WATER QUALITY & DRAINAGE CODE
Performance Criteria and Acceptable Solution
Noosa Civic Stage 2 Retail Development
29 September 2023
PERFORMANCE OUTCOMES ACCEPTABLE OUTCOMES RESPONSE
quality objectives are prescribed in Schedule 1 of the 2. transferred off-site for treatment/disposal to an
Environmental Protection (Water) Policy 2009. appropriately licenced facility;
3. reused on-site in a closed-cycle irrigation scheme,
industrial processes, washing or cleaning or other
purpose; or
4. treated to meet the drinking water supply
environmental values prior to release.
Editor’s Note—The Plumbing and Drainage Act 2003 sets
out requirements for wastewater management.
PO16 AO16 No onsite treatment systems are proposed as part of the
On-site effluent treatment and disposal systems are development.
designed, constructed and managed to not compromise the An onsite effluent system and disposal area is:
environmental values of waters and water quality objectives.
1. not located on a slope greater than 1 in (10%);
2. not located at or below the 1% annual exceedance
probability (AEP flood event);
3. not located within a riparian buffer area mapped on
a Biodiversity, Waterways and Wetlands Overlay
Map; and
4. setback 400 metres minimum from the full supply
level of Lake Macdonald.
Editor’s Note—The Plumbing and Drainage Act 2003 sets
out requirements for on-site effluent treatment and
disposal. The Queensland Plumbing and Wastewater Code
and associated guidelines are used to confirm the suitability
of each site to accommodate an on-site sewerage facility; or
where a centrally located group collection treatment system
is proposed, confirmation as to the suitability of the
designated site to accommodate the on-site sewerage
facility. Additionally, where the combined total peak design
capacity of effluent treatment is less than 21 equivalent
persons, the design of the system achieves a low to medium
risk classification in accordance with Seqwater’s Land Use
Risk Tool for onsite sewerage facilities.
https://mpncnetau.sharepoint.com/sites/administration/shared documents/9000-9999/9900-9999/9954/codes/29-09-23 water quality & drainage code.docx
Page 10
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix C- Civil Engineering Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.