10 GENERAL NOTES 22 All steel exposed to be hot dipped galvanized with coating mass not less than 6008/sq in
11 The works that are the subject of these plans are structurally adequate for anticipated usage as detailed and 2 3 Stainless steel restraint cables to be min 8mm diem, Grade 316 and in accordance with AS 2837 where
certified on these plans applicable
1.2 All structures depicted have been designed to comply with relevant regulations as set by the local authority,
30 CONCRETE
Queensland Transport and the Prescribed Tidal Work Code (Schedule 4A of the Coastal Protection &
31 All concrete work to comply with AS3600.
Management Regulation 2003)
32 Pontoon concrete strength to be 50t1Pa with 80mm slump U N 0
13 All structures depicted herein have been designed in accordance with Australian Standards AS11701
33 Pile concrete 40 MPa & Abutment Block concrete 32 MPa
(structural design actions) AS1170.2 (wind loads) AS16641(Alum structures) AS17201(timber structures)
34 Minimum cover to the reinforcement - 40mm U N O
AS2159 (piling) AS3600 (concrete structures) AS3962 (design of marinas) A54100 (steel structures) Relevant
local covenants, where applicable, have been considered in the design 40 ALUMINIUM
14 Anchorage piles where applicable have been designed assuming independence from any adjacent revetment 41 All aluminium to comply with AS1664 and to be (minmium) Grade 6063 TS U N 0
structures 4.2. Butt welds, where specified, to have full penetration.
1S Max water level used in the design of any piles shown in the structure is h a t under normal in-service
4 3. Surfaces between aluminium and concrete separated by bituminous membrane
conditions The pies have not been designed for flood conditions in excess of h a t nor scour of the sal around
the base of the piles 50 FLOATATION
16 Where applicable, the existing revetment wall appears Ito the best extent that could be reasonably determined 51 Design stability load applied across half the width of the floating pontoon and on the entire gangway will
via non-destructive Inspection) to be adequate for typical service loads (such as live, dead and impact) that may produce a maximum tilt not exceeding 15 degrees and will not cause any corner to emerge from the water The
he imposed by the proposed gangway/abutment connection minimum freeboard under such loading will not be less than 15mm at any point on the pontoon
17 The following design parameters form the basis for the design of the structure/s depicted herein - 52 Polystyrene SL grade foam to be encased in high density polyethylene membrane fully welded at the corners
17a (Pontoon & Gangway) Single user piled Structure Design Live Load - 2.0 kPa and joins to form a complete seat impervious to marine organisms known to attach to such structures under
17b (Pontoon & Gangway) Multiple user piled Structure Design Live Load (unrestricted access) - 3 0 kPa typical conditions
1.7c (Deck or Jetty) Single user piled Structure Design Live Load - 2 0 kPa
17d (Deck or Jetty) Multiple user piled Structure Design Live Load -10 kPa 60 TIMBER
17e Design Wave height - 0 3 in 61 All timber work to comply with AS 17201 to be minimum Fit hardwood
17f Design ultimate wind velocity - 36 m/s 6.2 All bolted timber connections, where specified, to be galvanized Ior stainless steel equivalent)
17g Max stream velocity (2% exceedance probability) 1.2m/s maximum
17h Anchorage, Mooring, Boardwalk or Jetty (where applicable) to be installed in accordance with AS2159 70 FIXINGS 8, FINISHINGS
to ensure the following minimum Iwoking) design loads are achieved (Unless Noted Otherwise) 71 All fixings to be 316 Grade Stainless Steel UJLO
Bearing Capacity - 4 0 tomes
Gayer{Capadty -V tonnes
IT IS THE OWNERS RESPONSIBILITY TO ENSURE THAT ANY
2 0 STEEL VESSEL BERTHED DOES NOT EXCEED THESE MAXIMUMS
21. All steelwork to comply with AS4100 All welds to be 6mm continuous fillet welds U N 0
DO NOT SCALE DRAWINGS
23503
2990 15000 5514
TOP Of PIM.131%+4.0 Mil , , ......V. EXISTING BUILDING
REUSE EXISTING
/
9 Om x 1320m GANGWAY EXISTING
0350 x 125kN 0350 x 125kN TIMBER DECK
SPUN CONC PILES SPUN CONC MOORING PILE ----t
4 Om MN EMBEDMENT 4 Om MN EMBEDMENT
FFL RL +1.29 AHD I
HAT,RL,+1057AIiD,,,,,,,,V.
__AN W.,S.O ZAP If Iflui j^glglliiiIyIiujIIIIi^IliliiiIIMil$iIIIIIl1lliliIlli
............ Ap4.44g•4 ........V
^. _t1 W5. RL-0 13, _y_. _FT LLLL1Qfr _-^d::dw.'LAA'ri'Fiyn '"'''
L T ."L
I
. LA.T,R4;1123AND,,,,,,,,V.
APPROX SEA
Environmental Protection Agency
R%j VED
ELEVATION Permit No: /Pc^oo ^7iv^
La
SCALE 11100
Li L.;
Nm DATE REWSJON "W err
PROPOSED PONTOON
ATLAS MARINE INTERNATIONAL SUPERIOR' 17/04/08 are mLE ELEVATION & GENERAL NOTES
YRADWAS
SUPERIOR JETTIES jetties cLNMT
MAARRSAm HERITAGE JETTIES
rgYAleIT SIN A1LASMAmeNTWlmilMPTY LTG IBiklliRdAfenue Amidst Old Austrafs 4616-D03 AVAEr55
(LOT 164) 172 GYPS TERRACE
M)PAATG Re[IPIENTMAYKW 0.PTPAWN(1B,simm
NA PEwtlEYANLESYSTEMNAMY PoNLRR TRANMTTWe4
Hail Address PO . Box 920 Neraog 4211 RE375MmNm NOOSAVILLE
ANY NUBS YITWPT Perna wmrnN PmmsseN W Anus fa 1058!]1911
Mime PnmRATINNI PTr, LTG rm 1071M (ETA
beat mroj Wwferjetf esWe D.GO s RS 1A3 1:100
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1173 - Referral Agency Response - EPA [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.