Bushfire attack from assessment reference point A, I and J
• Forest fire danger index – 48
• Vegetation - VHC 22.1 Melaleuca open forests on seasonally inundated lowland and coastal
swamps
• Understorey fuel load – 28.4 t/ha1
• Total fuel load – 38.4 t/ha2
• Effective slope – 0° slope
• Site slope – 0° slope
• Flame width – 100 m
Note 1. Fuel load taken from Bushfire Resilient Communities Technical Reference Guide for the State Planning Policy State Interest
‘Natural Hazards, Risk and Resilience – Bushfire’ 2019 (Bushfire resilient communities).
2. 10 t/ha has been added to understorey fuel to account for overstorey fuel load when determining total fuel load. This approach
is more conservative than what is required by Bushfire Resilient Communities, but it has been followed to be consistent with the
descriptions of understorey and overstorey in the Australian Standard (AS 3959-2018) Construction of buildings in bushfire prone
areas.