                                        UP




                                                                                                                                303° 4
                                                                                                                                  16.94
                                                                                                                                                                                                19


                                                                                                                                      2' 00"
                                                                                                                                       8m
                                                                                                9




                                                                                                                                                                                                                                     138° 23' 30"
                                                                                                                                                                                                                                                    17.894 m
                                                                                                                                                               UP




                                                                                                                                                                      228° 23' 30"
                                                                                                                                                                        28.730 m




                                                                                                                                                                                       17


                                                                                                11


                                                             SITE CONTEXT PLAN
                                                         1    1 : 200

                                              REV   DATE                  DESCRIPTION   SPECIFICATION NOTES                                                                                                                                                                          DRAWING TITLE

                                               A    17-4-14 ISSUED FOR DA               1. FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TO SCALED            PROPOSED DUPLEX                                                                   TEL: (07) 5455 3651                   SITE CONTEXT PLAN
                                                                                                                                                                                                                                                                                                                                A3
X:\Projects\1077 Malisano\1077 Malisano.rvt




                                                                                        READINGS
                                                                                        2. ALL DIMENSIONS TO BE CHECKED AND VERIFIED ON SITE BEFORE
                                                                                        COMMENCING FABRICATION
                                                                                        3. ALL CONSTRUCTION TO COMPLY WITH THE BUILDING CODE OF AUSTRALIA,
                                                                                                                                                             RENOVATIONS                                                                       [email protected]
                                                                                                                                                                                                                                               WWW.SOULSPACE.COM.AU
                                                                                                                                                                                                                                                                                     DRAWN           PROJECT No   PLOT DATE     SCALE
                                                                                        RELEVANT S.A.A STANDARDS AND LOCAL AUTHORITY REQUIREMENTS
                                                                                        4. WATER CLOSET DOORS OPENING INWARDS TO BE FITTED WITH LIFT OFF     19 PARK CRESCENT, SUNSHINE BEACH                                                                                                                     17-Apr-14
                                                                                        HINGES TO ALLOW THE DOOR TO BE REMOVED WHEN CLOSED.
                                                                                                                                                                                                                                                                                     Paul Hindes     1077         10:12:32 AM   1 : 200
                                                                                                                                                             LOT 0 SP 108797                                                                   QBSA Lic 1160074 ‐ ABN 81600841459
                                                                                        5. REFER ANY ERRORS TO THE DESIGNER BEFORE COMMENCEMENT OF                                                                                                                                   DRAWING No                                 REVISION
                                                                                        CONSTRUCTION
                                                                                                                                                                                                                                               23 PALUMA ST SUNRISE BEACH QLD 4567
                                                                                        6. THIS DRAWING IS COPYRIGHT AND MUST NOT BE RETAINED, COPIED OR
                                                                                        USED WITHOUT THE CONSENT OF THE AUTHOR.
                                                                                                                                                             FOR THE BODY CORPORATE OF 19 ON THE PARK        Exclusive Residential and Commercial Designs by Paul Hindes             DA15                                       A

Used in these records

About this file

File size
2.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

1077 Malisano ISSUED FOR DA 17-4-14.pdf · 2.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.