Council archive · source document
07/1173 - Referral Agency Response - EPA [As Published] · 142007.1173
Building Act 1975 sWo & s5 o Building Regulation s46 & s48
Compliance Certificate for building Design or
Specification 15
NOTE A Compliance Certificate states building work complies with the building assessment provisions.
To be used for all classes of building and structures to certify a material, system, method of
building or building element complieswith the RCA or a provision of the QDC.
RESTRICTION: A building certifier (class 0) can only give a compliance certificate aboutwhether
building work complies with the BCA or a provision of the QDC. A building certifier (Class B) can
not give a certificate regarding QDC boundary clearance and site cover provisions.
1. Property description Street address nciude no., street suburb /locality & postcode}
This section need only be completed if 172 Gympie Terrace
details of street address and property
description are applicable Noosaville Postcode 4566
EG. In the case of (atndardfgeneric)
pool designlshell manufacture ndfor
Lot plan details attach bst dnecessary)
patio and carport systems this section .0 164 on CP907410
may not be applicable.
in which focal government area is the land situated?
The description must Idenbry at land be Sunshine Coast Regional Council
srArjed of the appal. atton
The lot 3 plan details (eg SP I RP) are
shown on titledowments ore rates nice.
tf the plan is not registered by title, provide
previous lot and plan details.
2. Description of c omponentls certified
Proposed Jetty Boathouse consisting of timber framed walls and trussed sheet roofs with
Clearly describe Se extent of work covered by
this cergloate timber framed walkway surround.
items not certified: Windows and Doors
Pro-fabricated Roof Trusses, Bracing & Girder Truss Support
Roof sheeting or Tiles
3. Basis of certification Dead and Live Loads and load Combinations
Detail the basis for glhg the cerlifle6M and the
• AS 1170.1
extent lomhich tests, sped dials, rules, • AS 4055 Wind Loads for Houses
standards, codes of practice and other • AS 4100 Steel Structures
pub latlons, were relied upon • AS 1720 Timber Structures
• AS 1684.2 Residential Timber Framed Construction
• AS 2870 Residential Stabs and Footings
• AS 3700 Masonry Structures
• AS 3600 Concrete Structures
AS 2783 Use of Reinforced Concrete for small swimming pools.
Loading Criteria:
Wind Loading: Region: B Terrain Cat: 2.5 Topographic Class: T1
Shielding: PS Design Wind Classification: N3
Floor Loading: Internal: 1.5 kPa Balconies: 3.0 kPa
LOCAL GOVERNMENT USE ONLY ,11011111 r
OMU r•cHwd
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/1173 - Referral Agency Response - EPA [As Published]Related documentApplication case desk ↗
About this file
- File size
- 3.0 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.