4.0 Planning assessment

4.1      Key aspects

The Waterways Works Code sets out key criteria for jetties within the Noosa Waters Estate
waterways to comply with. These key criteria are provided below in the following Table


 Criteria                                                  Comment                   Comply

 AO16.1                                                The proposal is setback Y
                                                       from the prolongation of
 For lots with watercourse frontage greater than 15
                                                       the southern boundary
 metres in width, jetties are setback a minimum of 3
                                                       (closest boundary) of 4m
 metres from the prolongation of the boundaries (Refer
                                                       and 6.6m from the northern
 Figure 9.4.9.3A).
                                                       boundary.

 PO18                                                    The handrail is proposed at Y
                                                         a height of 900mm above
 Structures such as handrails, light bollards, piers and
                                                         the jetty floor
 pumping equipment for semi-submersible floating docks
 have a maximum height of 1100mm above the jetty floor.

 AO19.1                                                      The proposal seeks a Y
                                                             maximum jetty width of
 Jetties—
                                                             1.5m and a head of 7m.
     (a) are a maximum width of 1.5 metres;                  The jetty is constructed
     (b) a maximum length of a jetty head is not more than mostly of timber and is less
         7 metres (Refer Figure 9.4.9.3C);                   then    10m   past     the
     (c) constructed predominantly of timber;                quayline.
     (d) are not constructed parallel to the revetment wall;
         and extend a maximum of 10 metres past the
         quayline.


 AO19.2                                                   The jetty head is 10.5m² Y
                                                          and the walkway is greater
 For “Y” and “T” shaped jetty heads or other shaped jetty
                                                          than 3m to the jetty head.
 heads—
      (a) a maximum area of 10.5m² excluding any
          walkway is provided; and
      (b) a walkway with a minimum length of 3 metres is
          provided to the jetty head (Refer Figure
          9.4.9.3D).

 AO19.3                                                  The jetty is proposed Y
                                                         independent     of the
 Jetties have independent support structures and are not
                                                         revetment wall.
 supported by the revetment wall.




                                                                                      Page 6 of 7

Used in these records

About this file

File size
985 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Jetty report - hay feb 2022.pdf · 985 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.