Intrax
HOUSING
MINIMUM REQUIREMENTS FOR
SEWER ARTICULATION
sire SEWER EXIT POINTS & ORG
Chass | DESIGN Ys MOVEMENT (mm)
SWIVEL EXPANDER
M Ys<40 0 0
H1 40<Ys < 60 1 1
H2 60<Ys 75 2 1
E Ys >75 2 1
NOTE:
EXPANDER REQUIRED ON ALL RISERS FOR (CLASS E, Ys >75mm
OR EQUIVALENT SITES
“EXPANDA” JOINT (LUBRICATED
WRAPPED IN 2 LAYERS OF 200
MICRON POLYTHENE & SEALED
WITH PRESSURE SENSITIVE TAPE
TO EXCLUDE SOIL PARTICLES).
(REFER TO SCHEDULE)
SEWER MAIN OR
BRANCH LINE
MIN 15 DEGREE BEND TYPICAL
“EXPANDA” JOINT (LUBRICATED
WRAPPED IN 2 LAYERS OF 200
MICRON POLYTHENE & SEALED
WITH PRESSURE SENSITIVE TAPE
TO EXCLUDE SOIL PARTICLES).
(REFER TO SCHEDULE)
NOTE:
REFER WAFFLE SLAB SCHEDULE
FOR REINFORCEMENT DETAILS
REMOVE PART OF VOID
FORM AS REQUIRED.
VERTICAL EXPANSION
JOINT REQUIRED FOR ‘E’
SITE ONLY.
DRAINAGE PIPE
SELECTED ARTICULATION JOINT, EG.
STORM PLASTICS “SWIVEL JOINT”
OR OTHER APPROVED FLEXIBLE
FITTING, TO BE INSTALL AS PER
MANUF'S SPECIFICATIONS, TYP.
(REFER TO SCHEDULE)
TYPICAL UNDER WAFFLE
SLAB PIPE DETAIL
SCALE = 1:20
NOTE:
REFER WAFFLE SLAB SCHEDULE
FOR REINFORCEMENT DETAILS
(44)| - — — — FJ
4 VOID FORM
LAGGING THICKNESS:-
25mm FOR H1 SITES& 40mm ON
—— “E" OR EQUIVALENT SITES
UNLESS NOTED OTHERWISE
SELECTED ARTICULATION JOINT, EG. STORM
PLASTICS “SWIVEL JOINT” OR OTHER APPROVED
FLEXIBLE FITTING INSTALLED TO MANUFACTURES
RECOMMENDATIONS. (REFER TO SCHEDULE)
TYPICAL PIPE THROUGH
FOOTING DETAIL - SECTION
SCALE = 1:20