      Fauna Management
86.   Vegetation must only be removed or disturbed in accordance with a Fauna Management
      Plan (or part thereof) prepared by a qualified person* and endorsed through an Operational
      Works approval.
      *(Refer to Advisory Note)
      Bushfire Management
87.   The development must be carried out in accordance with Bushfire Hazard Assessment and
      Management Plan v4 prepared by North Coast Environmental Services dated 06/09/2024,
      which must be amended to include:
      a.    Revised plans that incorporate the latest architectural plans that show the clamping
            infrastructure wholly outside of the Noosa plan Bushfire hazard mapping potential
            impact buffer.
      b.    Section 5.3 Water Supply is to be updated to include a minimum of 20,000 litres of
            dedicated static water supply for firefighting purposes for each group of 7 cabins. The
            last paragraph of this section needs to be updated as an error is present “shared
            between 2 cabins’ This should read 7.
      c.    Revised plans that demonstrate a minimum 10,000 litres of dedicated static water
            supply for firefighting purposes is available at the shelter in place location.
      d.    Revised plans that incorporate the recommended fire access trail within Lot 394
            M371117 (see Plate 23 of the Bushfire Hazard Assessment and Management Plan)
            and extending along the southern boundary until it meets the eastern boundary of the
            subject site, before gaining access to Road 176.
      e.    Detail that the fire access trail along the southern boundary is to be used for emergency
            access only.
      The report must be resubmitted and approved by Council incorporating the above
      amendments prior to the issue of any Development Permit for Operational Works.*
88.   The development must be carried out in accordance with Bushfire Evacuation Plan v4
      prepared by North Coast Environmental Services and dated 06/09/2024, which must be
      amended as follows
      a.    Revised plans that that incorporate the latest architectural plans that shows the internal
            evacuation route that connects directly between the shelter in place building and the
            clamping infrastructure.
      b.    Section 8 Evacuation Triggers, to be updated to include:
            i.    Daily review of FDR forecasts for the Southeast Coast which are available from
                  the Bureau of Meteorology
            ii.   Evacuation of all guests and non-essential staff prior to the commencement of
                  any day with a forecast FDR rating of Extreme or Catastrophic.
      c.    Section 7 Evacuation Routes, to incorporate detailed plans of the secondary
            emergency access and associated maintenance requirements.
      The report must be resubmitted to Council incorporating the above amendments prior to the
      issue of any Development Permit for Operational Works.*
      *(Refer to Advisory Note)
89.   The site must be provided with water storage reservoirs for emergency firefighting purposes
      in accordance with the amended Bushfire Hazard Assessment and Management Plan. Such
      storage must be provided in addition to the water supply capacity required for the use and
      must be provided in the form of a static water supply tank. If by rainwater tank, water storage
      for firefighting purposes must be provided either in a separate rainwater tank or a reserve
      section in the main water supply tank on which:
Log in to download the original file

Council Report 131998 981211 5 Amended proposal.pdf · 1.8 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.