ACOUSTICS & AIR QUALITY
Component
Minimum
of Buildings
Acoustic Rating Acceptable Forms of Construction
External
(Rw)
Envelope
studs; and
(iii) One layer of plasterboard at least 10mm thick fixed to
outside face of studs
OR
Single leaf of brick masonry at least 110mm thick with at
least 13mm thick render on each face
OR
Concrete brickwork at least 110mm thick
OR
In-situ concrete at least 100mm thick
OR
Precast concrete at least 100mm thick and without joints.
Concrete or terracotta tile or metal sheet roof with sarking,
plasterboard ceiling at least 10mm thick fixed to ceiling cavity,
Roof 38
mineral insulation or glass wool insulation at least 50mm
thick with a density of at least 11 kg/m3.
Concrete slab at least 100mm thick
OR
Tongued and grooved boards at least 19mm thick with:
(i) timber joists not less than 175mm x 50mm; and
(ii) mineral insulation or glass wool insulation at least 75mm
thick with a density of at least 11kg/m3 positioned between
joists and laid on plasterboard at least 10mm thick fixed to
Floors 45
underside of joists; and
(iii) mineral insulation or glass wool insulation at least 25mm
thick with a density of at least 11kg/m3 laid over entire floor,
including tops of joists before flooring is laid; and
(iv) secured to battens at least 75mm x 50mm; and
(v) the assembled flooring laid over the joists, but not fixed to
them, with battens lying between the joists.
Fixed so as to overlap the frame or rebate of the frame by not
less than 10mm, fitted with full perimeter acoustically rated
33 seals and constructed of -
Entry doors
(i) solid core, wood, particleboard or blockboard not less than
45mm thick; and/or
(ii) acoustically laminated glass not less than 10.38mm thick.
Noise Category 1
27
(where total
area of glazing Minimum 4mm thick glass with full perimeter acoustically
for a habitable rated seals
room is greater
Glazing than 1.8m2)
24
(where total Minimum 4mm thick glass with standard weather seals
area of glazing
for a habitable
7617R01V02.docx Page 54