33020-0-03 D Pump Station Site Plan 2 August 2008
33020-0-04 C Sea Water Supply Pump Station G.A. 3 August 2008
33020-0-05 B Sea Water System Site Plan 3 March 2008
33020-8-01 E Transfer Pipeline Alignment 2 August 2008
and as may be amended by these conditions.
2. Suitable signage shall be placed at the perimeter of the work areas advising that the area is not
accessible for members of the public. The signs shall be placed prior to construction works commencing
and permanently affixed to the inlet jetty and pump station upon completion of the works. The design of
the signs shall be approved by Council’s Manager – Works Planning prior to the erection of the signs.
3. Existing trees on the site and within road reserves are to be retained, except where required to be
removed due to building operations or the conduct of the approved use.
4. The clearing or disturbance of existing vegetation shall be limited to the proposed works area and any
necessary access ways extending from the existing road formation to the works area.
5. Any areas of removed or disturbed vegetation remaining after the works shall be replaced with suitable
local native vegetation approved by Council. The revegetation shall be carried out in accordance with
Council’s Planning Scheme Policy No 3 Landscaping Plants & Guidelines.
6. Any person acting on this permit shall prevent erosion and sediment export from leaving the site. Site
control measures such as silt fencing, controlled gravel access to the site and controlled disposal of
waste, will be necessary.
7. Certification by a Registered Professional Engineer of Queensland shall be submitted to Council stating
that the works have been constructed in accordance with best practice methods, is in accordance with
Coastal Protection and Management Act 1995 (specifically the engineering previsions of the Coastal
Protection and Other Legislation Amendment Regulation (No.1) 2005, Schedule 4A – IDAS Code for
development applications for prescribed tidal work) and is structurally sound.
8. This approval or its conditions do not constitute a ruling on structural safety and the applicant must make
their own arrangements to ensure adequacy of design and work. Furthermore, the approval does not
warrant that associated plans and specifications have been checked in detail, nor does it absolve the
owner of the land from complying with all the conditions of this approval and/or relevant Council By-Laws
and Policies and/or relevant statutes and/or statutory regulations in the execution and/or performance of
the works. The Council does not accept any responsibility for the accuracy of any plans and
specifications as approved.
9. The Development Permit for a Operational Works lapses if the use has not happened by 9 January
2011, unless an application to extend the currency is approved by Council.
5 REFERRAL AGENCY CONDITIONS
The referral agencies applicable to this application are:
Referral Trigger Referral Status Referral Agency Referral Address
Tidal work that is Concurrence Environmental Ecoaccess Customer Service
prescribed tidal work other Protection Agency Unit,
than in a canal PO Box 15155, CITY EAST
QLD 4002
Tidal work that is Concurrence Queensland Transport MacArthur Avenue East
prescribed tidal work – Maritime Services PINKENBA Qld 4008
Qld
A copy of any referral agency conditions is attached.
Page 2 of 7
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
SUPERSEDED - 08-383 - Decision Notice [As Published]Related documentApplication case desk ↗
About this file
- File size
- 56 KB (small file)
- File type
No other editions are linked here.