Development on the former bowls generally in accordance with
club site located at Lot 3 RP884396 Figure 7.2.5.4 (Noosa Junction
includes a road connection through Framework and Character Plan)
the site linking Noosa Drive to
Lanyana Way which is to be
constructed and dedicated to
Council at no cost as part of the
first stage of development of the
site.
Height                                AO16.1                              Not applicable
PO16                                  Buildings and other structures      The proposal is      within   an
Buildings and other structures:       have a building height of no        existing building.
                                      more than:
   1. are low rise and have a
      visual bulk and architectural      1. Noosa Junction - 12
      scale consistent with                 metres;
      structures on adjoining or         2. Noosa Business Centre –
      nearby land;                           1. if a site is identified
   2. have the following                        as a gateway site on
      maximum building height:                  Figure 7.2.4.5 (Noosa
       1. for Noosa Junction                    Business Centre
          three storeys;                        Framework and
                                                Character Plan), that
       2. for the Noosa Business
                                                portion of the site
          Centre two storeys,
                                                located within 50
          except a gateway site or
                                                metres of the street
          a mixed-use building
                                                frontage - 12 metres;
          incorporating a
                                                or
          residential use which
          may be three storeys.              2. are part of a
                                                mixed-use building
   3. do not visually dominate the
                                                incorporating
      street, surrounding spaces
                                                residential uses, or in
      or the existing skyline; and
                                                the High density
   4. preserve the amenity of                   residential precinct
      surrounding premises                      -12 metres; otherwise
      including privacy, views and
                                             3. 10 metres.
      access to sunlight.

                                      AO16.2                              Not applicable
                                      Where excavation is required,       The proposal is within an
                                      the maximum portion of the          existing building. No excavation
                                      exposed external façade of the      is proposed.
                                      building cannot exceed the
                                      respective building heights in
                                      AO16.1.


                                      Editor's Note—refer to figure
                                      AP3-13A to measure height in
                                      storeys.

Used in these records

About this file

File size
551 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Code Assessment.pdf · 551 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.