Installation Notes:
-ÿversion Crain/IVbmd 1) This drawing must be read in conjunction with the corresponding
-Max spacing
SOOOrrm Dstribution laterals wth abow ground sprinkler heads Future - Plus Environmental report.
2) All work must comply with AS/NZ 1547, Queensland Plumbing
and Wastewater Code, Standard Plumbing and Drainage Regulation
Retention Crain/IVbmd 200S,Plumbing and Drainage Act 2002 and Local Council guidelines
ISOmmrrin 3) The wastewater generated by the Domestic Dwelling and
Factory Office Facilities is to be diverted to the existing Septic tank. The
existing Septic tank is to be converted to a pump station. AH collected
wastewater is to be pumped to the new STP.
4) Delivery pipe should be lilac stripe 25mm or similar poly pipe
and buried to a minimum of 150mm
5) A filter is to be installed on the delivery line to prevent clogging
of the sprinklers
6) A check valve is to be installed on the delivery pipe
7) A distribution valve is to be installed (located upslope of the
irrigation area) to provide even distribution to the irrigation areas and to
the laterals
o-maope 8) Any depressions within the irrigation area are to be filled with soil
of same category as horizon A
9) Laterals must be laid parallel with the natural contours of the land
10) Control valves are to be placed on each sprinkler to ensure even
distribution
r-DN^rsion Crain/Mxnd 11) Sprinklers should be spaced 5m apart and no less than 2.5m from
i—Cut Off Drain the irrigation area boundary
12) A diversion drain/mound is to be constructed upslope of the
irrigation area
Low plim-large heavy
13) A retention mound is to be constructed downslope of the
droplet dorre sprinkler
irrigation area
14) All stormwater is to be diverted away from the proposed irrigation
area
15) Where not already established introduce suitable, non-invasive,
vegetation that is tolerant to wet conditions and has a high
evapo-transpiration capacity. Seek advice from your local nursery
16) Where not already established turf or mulch is to be applied to the
irrigation area
17) All vehicles and hooved animals are to be kept off the irrigation
Sqang Ste - geder than 1:10 area
wiere dcpe exceeds ICP/oacMoe is to be 18) A minimum of two warning signs should be placed within each
soixjTt frcm FFE prior to instsllstion irrigation area
>10%3Gpe
Non-inucEMB, trees, shnte, gouxl
Standard Drawing
cx>^ and tuf aited to vvet oordtions
future-plus Siifaoe Irrigation System and the L|3takB of nutrients are to be
ENVIRONMENTAL
Cooroy Mountain Spring used in the irrigation area
Rgje [\/feasLremsrts to Take
FPE Ref: 4377-131119-1. OScale: Ftesdenoe Q/a-Srale IVfeasuHTErts
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
131001 Minor Change Request.pdfRelated documentApplication case desk ↗
About this file
- File size
- 4.4 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.