131001 Minor Change Request · 132006.268.03
Attached to the e-mail Pre-Request for Minor Change to MCU - 132006.268.03.
future-plus
ENVIRONMENTAL
4377-131119-1.0
Wastewater Treatment Comments
All wastewater generated from the dwelling and factory office
facilities are to be diverted to the existing septic tank located
geographically downslope of the waste generating facilities. The
Treatment Standard:
existing septic tank is to be converted to a pump station, with all
collected wastewater pump to an STP capable of treating the
wastewater to a Secondary or Advanced Secondary standard.
Land Application System: Surface (heavy droplet) Irrigation System
Land Application Area: 500m2 irrigation area
In accordance with those contained within the Queensland Plumbing
Setback distances:
and Wastewater Code
A diversion drain/bund and/or cut-off drain is to be constructed up
slope of the land application area in order to intercept both surface
and sub-surface water prior to entering the land application area.
A retention mound is to be constructed downslope of the land
application area to prevent any surface water from exiting the
designated disposal area.
System Recommendations:
Grease trap to be installed.
Existing Septic System to be converted to a pump station. Effluent to
be pumped to the new STP. Locate sanitary drainage line from office
facilities I toilets and plumb to pump station.
February 2014 Site & Soil Evaluation Report 14
Wastewater Treatment and Effluent Disposal
314 Cooroy Mountain Road, Cooroy Mountain
34
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
131001 Minor Change Request.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.