Council archive · source document
Apdx 3 - Civil Eng Plans · MCU24/0001
Plans and drawings: the text below has words only, no drawings.
DOWEL BAR SCHEDULE U.N.O
SLAB DIA. MIN LENGTH MAX SPACING
THICKNESS (mm) (mm) (mm) (mm)
125 16 350 300
150 20 400 300
150-200 24 450 300 1.2 LONG N12 TRIMMER BARS TO
TABLE IN ACCORDANCE WITH AS3727 END OF DISCONTINUED JOINTS
NOTE: WHERE CONTRACTION JOINTS ARE SKEW TO THE JOINTS AS SPECIFIED
CONCRETE DETAILS MAIN JOINTING LAYOUT. ENSURE THAT DOWELS ARE
RESIDENTIAL INTERNAL ALIGNED PARALLEL WITH THE MAIN JOINTING LAYOUT.
SERVICE OR
DRIVEWAY RESIDENTIAL DRAINAGE PIT (IJ)
CROSSOVER DRIVEWAY FOOTING, WALL OR OTHER FORM
125mm 125mm OF BLOCKOUT STRUCTURE (IJ)
DEPTH (D)
LJ
CONC. STRENGTH (f'c) 32 MPa 25 MPa
REINF. MESH SL72 SL72
CJ
TABLE IN ACCORDANCE WITH COUNCIL REQUIREMENTS AND AS3727
1.2 LONG N12 TRIMMER
BARS TO ALL CORNERS
MESH COVER CJ
LJ
LJ
TOP 50mm
SIDES 50mm
75mm (FORMED JOINT) CJ
SIDE (CONTROL JOINT)
LJ
75mm (WEAKENED PLANE JOINT) 1.2m LONG N12 TRIMMER
BARS TO ALL CORNERS
TYPICAL TRIMMER BAR ARRANGEMENT
DOWEL ORIENTATIONS AT INTERNAL CORNERS
MESH AND COVER SCALE N.T.S
AS SPECIFIED SCALE N.T.S
CONCRETE AS SPECIFIED
'D'
50mm SAND LAYER, OR 100mm BASE TYPE 2.5 (98% MMDD)
(IF REQUIRED) OVER COMPACTED SUBGRADE (95% MDD)
200um MOISTURE BARRIER IF EARTHWORKS TO REFER "FORMED
SUBGRADE (#) JOINT" DETAIL FOOTING, WALL OR OTHER FORM 75mm TYPICAL
ORDERED, LAPPED 200mm
MESH AND COVER OF BLOCKOUT STRUCTURE MESH AND COVER PROPRIETARY PERMANENT
AS SPECIFIED AS SPECIFIED CAPPING STRIP(#)
TYPICAL CONCRETE PAVEMENT CONCRETE
PAVEMENT
CONCRETE PAVEMENT
SCALE N.T.S AS SPECIFIED
AS SPECIFIED
SUBBASE OR BEDDING 4-N16 x 600mm LONG PLAIN HOT SUBBASE OR BEDDING
NOTE: LAYER AS SPECIFIED DIP GALVANISED DOWELS AT LAYER AS SPECIFIED
· CONCRETE JOINTS IN ACCORDANCE WITH IPWEA RS-065 FOR PATHS 1200mm CENTRES. INSTALL AT
· SLAB CONSTRUCTION AND JOINTING TO BE IN ACCORDANCE WITH THE 'GUIDE TO RESIDENTIAL DRIVEWAYS & DOORWAYS ONLY 200um MOISTURE BARRIER IF DOWELLED OR PROPRIETARY
200um MOISTURE BARRIER IF IF DIRECTED JOINT SYSTEM
STREETS & PATHS' - CEMENT AND CONCRETE ASSOCIATION OF AUSTRALIA FOR DRIVEWAYS ORDERED, LAPPED 200mm
ORDERED, LAPPED 200mm
# OPTION FOR TEMPORARY CAPPING STRIP,
REMOVED AND APPROVED SEALANT APPLIED
ISOLATION JOINT ABUTTING STRUCTURE (IJ) EXPANSION JOINT (KJ) WITH KEY
SCALE N.T.S SCALE N.T.S
(MAX JOINT SPACING; 12m)
REFER "SAW CUT JOINT" DETAIL REFER "FORMED
JOINT" DETAIL
75mm TYPICAL
MESH AND COVER MESH AND COVER 75mm TYPICAL EXPANSION CAP
AS SPECIFIED AS SPECIFIED 25mm GAP
CONCRETE PAVEMENT CONCRETE PAVEMENT
AS SPECIFIED SECOND POUR FIRST POUR AS SPECIFIED
SUBBASE OR BEDDING SUBBASE OR BEDDING
LAYER AS SPECIFIED LAYER AS SPECIFIED
ROTATE BAR FOLLOWING FIRST POUR, PLAIN GALVANISED DOWELS,
200um MOISTURE BARRIER IF REMOVE, LUBRICATE AND REINSERT TO
CUT EVERY SECOND WIRE AND FREE FROM BURS. BOND BREAKING
ORDERED, LAPPED 200mm PROVIDE 10mm END VOID
DEPRESS MESH TO MAINTAIN COVER COMPOUND OR DOWEL SLEEVE
INDUCED CRACK
SAWN CONTRACTION JOINT (CJ) EXPANSION JOINT (EJ), DOWEL BAR
Filename: C:\ARCOSGROUP\2023 PROJECTS - DOCUMENTS\230703 - URB RES - 2 JAN STREET, NOOSA HEADS\3.0 CAD\DRAWINGS\OPW\230703-OPW-C-372.DWG
SCALE N.T.S SCALE N.T.S
(MAX JOINT SPACING; PATHS 2m NOM OR PATH WIDTH,
SLABS 3m OR 1.5 TIMES WIDTH OF SLAB PANEL)
SEALANT SHALL BE ELASTOMERIC FUEL
RESISTANT POLYSULPHIDE NONPORITE 10mm WIDENING SAW CUT 1/3 0.25Dx6 WIDE. 6mm SCW
8mmØ POLYETHYLENE TUBE BACKING ROD
6mm
THIOXOL SL OR APPROVED EQUIVALENT
AND SEALANT REQUIRED IN SANDY AREAS
0.25D
16mmØ POLYETHYLENE
Last saved by: HARRYDAVIES(2023-12-18) Last Plotted: 2023-12-18
TUBE BACKING ROD
16mm SCW
10mm
30mm
10mm "ABELFLEX" WITH
3mm SAW CUT
RIP OFF STRIP
FORMED JOINT SAW CUT JOINT
SCALE N.T.S SCALE N.T.S
North Point Scale Horiz. Datum Client Consultant Project Drawing
LOCAL Drawn HD Project No. Drawing No. Rev No.
GREG & KERI VENTER DUAL OCCUPANCY CONCRETE JOINTING
0m 0.125 0.25 Design HD
(IZAROX PTY LTD) OPERATIONAL WORKS - CIVIL DETAILS
A1 1:5
0m 0.25 0.5
Vert. Datum
AHD
2 JAN STREET Check GM
230703 OPW-C-372 A
RL Datum CIVIL | STRUCTURAL | GEOTECHNICAL
NOOSA HEADS, QLD, 4567 Approved Approved Date Signed Sheet
A FOR APPROVAL
Rev Revision Description
18.12.23 LS
Date Approved
A1 1:10 COPYRIGHT © All rights reserved.
This work is copyright and cannot be reproduced
or copied in any form without the prior consent
SUNSHINE COAST | BRISBANE | GOLD COAST
www.arcosgroup.com.au | ABN 51 640 311 842
LACHLAN SWANN
RPEQ 21223
18.12.23 Status FOR APPROVAL
Size A1
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Apdx 3 - Civil Eng Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.