following—
i) a distributed live load of
5.0kPa;
ii) a concentrated live load
of 4.5kN;
iii) the load of the largest
vehicle capable of being
on the boardwalk or
deck;
(b) subject to paragraph (c), a
boardwalk or independent deck
not accessible to vehicular traffic
is able to support at least the
following—
i) a distributed live load of
5.0kPa;
ii) a concentrated live load
of 4.5kN;
(c) if a relevant planning scheme
standard is more stringent than
the standard mentioned in
paragraph (a) or (b)—the
relevant planning scheme
standard, to the extent it is
more stringent than the
standard mentioned in
paragraph (a) or (b).
15.3 Prescribed tidal work that is a The design and construction of the Complies – The proposed deck does
boardwalk or an independent deck does boardwalk or deck is consistent with the not unreasonably restrict remedial works
not prevent or hinder remedial work following standards— to the banks of the Noosa River.
being undertaken on any bank of tidal
water or for any existing retaining wall, (a) subject to paragraph (b), a
revetment or seawall or another existing boardwalk or independent deck
structure. either—
i) can be easily dismantled
and reassembled; or
ii) does not restrict the
movement of machinery
ordinarily used for
remedial work to any
bank of tidal water or
any existing retaining
wall, revetment or
seawall or other existing
structure;
(b) if a relevant planning scheme
standard is more stringent than
the standard mentioned in
paragraph (a)—the relevant
planning scheme standard, to
the extent it is more stringent
than the standard mentioned in
paragraph (a).
Design, construction and safety—jetties and piers
Not Applicable - works not for a jetty or pier
Design, construction and safety—pipelines and other underground services
Not Applicable - works not for a pipeline or other underground service
Design, construction and safety—pontoons
Not Applicable - works not for a Pontoon
Design, construction and safety—retaining walls, revetments and seawalls
Not applicable – works not for retaining walls, revetments or seawalls
Design, construction and safety—wharves
Not applicable – works not for a wharf
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Assessment Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 1.6 MB (small file)
- File type
No other editions are linked here.