Original source · versioned page text
RFI - 20220156 Kauri St OPW REV B
CLASS D (HEAVY DUTY)
TRAFFICABLE GALVANISED
STEEL GRATE AND FRAME
PROVIDE GALVANISED STEP IRONS AT
300mm SPACINGS TO ALL ACCESS POINTS
WHERE DEPTH GREATER THAN 1.2m
INLET PIPE
IL: 111.63 OVERFLOW WEIR
300
RL:11.66
OSD
TWL: 111.56
- 300mm PIPED OUTLET TO
950
DOWNSTREAM DRAINAGE
MIN 1% FALL
IL:110.91
TANK DESIGN TO STRUCTURAL 150mm PVC LOW FLOW PIPE WITH
ENGINEERS SPECIFICATIONS REMOVABLE TRIANGULAR TRASH SCREEN, NON RETURN FLAP VALVE
HOT DIPPED GALVANISED. LYSAGHT
MAXIMESH TYPE RH3030 WITH HANDLE OR
EQUIVALENT 3mm STAINLESS STEEL ORIFICE
PLATE, EPOXY & DYNABOLTED TO
PIT WALL WITH Ø140mm
MACHINED ORIFICE
OSD DETENTION TANK SECTION
C50 SECTION 1:50
HOT DIPPED GALVANISED
LYSAGHT MAXIMESH RH3030
SCREEN WITH HANDLE OR
500mm
APPROVED EQUIVALENT
400mm
BRACKETS FIXED TO PIT WALL TO
HOLD SCREEN IN PLACE TO
MANUFACTURERS SPECIFICATIONS
400mm
TS TRASH SCREEN
C50 DETAIL NOT TO SCALE
CREATE A V-TYPE CHANNEL WITHIN THE BASE OF
EPOXY RESIN ORIFICE PLATE TO MINIMUM Ø10mm x 100mm
TANK GRADING FROM TOP END TO ORIFICE.
WALL AND PROVIDE SILICON DYNABOLTS OR EQUIVALENT
BASE OF TANK TO GRADE TOWARDS V CHANNEL
AROUND EDGES OF PLATE
Ø150mm OUTLET PIPE
13.5m
SHARP EDGED MACHINE CUT
INLET PIPE ORIFICE TO REQUIRED DIAMETER 3mm THICK STAINLESS
IL:111.63m STEEL PLATE
900x900 CLASS D (HEAVY DUTY)
TRAFFICABLE GALVANISED
OP ORIFICE PLATE
MIN
1%
FALL
C50 DETAIL NOT TO SCALE
STEEL GRATE AND FRAME
4.5m
MIN
1%
FALL
FALL
MIN
1%
A A
OUTLET PIPE
IL:110.91m
900x900 CLASS D (HEAVY DUTY) REMOVABLE TRASH SCREEN
TRAFFICABLE GALVANISED
STEEL GRATE AND FRAME
OSD DETENTION TANK PLAN
- PLAN 1:50
CLIENT DETAILS: PROJECT ADDRESS: APPROVED BY: PROJECT NAME:
PROPOSED RESIDENTIAL DEVELOPMENT
SUNSHINE GROVE PTY LTD TITLE: STATUS:
9 KAURI STREET ROADS AND DRAINAGE MATERIAL CHANGE OF USE
© ABN 89 647 469 707
B 28/10/22 RFI ISSUE BRP BRP
COOROY, QLD, 4563 BEN PARRY DETAILS #2 AND
RPEQ: 28084
37 MARY ST
NOOSAVILLE, QLD 4566
A 10/08/22 COMBINED MCU AND OP WORKS ISSUE JAC BRP JB SCALE:
CPEng NER
OPERATIONAL WORKS
+61 7 5211 1003 REV DATE DESCRIPTION DWN CHK APP
AS INDICATED DATE: 28/10/22
DRAWING NUMBER: PROJECT NUMBER: SHEET REV:
SIZE:
RECORCONSULTING.COM REVISIONS
DO NOT SCALE, IF IN DOUBT ASK
C52 20220156 A1 B
See the original