Council archive · source document
2ND LODGEMENT REPS engineering · MCU22/0196
THE SITE
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 11 pages
Page 2
DRAWING SIZE — At
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Datum AHD iI
Level Origin PM 105735, RL 4.577
Gympie Tce, Noosaville
Survey information provided by | !
Max Watterson & Associates
LEGEND
+\89 EXISTING SURFACE SPOT LEVELS.
EF INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
—_— w——_ INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
| ——__ INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
— sw/ex ————_ INDICATES STORMWATER DRAIN EXISTING
AS NOTED
www.dialbeforeyoudig.com.au
SAY DIAL 1100
yy BEFORE YOU DIG
“ 42 — ") \W
6 a! P
ye 2 Po mel ane
Top 7.30
Bottom 6.26 |
Window.
Top 7.30
Bottom 6.38}
aneFl9L
|
|
| . |
2 Storey I Window
| Building I
|
I
|
\7,68Eave
Window Opening
N
7.69Eave.
D ,
i 2 Storey
|S Building
eee ee Qe ee A oe —
6 om ny = 3 >
ce 3 5 #12 ¢ gee FH Pf gel |, 98 Bus Shelter |, 9p ele “6
ae ae (i —— SLED “CO Az nb
— . —_+ : aa : 3
‘9 0-95 oS: ee
Az AB iM MBB 09 Loe — wr 120
= ~ 77 AS = == ‘
—_—_ at TT ib 7 POs ASH Los 7AM
aM ast MA 4A yang Moe yee SWPT 441) XA
ee LINEMARKING Bo,
GYMPIE TERRACE
SITE PLAN — SITE SURVEY & EXISTING SERVICES
Scale 1: 200
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
Eaves gS-+t-pos —
7.62Eave Pal ges BSF rie
EXISTING BUILDINGS ig) Gb ot
& Ol w& &
7 eo 8 8
a—"4 10 BE DEMOLISHED 5 °
ave 6.89 al Single Storey
n a
1 3 ao | AB ! ie & = Building
1 ooh 1494 93 ; a“ ,
eA 3 6%
s “0 me 3° oe 2 |
+H Hho? 24 Lanai |
1 Steps | tro! 69 [5 Lor |
Bas Iz i
Se BI 3.75 Hat
L ny yoo! Ile
52 hs He
°
“ esl] si BI
¢ D \ Sl!
1 S I Ss]
[- | g I |
A Q ! It
A\48 | yo 19 SII be |
re | 13 A Pool
' 1S | Ao |
1~ 11 * |
1 B® I i
[AS g | A: 1 i
. 1
is S| Ps | o>
! ~ & i
is 2 6
1° I os 1 12 Ls Ad 1 os
* 48 bey, Ae Ae __#*
}----F--$o——— A ory
1 § Steps | x “46 AS -
i “6 B® an
i_! se
75 we
en | rs rr en
A: A: b
428 WM eo (aah 390 on WM
— pe te
EX. SWPT EXISTING STORMWATER PIT
EX. SMH
EX. SCP
E.0.B.
K&Cc
NS.L.
FH.
TP
EP.
KERB
RCEW
SV
W.M
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL PILLAR
EXISTING KERBING
REINFORCED CONCRETE END WALL
STOP VALVE
WATER METER
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
Revision | Description Date
“FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
SS Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 299
DEBUILD T/A
“SITE SURVEY & EXISTING
SERVICES
130-152 Gympie Tce,
Noosaville
Date: Sept 22 Drawn 1H Design H
| 85, | 32225 -OW11| -
Page 3
DRAWING SIZE — At
KEY CONSTRUCTION NOTES
GENERAL:
EX. SWPT EXISTING STORMWATER PIT 1. DO NOT SCALE FROM THIS DRAWING.
EX. SMH EXISTING SEWER MANHOLE 2. ALL DIMENSIONS IN MILLIMETRES
HEIGHT DATUM EX. SCP EXISTING SEWER CONNECTION POINT 3, SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
E.0.B. EXISTING EDGE OF BITUMEN ARCHITECTURAL DRAWINGS.
LOT 2 & 3 ON MCH3881 K&C EXISTING KERB & CHANNEL 4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
Level Datum AHD II NS.L. NATURAL SURFACE LEVEL ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
Level Origin PM 105735, RL 4.577 F.H. FIRE HYDRANT ENGINEER IMMEDIATELY.
Gympie Tce, Noosaville TP TELSTRA PIT 5, THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
, ; } EP. ELECTRICAL PILLAR SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
Survey information provided by KERB EXISTING KERBING ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
Max Watterson & Associates RCEW REINFORCED CONCRETE END WALL THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
SV STOP VALVE
WM WATER METER
EXISTING SIDE ENTRY
PIT OR SIMILIAR
GRATED PIT
SILT FILTER SOCK TO SURROUND
GRATES AND SIDE ENTRY INTO
Se 40
———— avr 2 6 4, Up
————_ aah at
KERB & CHANNEL +Lp —S—_ \ — CHAPLAIN PARK . /
Aah / ene qh So
SILT FILTER SOCK DETAIL —— / ——— so oot -
‘ + ie
EX. SMH .
EXISTING STORMWATER
PROVIDE SILT FENCE
AROUND INLET AS PER
DETAIL ON THIS SHEET.
PROTECTION OF EXISTING STORMWATER PITS
wa
PROPOSED BASEMENT EXCAVATION
REFER SCG DRG. 32225 — OW3.1
FOR DETAILS
PROVIDE RUMBLE) GRATES
DURING SITE BULK EARTHWORKS.
80-120mm ROCK (NO FINES)
HARD STAND OVERLAY
FOR DELIVERY'S |DURING
CONSTRUCTION. TYPICAL.
—;
% WM #06 ,
— SLI = Shi —
LEGEND. : ws
CREATE BUNDING IN
TEMPORARY HARDSTAND
4\8 EXISTING SURFACE SPOT LEVELS. FOR DIVERISION INTO DUST MOBILISATION FROM WIND ACTION
SILT FENCES. TYPICAL. SITE CONTROL TO INCLUDE PROTECTION AGAINST THE CARRIAGE OF
a SOIL SEDIMENT FROM WIND ACTIONS. SITE FOREMAN TO COVER ALL
* OPP TNS ELECTRICITY BE ener nnn STOCKPILES WITH HESION OR SIMILIAR, PROVIDE SILT FENCING
PROTECT EXISTING AROUND BASE OF STOCKPILES
INDICATES EXISTING SEWER LINE GYMPIE TERRACE LIER SOOk SURROUND.
, MAINTENANCE OF SILT PROTECTION
w—— INDICATES WATER MAIN APPROX REFER DETAIL.
ALIGNMENT, BUILDER TO CONFIRM EXACT SITE FOREMAN TO MAINTAIN ALL SILT AND SEDIMENT PROTECTION Revision | Description Date
LOCATION PRIOR TO WORKS MEASURES THROUGHOUT THE DURATION OF THE PROJECT. ANY SUS.
BREACHING OF THE PROTECTION MEASURES MUST BE REMEDIATED ssue:
a INDICATES TELSTRA LINE APPROX IMMEDIATELY AND REPORTED TO THE ENGINEER FOR CORRECTION FOR APPROVAL
ALIGNMENT, BUILDER TO CONFIRM EXACT MEASURES. SILT RUNOFF PROTECTION IS TO BE MAINTAINED UNTIL
LOCATION PRIOR 10 WORKS SUCH POINT THAT LANDSCAPING IS COMPLETED AND NOT DO NOT SCALE FROM THIS DRAWING
SUSCEPTABLE TO STORMWATER SCOUR. The design and associated details contained on this and associated
drawit ‘ight and t to be id duced without
— sw/ex INDICATES STORMWATER DRAIN EXISTING vgs cr cp adr ot ob wed feed whe
a. Unit 1/11 Project Ave,
——— —TSILF— SILT RETENTION FENCE 10 DETAIL SITE PLAN — SILT & SEDIMENT EROSION PLAN Noosa Heads
Scale 1 : 200 900(W) GEO-FABRIC SILT ~~] SILT RETENTION ¢ Ph (07) 5455 5604
INDICATES POSITION OF RETAINING WALL FENCE, FIXED TO SPIKES ——= THE CONTRACTOR IS TO INSTALL APPROVED SILT 2 \ eal inocp ene oo
RW TO STRUCTURAL ENGINERS DETAIL. AND BURIED 300 INTO s RETENTION FENCES PRIOR TO COMMENCING ANY Z fenuomewnass
STABLE GROUND. © EARTHWORKS, THE FENCE IS TO BE CONSTRUCTED ALONG
STE DRANAGE = CONSTRUCTION THE LOWEST BOUNDARY AND RETURNED UP SIDE Title:
SITE DRAINAGE — CONSTRUCTION BOUNDARIES TO ENSURE FULL STORMWATER ENTRAPMENT.
ONLY CONTRACTOR VO LOCATE alt Senwicre ENSURE GROUND PROFILE DURING CONSTRUCTION SITE_ DRAINAGE — CONSTRUCTION CREACE RUNOFF FROM WITHIN THE ALLLOMMENT Must SILT & SEDIMENT EROSION
PRIOR TO COMMENCING WORKS ON SITE. ALL FALLS TOWARDS THE CENTRE OF THE ALLOTMENT CONSTRUCTED STORM WATER PITS WITHIN THE SITE DRAIN TOWARDS THE FENCE AND SHALL NOT ENTER PLAN
www.dialbeforeyoudig.com.au SERVICES ARE 10 BE PROTECTED IN. THEN TOWARDS THE FRONT BOUNDARY WHERE ARE TO BE COVERED UNTIL THE SITE IS COMPLETED 1200(L) 50 SQ. HOWD NIEGHBOURING ALLOTMENTS THROUGH THE USE OF
ACCORDANCE WITH THE AUTHORITY RUNOFF WILL DRAIN THROUGH THE SILT POND & SILT OR TO BE FITTED WITH SILT PROTECTION MEASURES SPIKES. 1800 GIRS DRIVE SURFACE BUNDING OR SCOUR PROTECTED DRAINS, THE Project
RESPONSIBLE FOR THE SERVICE FENCES. IN NO INSTANCE SHALL THE ALLOTMENT TO THE APPROVAL OF THE ENGINEER 600 INTO GROUND FENCE MUST REMAIN IN PLACE UNTIL SUCH TIME THAT .
DI AL1100 DRAIN INTO NEIGHBOURING ALLOTMENTS. FINISHED LANDSCAPING AND DRAINAGE MEASURES ARE 130-152 Gympie Tce,
BEFORE YOU DIG SILT FENCE DETAIL STALED Noosaville
: D Desi
Date: Sept 29 rawn 1H esign H
0 2 4 6 8 10 Checked: Drg No. Rev.
hunt 1m 1:200 © Al & ppg 5835
1:400 @ A3 | SRchordsn |) | O2220-OW2.1) .
Page 4
DRAWING SIZE — At
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Datum AHD ih
Level Origin PM 105735, RL 4.577
Gympie Tce, Noosaville
Survey information provided by | /
Max Watterson & Associates
SITE_DEWATERING
— THE SITE IS TO BE CONSTANTLY DE-WATERED UNTIL THE GROUND
LEVEL SUSPENDED SLAB IS POURED.
— THE DESIGN AND INSTALLATION OF THE DEWATERING SYSTEM IS TO
BE BY A SPECIALIST CONTRACTOR.
—APPROX GROUND WATER TABLE OF 1.0m BELOW EXISTING GROUND
LEVEL. SEASONAL & TIDAL VARIATIONS NOT CONSIDERED
—GIVEN THE CLOSE PROXIMITY TO THE NOOSA RIVER, GROUNDWATER
LEVELS WILL VARY WITH TIDAL INFLUENCE AND PREVAILING WEATHER
CONDITIONS.
—EXTRACTED GROUNDWATER IS TO BE TREATED IN ACCORDANCE WITH
RECOMMENDATIONS PROVIDED IN A FUTURE DEWATERING MANAGEMENT
PLAN & SITE GEOTECHNICAL REPORT
— TREATED EXTRACTED GROUNDWATER IS TO BE DIRECTED TO COUNCIL
STORMWATER, FINAL OUTLET LOCATION TO BE APPROVED BY NOOSA
COUNCIL.
— PUMPING MUST NOT CAUSE NUISANCE FOR NIEGHBOURS. ENCLOSING
WITHIN A SOUND PROOF ENCLOSURE MUST BE CONSIDERED.
TEMPORARY CFA PILED RETAINING WALLS
— CFA PILED RETAINING WALL DESIGN AND INSTALLATION
BY A SPECIALIST CONTRACTOR
— DRIVING OF PILE WALLS NOT PERMITTED
— INSTALLATION OF GROUND ANCHORS INTO NEIGHBORING
PROPERTIES NOT PERMITTED WITHOUT OWNERS CONSENT
— ADDITIONAL MEASURES SUCH AS GROUTING THE JOINTS
IS RECOMMENDED TO REDUCE GROUNDWATER INFLOWS.
— PROVIDE GROUND MONITORING/VIBRATION CONTROL
DURING INSTALLATION.
— ESTABLISH SURVEY MONITORING POINTS ALONG PILED
WALL TO MONITOR WALL ALIGNMENT/ GROUND MOVEMENT
ESTABLISH SURVEY MOITORING POINTS ALONG PILE WALL
CAPPING BEAM TO MONITOR WALL ALIGNMENT/GROUND
MOVEMENT, PILING CONTRACTORS ENGINEER TO BE ADVISED OF
ANY OBSERVED MOVEMENT
Ground /
pad Teve
UNSTABLE
&
te, 2
THIS FOOTING IS FOUNDED oo
BELOW CRITICAL DEPTH PY, Lid
LINE AND IS STABLE. STABLE ye oN
PIERS OR UNDERPINNING FOUNDED
BELOW THE CRITICAL DEPTH LINE
WOULD BE NEEDED TO SUPPORT
ANY FOOTING THAT IS FOUNDED
ABOVE THE CRITICAL DEPTH LINE. 30 De
Horizontal
CRITICAL DEPTH LINE
LEGEND
48.077
+180
EXISTING STRUCTURE /DWELLING
INCLUDING NEIGHBOURING
ALLOTMENTS
THE BUILDER /CONTRACTOR
SHALL CONFIRM ALL
RELEVANT LEVELS PRIOR 10
COMMENCING WORKS.
I
t
| THIS FOOTING WITHOUT
t_ PIERS |S FOUNDED
ABOVE CRITICAL DEPTH
LINE AND IS UNSTABLE.
|
I
{
\ UNE OF PROPOSED
\—"— EXCAVATION OR OTHER
| TRENCH.
|
I
|
ees
NOTE:
THIS DETAIL ALSO APPLIES TO EXISTING
FOUNDATIONS ON NEIGHBOURING
PROPERTIES. SHEET PILING MUST BE
INSTALLED WHERE EXISTING FOOTINGS WILL
BE FOUNDED ABOVE ANY EXCAVATION
CRITICAL DEPTH LINE
--~~ INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES DEPTH OF CUT (NEGATIVE) OR
/D
FILL (POSITIVE) AS NOTED
INDICATES AREA OF CUT
INDICATES AREA OF FILL
INDICATES POSITION OF TEMPORARY
RETENTION SHORING, DESIGN AND
INSTALLATION BY SPECIALIST CONTRACTOR
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
w——_ INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
a INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAI
AS NOTED
IN EXISTING
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINERS D
www.dialbeforeyoudig.com.au
BEFORE YOU DIG
ETAIL.
BUILDER TO MAINTAIN STABILITY
OF ALL NEIGHBOURING STRUCTURES,
REFER CRITICAL DEPTH LINE DETAIL
ON THIS SHEET
bot BASEMENT WALLS TO STRUCTURAL FINAL BASEMENT SLAB THICKNESS TO
Zz | ENGINEERS DETAIL BE DETAILED BY STRUCTURAL KE
wo | ENGINEER
ce |
a ! PAVEMENT AS EX. SMH
s|= ? RAFT SLAB 10 DETAILED ON DRG a
I STRUCTURAL ows. K&C
1} ENGINEERS DETAIL. NSL.
! 5 FH.
wD Ee FPL AS & EP.
“ez FPL AS NOMINATED. S KERB
| “ NOMINATED. S RCEW
ees SSeS = Se Se ee See ee i SV
LL) 7 we TF o wa 7 we we 77 y, L/y WM
VLIS LLL AL AK IL LD AL ILIDL AL CLI ALLEL CSL LLL PL LL
eR Ne TANKING WATERPROOF BLANKET WITH
PRIMER & PROTECTIVE COATING INSTALLED
BY SPECIALIST CONTRACTOR TO DRIVEWAY / CARPARK PAVEMENT
MANUFACTURERS’ SPECIFICATIONS &
CERTIFICATION.
FINISHED LEVELS DIAGRAM
FINISHED LEVELS DIAGRAM TYPICAL SECTION
TYPICAL SECTION
——— “Up
———. 7
tL —_——__ -
° => __ CHAPLAIN: PARK ;
AS / N Aah 4
” ri 3p + é
TOP :
BTM :
ENSURE 600mm MIN. BEHIND
PILING TO ALLOW FOR
ACCESS FOR BASEMENT
WALL WATERPROOFING.
TYPICAL.
TOP
BIM
TOP
BTM :
TOP
BIM
EX. SWPT EXISTING STORMWATER PIT
EX. SMH
4.
Se A
RESIDENTIAL
a DASHED LINE INDICATE:
X° PROPOSED BUILDING
FOOTPRINT
PILES TO BE BACKFILLED
~~ 7
|
| FOLLOWING BASEMENT K\ 1
| CONSTRUCTION. i Gy
| /
a “Gas
2) | RIVEWAY (og) Pe
* REFER Drg. OW4.1 & epost hy
. j OW4.2 FOR DETAILS. 4 Hom
I
|
—
TOP : 2.10
[BTM : 1.45
H = 0.65m
INDICATES TEMPORARY CFA CONCRETE PILING OR SIMILAR,
DESIGN AND INSTALLATION BY OTHERS. MINIMUM VIBRATION
TECHNIQUES TO BE USED FOR INSTALLATION, VIBRATION
t——— CONTROL AND MANAGEMENT BY PILING CONTRACTOR. BUILDER
TO CONFIRM EXTENT REQUIRED TO SATISFY CRITICAL DEPTH
LINE PROTECTION OF NEIGHBOURING STRUCTURES.
REFER DETAIL.
TOP : 2.50
BIM : 1.50
H = 1.00m
DEVELOPMENT {Bt
Lo ‘ JI LIN ESTABLISH SURVEY MOITORING POINTS ALONG PILE WALL
mo | -40 CAPPING BEAM TO MONITOR WALL ALIGNMENT/GROUND
a FFL: —0.300 ane A LM MOVEMENT, PILING CONTRACTORS ENGINEER 16 BE ADVISED OF
FPL: —0.700 f ANY OBSERVED MOVEMENT
ms | a
I SN i
IN : TOP : 210
x o | » | BTM : 1.55
! ‘ys - | Q 4 H = 0.55m
| 5 N &
LL
TOP : 2.30
| BTM : 1.50
/H= 0.80m
DASHED LINE INDICATES APPROX. ON SITE
STOCKPILE & TREATMENT AREA FOR ACID
| SULPHATE SOILS (ASS). ENSURE SURFACE
GRADES PROMOTE FALL INTO BASEMENT
TERRACE
SITE PLAN — EARTHWORKS & PILING PLAN
Scale 1: 200
PRIOR TO COMMENCING WORKS,
UNDERTAKE DILAPIDATION REPORTS OF
ALL NEIGHBORING DWELLINGS/STRUCTURE
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
S PRIOR TO COMMENCING WORKS ON SITE. ALL
CONTRACTOR TO REPAIR ADJACENT THE
CONSTRUCTION SITE KERB, FOOTPATH OR
ROAD RESERVE IF ANY DAMAGE IS SUSTAINED
DURING CONSTRUCTION. GRASSED AREAS ARE
TO BE RE TOP SOILED AND TURFED.
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
SITE GEOTECHNICAL
INFORMATION/ RECOMMENDATIONS PRESENTED IN
PACIFIC GEOTECH REPORT ON GEOTECHNICAL
INVESTIGATION (PROJECT PG-9236) DATED NOV
2022,
NOTE:
CUT/FILL LEVELS SHOWN REPRESENT THE FINISHED PAD
LEVEL (FPL) TO THE UNDERSIDE OF THE GROUND BEARING
SLABS AND PAVEMENTS AND INCLUDES THE CRUSHER
DUST OR ROAD BASE LAYERS 10 BE PROVIDED UNDER THE
SLABS. ADDITIONAL LANDSCAPING FILL NOT INCLUDED.
DILAPIDATION REPORT:
PRIOR TO ANY CONSTRUCTION
UNDERTAKE DILAPIDATION REPORT OF ALL
NEIGHBORING DWELLINGS/ STRUCTURES.
EXCAVATIONS, TYPICAL. FINAL LOCATION
TO BE DETERMINED BY PRINCIPLE
CONTRACTOR.
RC PILES, DESIGN
BY OTHERS
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL PILLAR
EXISTING KERBING
REINFORCED CONCRETE END WALL
STOP VALVE
WATER METER
EXISTING GROUND LEVEL
—_ vv
@nen
EXCAVATION DEPTH
V
SITE PREPARATION, EARTHWORKS & COMPACTION
SITE PREPARATION, EARTHWORKS, TEMPORARY BATTERS
& COMPACTION TO BE IN ACCORDANCE WITH THE
SPECIFICATIONS AND REQUIREMENTS OF OF PACIFIC
PILE DESIGN BY OTHERS
(OCD CONCRETE PILED RETAINING WALL
GEOTECH REPORT ON GEOTECHNICAL INVESTIGATION
(PROJECT PG-9236) DATED NOVEMBER 2022,
(7 SECTION
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
FILLING NOTES
—THE SITE IS TO BE SCRAPED CLEAR OF ALL ORGANIC
MATERIAL AND DEBRIS.
—THE SUBGRADE IS TO BE ROLLED WITH A VIBRATING STEEL
DRUM ROLLER TO ACHIEVE A MINIMUM RELATIVE FIELD
DENSITY OF 98%. THE COMPACTION IS TO BE SUFFICIENT TO
ACHIEVE A BLOW COUNT OF 7 BLOWS PER 300mm WITH AN
APPROVED PERTH SAND PENETROMETER FOR A DEPTH OF
1.0m BELOW EXCAVATED LEVEL. COPIES OF COMPACTION TEST
RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
—UNLESS NOTED OTHERWISE A MINIMUM BEARING CAPACITY
OF 100kPa SHOULD BE ACHIEVED WITHIN COMPACTED FILLING.
COMPACTION & BEARING CAPACITY TEST RESULTS MUST BE
PRESENTED TO SCG CONSULTING ENGINEERS FOR APPROVAL
PRIOR TO WORKS PROCEEDING.
—THE FILL MATERIAL CLEAN GRANULAR MATERIAL (I.E. SAND
TO A CLAYEY SAND IN ACCORDANCE WITH AS1726) BE FREE
OF ANY ORGANIC MATERIAL AND HAVE A CLAY CONTENT OF
LESS THAN 12% (PLASTICITY INDEX LESS THAN 25%, LINEAR
SHRINKAGE OF 15%). THE PROPOSED MATERIAL IS TO BE
INSPECTED BY SCG CONSULTING ENGINEERS PRIOR TO ITS
REMOVAL TO ENSURE ITS COMPATIBILITY.
—THE FILL IS TO BE PLACED AND COMPACTED IN
ACCORDANCE WITH AS3798-1996 TO A LEVEL SUFFICIENT TO
ACHIEVE A LEVEL 2 CERTIFICATION WITH A MINIMUM RELATIVE
FIELD DENSITY OF 98%. COPIES OF COMPACTION TEST
RESULTS SHALL BE PRESENTED TO SCG CONSULTING
ENGINEERS FOR APPROVAL.
FILLING AND COMPACTING ADJACENT EXISTING STRUCTURES
IS TO BE IN STRICT ACCORDANCE WITH THE ASSOCIATED
DETAILS AND SPECIFICATIONS.
—AREAS WHERE EXISTING STRUCTURES OR TREES ARE
REMOVED SHALL BE BACKFILLED WITH THE APPROVED FILL
MATERIAL COMPACTED IN ACCORDANCE WITH AS2870-1996 TO
ACHIEVE A MINIMUM RELATIVE FIELD DENSITY OF 987.
—ANY LOOSE OR SOFT MATERIAL UNCOVERED IN THE SITE
PREPARATION SHALL BE REMOVED AND REPLACED WITH THE
APPROVED FILL MATERIAL COMPACTED IN ACCORDANCE WITH
AS2870-1996 TO ACHIEVE A MINIMUM RELATIVE FIELD
DENSITY OF 98%.
—SITE DRAINAGE AND SILT PROTECTION MEASURES MUST BE
ISTALLED PRIOR TO CONSTRUCTION COMMENCING.
B COUNCIL RFI 06.09.23
A COUNCIL RFI 27.02.23
Revision | Description Date
Iss
* FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
C) S06
DEBUILD T/A
Title:
EARTHWORKS PLAN
Project
150-132 Gympie Tce,
Noosaville
Date: Sept WD) Drawn Design 1H
Checked: Drg No. Re
15400 @ AS | Fearn |) [O2229 —OW3.1) B
Page 5
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
Page 6
DRAWING SIZE — At
Level Datum AHD
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Origin PM 105735, RL 4.577 I
Gympie Tce, Noosaville
Survey information provided by | !
Max Watterson & Associates
48.077
+180
5.0% >
Fal
RAMP. ww
x | 29.740
(SWP)
GD-xxx
RAMP. wx.
— sw/ex
wee RV
LEGEND
INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES FINISHED SURFACE GRADE
INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES PROPOSED FINISHED
SURFACE LEVELS
FIELD INLETS OR JUNCTION BOX PRE-CAST
CONCRETE CAST-INTO PAVEMENT. REFER DRG
SW1.1 FOR FURTHER DETAILS.
GRATED DRAIN CAST-INTO PAVEMENT.
REFER DRG SW1.1 FOR FURTHER DETAILS
SLAB POUR BREAK CONTROL JOINT,
REFER DRG. OW4.3 FOR DETAILS
DENOTES WET TOOLED JOINT TO TERRACE
SLAB, REFER TO DRG. OW4.3 DETAILS
DRIVEWAY SLAB/PAVEMENT. REFER TO
NOTES AND DETAILS ON DRG. OW4.3 FOR
THICKNESS AND REINFORCING.
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
TERRACE SLAB. REFER TO STRUCTURAL
DETAILS FOR THICKNESS AND
REINFORCING.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINEERS DETAIL.
www.dialbeforeyoudig.com.au
SA DIAL 1100
yy BEFORE YOU DIG
SAWCUT EXISTING FOOTPATH AND |SMOOTH
TRANSITION TO NEW FOOTPATH,
EXTEND NEW FOOTPATH CONCRETE 100mm
UNDER CUT EDGE OF EXISTING FODTPATH.
TYPICAL
DEMOLISH & REMOVE EXISTING
~~ ~_CHAPLAIN PARK
To
ee
ee -
EX. SMH Vent Ping
Oo
o lo - |
o q | POOL C] POOL |
o Oo Ft
| 4 a a = :
E 4 o a oO
7 o (sup) 5 = (SwP) (SW) = qo
St _| iG o
|
4 (ot) L_
<= I (SWP) (SWP)
\ os] mA \ | 9 |
= \ \ |
oe
GROUND GROUND GROUND
FFL 2.700 FFL 2.700 FFL 2.700
1 \ ) |
gt - LE PSA —
—_— 1 |
oo Or] nla |
| GHP) \ RESIDENTIAL ! RESIDENTIAL | (SWP)
= | Y00 | DEVELOPMENT.) | 8) vo | DEVELOPMENT | op |\ *
— ——+ (swe) | (SWP) — —
FOR STORMWATER PIT
DETAILS. REFER DRG. =) —— — —N — —\
32225-SW1.1. TYPICAL — —|—
oo f 'O |
oO 7 _
o 1 <i ‘ o
Jo | : \
5 GARAGE baRAGE <4
o | GARAGE GARAGE
o FFL 2.200 SN \ FFL 2.200 \ FFL 2.200 FFL 2.200
o g = . | PROPOSED UNDERGROUND
Ja 3 | TRAFFICABLE WATER TANKS, REFER
& 4 s610n_. ~ 5.670m 610m 610m a DRG. 32225-SW1.1 FOR DETAILS
Mt
a aa —_ qT 2.400m | (7. = iS ] — aE
# |i |) WATER | Po, warer| | | Pwater | | _ ob pwater ;
ae TANK | jp gf TAN bast. @) TANK | |S LT TANK boom he
3 6 3 \ S Ze ' S |
ND STEP, _e ee ices BE sea \ S [ts IS
| PRP EO ~ pen
3 1 Sy |. iis ‘ (Td) ON
¢ | sf --a}= SS S L Zo NI
ee ee [ Ra Bt Tp eH Upq
(swe) ai} CD=XKK S UL Fifer arcmin (SWP)
aaaiiaad 6.0 = WM 4 W.M
& , ——~ —- -
|
eS x Faaooccaaaee NEW 1.8m WIDE FOOTPATH Cop P=
Sa
ee f SLI aa a =
———— foe a
aM
NEW K & C «| LINE MARKING
qWPh nnn EES) -- = 5
7.0m_AT FLARES Av
DRIVEWAY CROSSOVER AND
RE-CONSTRUCT NEW TYPE B1 BARRIER
KERB & CHANNEL AS PER NOOSA
COUNCIL STD DETAIL IPWEA RS—080.
MAINTAIN EXISTING SURFACE GRADES
AND ENSURE SMOOTH TRANSITIONS.
DRIVEWAY CROSSOVER (SHOWN HATCHED) 10
BE GENERALLY IN ACCORDANCE WITH IPWEA
STD DRG RS-051 (GENERAL WIDE) AND
COUNCIL REQUIREMENTS. LEVELS AS NOTED.
GYMPIE TERRACE
NEW CONCRETE FOOTPATH/PAVED
AREAS SHOWN SHADED TO COUNCIL
|___ STANDARDS (IPWEA Drg SEQ R-065),
MAX TOOL JOINT SPACINGS AT 2.0m
CTRS, REFER LANDSCAPE ARCHITECTS
PLAN FOR SURFACE TREATMENTS
DRIVEWAY CROSSOVER AND
MATCH EXISTING.
SITE PLAN — DRIVEWAY & CROSSOVER PLAN
Scale 1
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
: 200
MAXIMUM CROSS-FALL OF 1 in 40 ON ALL
FOOT-PATHS AND INTERNAL PEDESTRIAN
PATHS AND RAMPS
ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1 COUNCIL STANDARD DETAILS
RE-CONSTRUCT NEW TYPE B1 BARRIER
KERB & CHANNEL AS PER NOOSA
COUNCIL STD DETAIL IPWEA RS-080.
MAINTAIN EXISTING SURFACE GRADES
AND ENSURE SMOOTH TRANSITIONS.
ROAD ASPHALT EDGE TO BE SAW CUT
AS REQUIRED AND REINSTATED TO
NEW KERB & CHANNEL TO BE IN ACCORDANCE
WITH IPWEA STANDARD Drg. SEQ-RS—-080 &
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
CONTRACTOR TO TOPSOIL AND TURF ANY
DISTURBED OR DAMAGED AREAS OF THE ROAD
RESERVE ADJACENT THE CONSTRUCTION SITE
CONTRACTOR TO REPAIR ADJACENT THE
CONSTRUCTION SITE KERB, FOOTPATH OR
ROAD RESERVE IF ANY DAMAGE IS SUSTAINED
DURING CONSTRUCTION. GRASSED AREAS ARE
CONTRACTOR TO REPAIR/REINSTATE ANY
DAMAGED AREAS OF EXISTING FOOTPATHS,
KERB & CHANNELS TO COUNCIL STANDARDS
TO BE RE TOP SOILED AND TURFED.
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SMH — EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
SV STOP VALVE
W.M WATER METER
Hated in accordance with the landscape plan
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING,
2, ALL DIMENSIONS IN. MILLIMETRES
3, SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE 10 BE REFERRED 10 THE
ENGINEER IMMEDIATELY.
5, THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE. WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2, MINIMUM. CONCRETE THICKNESSES:
PAVEMENT (VEHICLES): 125mm U.N.O.
FOOTPATHS: 100mm _U.N.O.
3. CONCRETE IN ACCORDANCE WITH AS360 AND AS1379
AND MINIMUM STRENGTHS AS FOLLOWS:
PAVEMENT (VEHICLES): 32 MPa
FOOTPATHS: 25 MPa
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. REINFORCEMENT FABRIC TO AS 1504, PLACED CENTRAL
SLAB DEPTH.
6. MAX. 1 in 40 CROSSFALL (ACCROSS) ON FOOTPATHS.
7. EXPANSION JOINTS AS NOTED (T.J.) ON PLANS TO BE
10mm WIDE WET TOOLED WITH EVERY 2ND MESH WIRE CUT
ALONG JOINT. REFER DETAIL.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO
INSIDE EDGE OF CURVE
10. ALL EXISTING SERVICES TO BE LOCATED AND PROTECTED
AS REQUIRED PRIOR TO WORK COMMENCING
B COUNCIL RFI
06.09.23
A COUNCIL RFI
27.02.23
Revision | Description
Date
“FOR APPROVAL
drawings are copyright and are not to be used or reproduced
the written permission of SCG Consulting Engineers.
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
without
DEBUILD T/A
ABN 40 098 481 899
Unit 1/11 Project Ave,
F Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
Title:
DRIVEWAY & ACCESS PLAN
10 . Checked: Drg No.
ru. -—1 1:200 @ Al 3
400 @ AS : 8 Richordson 32225-OW4.1
Project
130-152 Gympie Tce,
Noosaville
Date: Sept 22 Drawn 1H Design H
B.
Page 7
DRAWING SIZE — At
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Datum AHD
Level Origin PM 105735, RL 4.577 I
Gympie Tce, Noosaville Ny
Survey information provided by | /
Max Watterson & Associates
LEGEND
_--777 INDICATES PROPOSED SURFACE
RAMP. ~x.
—— SW/EX
oe RW
CONTOURS AND LEVELS TO AHD.
EXISTING SURFACE SPOT LEVELS.
INDICATES FINISHED SURFACE GRADE
INDICATES DIRECTION OF FALL
TO FINISHED SPOON DRAINS.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES PROPOSED FINISHED
SURFACE LEVELS
FIELD INLETS OR JUNCTION BOX PRE-CAST
CONCRETE CAST-INTO PAVEMENT. REFER DRG.
SW1.1 FOR FURTHER DETAILS.
GRATED DRAIN CAST-INTO PAVEMENT.
REFER DRG. SW1.1 FOR FURTHER
DETAILS
DENOTES WET TOOLED JOINT TO TERRACE
SLAB, REFER TO DRG. OW4.3 DETAILS
DRIVEWAY SLAB/PAVEMENT. REFER TO
NOTES AND DETAILS ON DRG. OW4.3 FOR
THICKNESS AND REINFORCING.
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
TERRACE SLAB. REFER TO STRUCTURAL
DETAILS FOR THICKNESS AND
REINFORCING.
INDICATES DIRECTION OF RAMP UP OR
DOWN AS INDICATED
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINEERS DETAIL.
www.dialbeforeyoudig.com.au
SS DIAL 1100
BEFORE YOU DIG
~~ ~_CHAPLAIN PARK
Vent Pive
oOooooo0o0000
¢ (SWP)
. \ oy nN \ |
x \ |
ak d |
GROUND ROUND = GROUND GROUND
FFL 2.700 FFL 2.700 FFL 2.700 FFL 2.700
fof \ ) |
=
3 LI + OF ERAAAN Ss \ Sh
re | ! |
by peeps |
GHP) RESIDENTIAL Vi RESIDENTIAL | S
4" || Y00 | DEVELOPMENT.) YS ele tl oy | DEVELOPMENT.) op
— —F (swe) | (SWP) — —
FOR STORMWATER PIT \) ,
DETAILS. REFER DRG =» —— = S
32225-SW1.1. TYPICAL s— -==> ess
oo f
1 | I |
oO 4
Oo 7 I Ls 2
30 | | ; \
qo GARAGE | GARAGE p= 1
a | | GARAGE GARAGE
O L220 TOS 220° — Lb — 6 -2.299- —— 11 — — FF 2200 4
QO CE L \ | PROPOSED UNDERGROUND
£5 (way) | TRAFFICABLE WATER TANKS, REFER
# 5 \ 5 DRG. 32225-SW1.1 FOR DETAILS
Le ___| P in \ NJ
|\Yo4ag] nen ap bah oe AK 19750
1 | . [2A 5 Sr | TE
q a NU a i NS S . q
NEW FOOTPATH TO MAINTAIN i oe ot TBP 5 &
TEN ORNEWAY toc NON }---p 7 6SB fe a We a nea =
1 — : 1 rt Zs |
STEP. : me 1018] | J 1:807] 2,075 200K rea] _ [1.999 i] 3
SWP a WM # WM
<8 * TP
E E
pes
DRIVEWAY CROSSOVER (SHOWN HATCHED) TO
BE GENERALLY IN ACCORDANCE WITH IPWEA
STD DRG RS-051 (GENERAL WIDE) AND
COUNCIL REQUIREMENTS. LEVELS AS NOTED.
LK ob LINE MARKING
a
GYMPIE TERRACE
NEW CONCRETE FOOTPATH/PAVED
AREAS SHOWN SHADED TO COUNCIL
|___ STANDARDS (IPWEA Drg SEQ R-065),
MAX TOOL JOINT SPACINGS AT 2.0m
CTRS, REFER LANDSCAPE ARCHITECTS
PLAN FOR SURFACE TREATMENTS
DRIVEWAY CROSSOVER AND
RE-CONSTRUCT NEW TYPE B1 BARRIER
KERB & CHANNEL AS PER NOOSA
COUNCIL STD DETAIL IPWEA RS-080.
MAINTAIN EXISTING SURFACE GRADES
AND ENSURE SMOOTH TRANSITIONS.
ROAD ASPHALT EDGE TO BE SAW CUT
AS REQUIRED AND REINSTATED TO
MATCH EXISTING.
SITE PLAN — DRIVEWAY LEVELS & LINE MARKING
Scale 1: 200
CONTRACTOR TO LOCATE ALL SERVICES PRIOR 10
COMMENCING WORKS ON SITE. ALL SERVICES ARE
TO BE PROTECTED IN ACCORDANCE WITH THE
AUTHORITY RESPONSIBLE FOR THE SERVICE
ALL LINE MARKING TO BE IN ACCORDANCE MAXIMUM CROSS-FALL OF 1 in 40 ON ALL
WITH THE QUEENSLAND MANUAL OF UNIFORM FOOT—PATHS AND INTERNAL PEDESTRIAN
TRAFFIC CONTROL DEVICES & A.S 2890.1 PATHS AND RAMPS
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
CONTRACTOR TO TOPSOIL AND TURF ANY
DISTURBED OR DAMAGED AREAS OF THE ROAD
RESERVE ADJACENT THE CONSTRUCTION SITE
CONTRACTOR TO REPAIR/REINSTATE ANY
NEW KERB & CHANNEL TO BE IN ACCORDANCE
DAMAGED AREAS OF EXISTING FOOTPATHS,
KERB & CHANNELS TO COUNCIL STANDARDS
WITH NOOSA SHIRE COUNCIL STANDARD Drg.
RS-080 & COUNCIL STANDARD DETAILS
KE
EX. SWPT
EX. SMH
EX. SCP
E.0.B.
K&Cc
NS.L.
FH.
TP
EP.
KERB
RCEW
SV
W.M
EXISTING STORMWATER PIT
EXISTING SEWER MANHOLE
EXISTING SEWER CONNECTION POINT
EXISTING EDGE OF BITUMEN
EXISTING KERB & CHANNEL
NATURAL SURFACE LEVEL
FIRE HYDRANT
TELSTRA PIT
ELECTRICAL PILLAR
EXISTING KERBING
REINFORCED CONCRETE END WALL
STOP VALVE
WATER METER
10 . Checked: Drg No. Rev
1:200 @ Al sg
me 15200 @ AS | SRthorson | | O2225-OW4.2 B.
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE TO BE REFERRED TO THE
ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2. MINIMUM CONCRETE THICKNESSES:
PAVEMENT (VEHICLES): 125mm U.N.O.
FOOTPATHS: 100mm_U.N.O.
3. CONCRETE IN ACCORDANCE WITH AS360 AND AS1379
AND MINIMUM STRENGTHS AS FOLLOWS:
PAVEMENT (VEHICLES): 32 MPa
FOOTPATHS: 25 MPa
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. REINFORCEMENT FABRIC 10 AS 1304, PLACED CENTRAL
SLAB DEPTH.
6. MAX. 1 in 40 CROSSFALL (ACCROSS) ON FOOTPATHS.
7. EXPANSION JOINTS AS NOTED (T.J.) ON PLANS 10 BE
10mm WIDE WET TOOLED WITH EVERY 2ND MESH WIRE CUT
ALONG JOINT. REFER DETAIL.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO
INSIDE EDGE OF CURVE
10. ALL EXISTING SERVICES TO BE LOCATED AND PROTECTED
AS REQUIRED PRIOR TO WORK COMMENCING
B COUNCIL RFI 06.09.23
A COUNCIL RFI 27.02.23
Revision | Description Date
Iss
* FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 299
>» Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
Title:
DRIVEWAY LEVELS
Project
130-152 Gympie Tce,
Noosaville
Date: Sept 22 Drawn 1H Design H
Page 8
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
Page 9
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
Page 10
DRAWING SIZE — At
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Datum AHD
Level Origin PM 105735, RL 4.577 I
Gympie Tce, Noosaville
Survey information provided by | !
Max Watterson & Associates
LEGEND
_---77 INDICATES PROPOSED SURFACE
18.07 CONTOURS AND LEVELS TO AHD.
4189 EXISTING SURFACE SPOT LEVELS.
5.0% 5 INDICATES FINISHED SURFACE GRADE
(SWP) FIELD INLETS OR JUNCTION BOX PRE-CAST
FBR) _ CONCRETE CAST-INTO PAVEMENT. REFER ORG
SW1.1 FOR FURTHER DETAILS.
GD=xxx GRATED DRAIN CAST-INTO PAVEMENT.
(Cry )«~—CREFER ORG SWI.1 FOR FURTHER DETAILS
DRIVEWAY SLAB/PAVEMENT. REFER TO
NOTES AND DETAILS ON DRG. OW4.3 FOR
THICKNESS AND REINFORCING.
L_]
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
L_]
TERRACE SLAB. REFER TO STRUCTURAL
DETAILS FOR THICKNESS AND
REINFORCING.
— E —— INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES EXISTING SEWER LINE
— w—— INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
| ——__. INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
—— Sw/ex INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES POSITION OF RETAINING WALL
TO STRUCTURAL ENGINEERS DETAIL.
wee RV
www.dialbeforeyoudig.com.au
SA DIAL 1100
yy BEFORE YOU DIG
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SMH — EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K&C EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
FH. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
SV STOP VALVE
W.M WATER METER
\ \
O \ N
C]
) \ \
! L | \ \ \
| R555) ee SE | 1
| | rs [os me
i | pos ———_ | 7
| \. NS Zi
IL Ne po SHE \
| fe Lf | - |
\. \
| eo Te \
|_---- ~==—____ DRIVEWAY \. \ |
—— ~ REFER Drg. OWT & 9 | Qn
OW4.2 FOR DETAILS. \. “eo |
| WN ‘ \. a
\ \. _ years IN UO
l oP 3 Se N _ eee Tt
U- iain SS | ————
le N a eee eee eee
ail |
Loh WM + | WM
@: 4S _ __ __ NY
—____@)—_—
FH q.P \+
E E newia — a -
~~ fd 9M WIDE FOOTPATH [W________._. Tl i
[|_J 7 \e) AD es W/EX SH
xe 7 =I a7 q Po ------___ AN AD - - aAy
TY Sam TOT ‘ oe {Nh RT TTA
, R12-14A(L) Al ' N
Ae ‘
PROPOSED DRIVEWAY (ACCESS)
LOCATION INDICATED BY 4 | LINE MARKING a
HATCHING, REFER DRG. OW4.1 & ONLY qo. ---- ae
OW4.2 FOR DETAILS a A: qi
LEFT TURN ONLY ON A.
LEFT SIDE OF DRIVEWAY.
FACING NORTH
GYMP
If TERRACE
R2-6A(R)
OPPOSITE SIDE OF ROAD
FOR EXITING VEHICLES
FACING NORTH.
NO
RIGHT
TURN
NO RIGHT TURN ON a
SITE PLAN — PROPOSED SIGNAGE PLAN
Scale 1: 100
ALL SERVICES SHOWN ON THIS PLAN INDICATIVE
ONLY CONTRACTOR TO LOCATE ALL SERVICES
PRIOR TO COMMENCING WORKS ON SITE. ALL
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
ALL LINE MARKING TO BE IN ACCORDANCE
WITH THE QUEENSLAND MANUAL OF UNIFORM
TRAFFIC CONTROL DEVICES & A.S 2890.1
PARKING FACILITIES PART 1: OFF-STREET CAR
PARKING
RESPONSIBLE FOR THE SERVICE
Checked:
Munmni———1_P——{__?m1:100 @ At S| peg 5835
1:200 @ A3 “|S Richardson
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING,
2, ALL DIMENSIONS IN. MILLIMETRES
3, SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM THE
ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND THE
ARCHITECTURAL DRAWINGS ARE 10 BE REFERRED 10 THE
ENGINEER IMMEDIATELY.
5, THE BUILDER IS RESPONSIBLE FOR LOCATING ALL EXISTING
SERVICES WITHIN AND ADJACENT THE ALLOTMENT AND SHALL
ENSURE THAT ALL NEW WORKS ARE IN ACCORDANCE. WITH
THE ATTACHED CRITICAL DEPTH LINE DIAGRAM.
FOOTPATHS AND DRIVEWAYS:
1. EXISTING FOOTPATHS TO BE SAW CUT PRIOR TO REMOVAL
2, MINIMUM. CONCRETE THICKNESSES:
PAVEMENT (VEHICLES): 125mm U.N.O.
FOOTPATHS: 100mm U.N.O.
3. CONCRETE IN ACCORDANCE WITH AS360 AND AS1379
AND MINIMUM STRENGTHS AS FOLLOWS:
PAVEMENT (VEHICLES): 32 MPa
FOOTPATHS: 25 MPa
4. CONCRETE SURFACE TOLERANCE +5.0mm OVER 3.0m
5. REINFORCEMENT FABRIC TO AS 1504, PLACED CENTRAL
SLAB DEPTH.
6. MAX. 1 in 40 CROSSFALL (ACCROSS) ON FOOTPATHS.
7. EXPANSION JOINTS AS NOTED (T.J.) ON PLANS TO BE
10mm WIDE WET TOOLED WITH EVERY 2ND MESH WIRE CUT
ALONG JOINT. REFER DETAIL.
8. ONE ACCESS POINT PERMITTED FOR EACH ALLOTMENT.
9. FOR CURVED DRIVEWAYS, MAXIMUM GRADES APPLY TO
INSIDE EDGE OF CURVE
10. ALL EXISTING SERVICES TO BE LOCATED AND PROTECTED
AS REQUIRED PRIOR TO WORK COMMENCING
Revision | Description Date
Iss
* FOR APPROVAL
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
drawings are copyright and are not to be used or reproduced without
the written permission of SCG Consulting Engineers.
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 299
C) St
DEBUILD T/A
Title:
SIGNAGE PLAN
Project
130-152 Gympie Tce,
Noosaville
Date: Sept 22 Drawn 1H Design H
Drg No. Rev.
52225-OW6.1,
Page 11
DRAWING SIZE — At
Level Datum AHD
HEIGHT DATUM
LOT 2 & 3 ON MCH3881
Level Origin PM 105735, RL 4.577 H
Gympie Tce, Noosaville
Survey information provided by | !
Max Watterson & Associates
+180
F,
Ellin
S.L. 12.50
LLL. 12.00
L
L_]
[x] cr2
Ej cP3
(RCS)
Fe
GD-150
—— SWw/EX
Sw
oe RW
48077
LEGEND
EXISTING SURFACE SPOT LEVELS.
INDICATES PROPOSED SURFACE
CONTOURS AND LEVELS TO AHD.
INDICATES DIRECTION OF FALL
TO FINISHED GROUND SURFACE.
INDICATES SURFACE LEVEL (S.L.) AND INVERT
LEVEL (|.L.) OF ADJACENT STORMWATER PIT
DRIVEWAY SLAB/PAVEMENT. REFER TO NOTES
AND DETAILS ON DRG. OW4.1 FOR THICKNESS
AND REINFORCING.
LANDSCAPING, REFER LANDSCAPE
ARCHITECT FOR DETAILS.
600Sq IPWEA TYPE 2A FIELD INLETS,
PRE-CAST CONCRETE WITH HEAVY DUTY
GRATE WHERE INSTALLED IN PAVED
AREAS.
450Sq STORMWATER JUNCTION BOX,
PRE-CAST CONCRETE. AND SEALED
LID. REFER TP DETAIL ON DRG. SW1.2
400Sq GRATED FIELD INLETS, POLY AND LIGHT
DUTY GRATE WHER IN LANDSCAPE AREAS.
ROOF WATER CONNECTION, REFER
HYDRAULIC CONSULANT FOR
INTERNAL DRAINAGE DETAILS,
TYPICAL.
150(W) GRATED DRAIN WITH HEAVY
DUTY GRATE.
INDICATES OVERHEAD ELECTRICITY
SUPPLY LINE
INDICATES WATER MAIN APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES TELSTRA LINE APPROX
ALIGNMENT, BUILDER TO CONFIRM EXACT
LOCATION PRIOR TO WORKS
INDICATES STORMWATER DRAIN EXISTING
AS NOTED
INDICATES STORMWATER DRAIN PROPOSED
AS NOTED MIN 1 IN 100 FALL UNLESS
NOTED OTHERWISE
INDICATES POSITION OF CONCRETE
SLEEPER RETAINING WALL TO
STRUCTURAL ENGINERS DETAIL.
www.dialbeforeyoudig.com.au
SAY DIAL 1100
‘Wy BEFORE YOU DIG
| FALL LANDSCAPED AREAS 10
| FORMED FLOW PATHS 10 DIVERT
| RUNOFF TO GRATED INLETS 1 in
100 MIN FALL. ALLOW FOR
OVERFLOW TO COUNCIL PARK AT
REAR. TYPICAL
| PROPOSED UNDERGROUND TRAFFICABLE
| WATER TANKS (LU3000 LATTICE
| UNDERGROUND TANK) FOR STOMRWATER
RE-USE FOR NON-POTABLE PURPOSES.
ROOF STORMWATER ONLY MIN CAPACITY
3000 It PER DWELLING.
|
REFER TO HYDRAULICS
CONSULTANT FOR INTERNAL
DRAINAGE.
/ FOR REINFORCING.
7 } oe a,
DRAINAGE PIPE SIZES ——
AS NOTED.
APPROVED COMPACTED
BEDDING SAND.
EX. 3750 RCP
US IL: 0.00 (APPROX.)
DS I.L: UNKNOWN
(ASSET ID 1034208)
ROOF DRAINAGE:
ALL GUTTERS AND DOWNPIPES TO
——_ +r
ae
+ SS
— CHAPLAIN PARK
HH
EX. SMH
S| |o (p=s=———lo deel
o ——==$__||__-------—__ _
o | Ss
olo SSS
a Oyo} | || Poo C POOL yf
Oo oy = LH 0
pasancng GPS CP3 009 | OT st 2.360 | E) >t eee Oo,
oO [sb 2350|[SL BN C |G LLL 1.900 GP3 ¢p3 of
© LL. 1.900 ff LL. 1.900 | % lo ‘4 Oo
x Ss te Fy ; 4. an
GP3 LAs 4 4 46S; 2 g 4 4 %% 4
=a a a
FALL|LANDSCAPED AREAS 10 i — T - _ - \ © = = CP3
FORMED FLOW PATHS TO DIVERT iL. 1. \ |
RUNOFF TO GRATED INLETS 1 in rl GPS GP3 YN SL 2.100
100 WIN FALL. ALLOW FOR Nd SL. 2.200 S.L._ 2.200 LL 1.700
OVERFLOW TO COUNCIL PARK AT a] ‘ ILL. 1.800 ILL. 1.800 g
REAR] TYPICAL GROUND ROUND \] ain GROUND GROUND
” FFL 2.700 FFL 2.700. FFL 2.700 FFL 2.700
Jz/[ AAS AAAN8S se. Yo \ Veg
ds fs j s/|-Hts — S Jfs
6B — IL 8 2 iB
Wy Py ain = ARF A
| GP3 ES/IDENTIA GP3 GP3 ¢
Scan) 4,” vow Na 5 SD ba ESIDENTIA . GPs
IL 1.500 EVEL OPMENT. SL. 2.350 SL 2.350 vol
— iL. 1.500 iL. 1.500 — — SL 2.200
a LL. 1.400
# N : La
go g |F- ws ‘
=] 4
H 4 z S
J a] ° ; \ s
Poh Hatt =
‘Eb GARAGE / SARAGE | GARAGE GARAGE 3
Sip FFL 2.200 \ . = FFL 2.200 FFL 2.200 I
3H = ww LS
— \ oO oO |
3 =) > > =
é © \ _.|5 SB. \
| Sis ili iis
_ t«édéaSF' d b
= | WATER [~-==--—, .
an
|S __-
BUILDER TO POT HOLE LOCATE AND | ae \Y SL 685
CONFIRM EXISTING SERVICES LOCATIONS cp. EEE ito
& LEVELS BEFORE ANY EARTHWORKS a as oe 2258 uPVC
ARE CARRIED OUT. REPORT ANY Po cael (on EY wNat SL. 1.920
DISCREPANCIES TO THIS FIRM. <8 'R f 1508 uPVC as IL. 0.750 °
i - *% EH s1
—~ ~NEW 1.8m WIDE FOOTPATH =| 388
I" mn
2/125x75x4.0 RHS (GALV.) ae ] RCS Pl a ae ae ap =
LAID AT 1 in 100 MIN. INSTALL TO Sa SO A a ore ——— “EY SwpT at
NEW KERB ADAPTORS IN ~ mI " wt
ACCORDANCE WITH COUNCIL STD = re LINEMARKING =f |
DETAIL RS-081 & MAKE | AS EX. STORMWATER PIT
FOOTPATH GOOD. TYPICAL. SL: 1.05
GYMPIE TERRACE | Buitoer To conriRM EXISTING ILL: 0.00 (APPROX.)
STORMWATER PIT LEVELS PRIOR 10 (ASSET ID 1003814)
COMMENCING WORKS, REPORT ANY
DISCREPANCIES TO THIS FIRM
DRIVEWAY PAVEMENT. REFER
DRIVEWAY & ACCESS PLAN
SITE PLAN — SITE STORMWATER MANAGEMENT
Scale 1: 200
we 300mm MIN THK COMPACTED ALL SERVICES SHOWN ON THIS PLAN INDICATIVE ALL STORMWATER FINISHED SITE DRAINAGE. IN
GRANULAR MATERIAL UNDER SLAB. ONLY CONTRACTOR TO LOCATE ALL SERVICES ACCORDANCE WITH HYDRAULICS
TRAFFICABLE AREAS PRIOR TO COMMENCING WORKS ON SITE. ALL PIPES TO BE LAID AT CONSULTANTS DOCUMENTATION.
©@— MIN 98% FIELD DENSITY THROUGH
BACKFILL DEPTH. D>900mm
NON-TRAFFICALBE AREAS
COMPACT IN 150mm LAYERS D>400mm
/- \SW PIPE TRENCH/PIPE BEDDING & BACKFILLING
\{_/ UNDER PAVEMENT TYPICAL SECTION
SERVICES ARE TO BE PROTECTED IN
ACCORDANCE WITH THE AUTHORITY
RESPONSIBLE FOR THE SERVICE
1:100 MIN. UNO.
COMPLY WITH BCA VOLUME 2 PART
3.5.3
KE
EX. SWPT EXISTING STORMWATER PIT
EX. SMH — EXISTING SEWER MANHOLE
EX. SCP EXISTING SEWER CONNECTION POINT
E.0.B. EXISTING EDGE OF BITUMEN
K&Cc EXISTING KERB & CHANNEL
NS.L. NATURAL SURFACE LEVEL
F.H. FIRE HYDRANT
TP TELSTRA PIT
EP. ELECTRICAL PILLAR
KERB EXISTING KERBING
RCEW REINFORCED CONCRETE END WALL
S.V STOP VALVE
W.M WATER METER
RAINFALL
LANDSCAPING ROOF RUNOFF
ee
TO GROUNDWATER
WATER CYCLE DIAGRAMATIC
cS
WATER
TANKS
cs
ON-SITE STORMWATER
PITS, GRATED DRAINS
& JUNCTION BOXES.
RUNOFF TO COUNCIL
INFRASTRUCTURE
Checked:
hunnt———L__p——1__1m1:200 @ Al st ppg 5835
1:400 @ A3 “|S Richardson
CONSTRUCTION NOTES
GENERAL:
1. DO NOT SCALE FROM THIS DRAWING.
2. ALL DIMENSIONS IN MILLIMETRES
3. SETTING OUT DIMENSIONS ARE TO BE OBTAINED FROM
THE ARCHITECTURAL DRAWINGS.
4. ANY DISCREPANCIES BETWEEN THESE DRAWING AND
THE ARCHITECTURAL DRAWINGS ARE TO BE REFERRED
TO THE ENGINEER IMMEDIATELY.
5. THE BUILDER IS RESPONSIBLE FOR LOCATING ALL
EXISTING SERVICES WITHIN AND ADJACENT THE
ALLOTMENT AND SHALL ENSURE THAT ALL NEW WORKS
ARE IN ACCORDANCE WITH THE ATTACHED CRITICAL
DEPTH LINE DIAGRAM.
HYDRAULICS
1. HYDRAULIC SERVICES SHOWN ARE DIAGRAMATIC ONLY.
REFER TO ARCHITECTURAL DRAWINGS FOR LOCATIONS OF
FIXTURES.
2. ALL SANITARY HYDRAULICS AND WATER RETICULATION
WITHIN THE ALLOTMENT BOUNDARY TO BE IN
ACCORDANCE WITH AS3500.
3. ALL WORK SHALL COMPLY WITH THE REQUIREMENTS
OF AUTHORITIES HAVING JURISDICTION, AFTER OBTAINING
ALL NECESSARY PERMITS AND APPROVALS.
4. THE CONTRACTOR IS TO CONFIRM THE POSITION OF
ALL EXISTING SERVICES AS INDICATED ON THESE AND
ASSOCIATED PLANS PRIOR TO THE COMMENCING OF
WORK.
5. STORMWATER DRAINAGE PIPES SHALL BE CLASS SH
UPVC OR RUBBER RING JOINTED REINFORCED CONCRETE
PIPE LAID AT A MINIMUM GRADE OF 1 IN 100 U.N.O.
JOINS ARE TO BE CONSTRUCTED IN ACCORDANCE WITH
THE MANUFACTURERS REQUIREMENTS.
6. SEWERS 100mm DIAM. UPVC U.N.O. AND LAID AT A
MINIMUM GRADE OF 1 IN 60.
7. WATER SUPPLY PIPEWORK BELOW GROUND IS TO BE ;
63MM DIAM. OR LESS — HIGH DENSITY TYPE 50
CLASS 12 POLYETHYLENE
8. ALL ABOVE GROUND AND INTERNAL WATER SUPPLY
PIPEWORK TO BE TYPE B COPPER.
9. WATER SERVICES ARE NOT PERMITTED IN GROUND
SLABS AND ALL JOINS AND CONNECTIONS SHALL BE
MADE ABOVE THE SLAB.
10. FIRE HYDRANTS ARE TO BE INSTALLED ARE TO BE
INSTALLED IN ACCORDANCE WITH AS2419.1. HOSE REELS
ARE TO BE INSTALLED IN ACCORDANCE WITH AS2441.
11. CLEAN-OUTS, INSPECTION OPENINGS AND CLOSING
CAPS SITUATED IN VEHICULAR OR PEDESTRIAN
PAVEMENTS ARE TO BE FITTED WITH EITHER BRASS OR
CAST-IRON COVERS.
12. ALL IN-GROUND VALVES SHALL BE IN ACCORDANCE
IN APPROVED CONCRETE PATH BOXES.
13. ALL WASTE PIPES AND WATER SERVICES
PENETRATING SLABS TO BE WRAPPED IN AN APPROVED
FLEXIBLE JOINT JOINT WRAPPING.
14. THE TERM ’SERVICE’ REFERS TO THE MINIMUM
INTERNAL PIPE DIAMETER UNLESS NOTED OTHERWISE.
DRIVEWAY
B COUNCIL RFI
06.09.23
A WATER RE-USE TANKS ADDED
27.02.23
Revision | Description
Date
“FOR APPROVAL
drawings are copyright and are not to be used or reproduced
the written permission of SCG Consulting Engineers.
DO NOT SCALE FROM THIS DRAWING
The design and associated details contained on this and associated
without
C) St
ABN 40 098 481 899
DEBUILD T/A
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
email:[email protected]
web:www.scg-engineers.com
Title:
PLAN
STORMWATER MANAGEMENT
Project
130-152 Gympie Tce,
Noosaville
Drawn
Sept 22 TH I Design
Date:
Drg No.
52225-SW1.1
TH
B.
Page 12
Issue:
Unit 1/11 Project Ave,
Noosa Heads
Ph (07) 5455 5604
DEBUILD T/A
email:[email protected]
web:www.scg-engineers.com
ABN 40 098 481 899
Title:
Project
Date: Drawn Design
Checked: Drg No. Rev.
Rev. - 10.06.16
Used in these records