Appendix 6. Odour Buffer Assessment [As Published] · 132007.2399
Report to Pacific Air & Environment Report No. SEPO04176 INTRODUCTION AirLabs was commissioned by Pacific Air and Environment to sample and analyse duplicate odour samples from the following sources at the Noosa Wastewater Treatment Plant: ° Biofilter e Bioreactor e Activated carbon scrubber (attached to the primary clarifiers) All sampling and analysis was conducted by AirLabs on the 30" September 2004. TEST METHODS Odour Odour sampling and analysis was conducted in accordance with the Australian/New Zealand Standard 4323.3 ‘Stationary Source Emissions — Part 3: Determination of Odour Concentration by Dynamic Olfactometry’. Sample Collection Point source samples (carbon scrubber) were collected using the “lung-in-the-box” technique. The sample was drawn through a Teflon® tube that fed into a Nalophan® sample bag. Approximately 40 litres of sample was collected. Area samples (Biofilter and Bioreactor) were collected using an emissions isolation flux hood. All samples were analysed within 30 hours of sample collection. Sample Analysis The odour concentration of each sample was determined using a dynamic olfactometer operating in the forced choice mode utilising a step factor of 1.5. Two ports were available to each panel member; one presenting the odorous gas and one presenting a neutral reference gas. Individual threshold estimates for each panel member were determined and the corresponding odour concentrations were calculated. The odour panellists were all familiar with the procedure and specially selected in accordance with the Australian Standard criteria. The total number of dilutions of the sample at which 50 percent of all responses of the panellists confirmed odour detection is reported as the panel threshold, and is expressed in odour units (OU). The precision of results obtained by these techniques lies statistically within the 95% confidence interval. Odour Emission Rate For those samples collected using the flux hood, the odour emission rate (OER) was calculated by multiplying the odour concentration by a function of the residence time of the odourous air flow and the flux hood’s vertical footprint. airlabs Page 3 of 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix 6. Odour Buffer Assessment [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.8 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.