230213 - Unit 29, 86 Noosa Parade, NOOSA HEADS - Architectural Plans
Plans and drawings: the text below has words only, no drawings.
GENERAL NOTES:
DRAWINGS PROVIDED ARE FOR ARCHITECTURAL DESIGN PURPOSES ONLY. CONSTRUCTION
MUST REFER TO STRUCTURAL ENGINEERING DOCUMENTATION AND LOCAL BUILDING CERTIFIER
FOR CORRECT BUILDING METHOD, MATERIALS ETC. IN NO WAY ARE THESE DRAWINGS TO BE
USED FOR CONSTRUCTION.
DRAWINGS TO BE READ IN CONJUNCTION WITH OTHER CONSULTANTS DOCUMENTATION.
REFER ANY DISCREPANCIES TO THE RELEVANT CONSULTANT FOR WRITTEN DIRECTION.
THIS SET OF PLANS IS SUFFICIENT TO OBTAIN A BUILDING PERMIT; HOWEVER, ALL
MATERIALS AND METHODS OF CONSTRUCTION NECESSARY TO COMPLETE THE PROJECT
ARE NOT NECESSARILY DESCRIBED. THE PLANS DELINEATE AND DESCRIBE ONLY LOCATIONS,
DIMENSIONS, TYPES OF MATERIALS AND GENERAL METHODS OF ASSEMBLING OR FASTENING
AND OTHER CONSULTANTS DOCUMENTATION SPECIFIES THE PARTICULAR PRODUCTS,
MATERIALS AND TYPE OF CONSTRUCTION RECOMMENDED FOR THIS DESIGN.
DIMENSIONS TAKE PRECEDENCE OVER SCALED MEASUREMENTS. DETAILS AND SECTIONS ON
THE DRAWINGS ARE SHOWN AT SPECIFIC LOCATIONS AND ARE INTENDED TO SHOW GENERAL
REQUIREMENTS THROUGHOUT. DETAILS NOTED "TYPICAL" IMPLY ALL LIKE CONDITIONS
TREATED SIMILARLY, UNLESS NOTED OTHERWISE. THE ARCHITECTURAL DETAILS SHOWN ARE
INTENDED TO FURTHER ILLUSTRATE THE VISUAL DESIGN CONCEPT AND THE MINIMUM
RECOMMENDED WEATHER PROTECTION FOR THIS PROJECT. BUILDING CODE REQUIREMENTS,
OTHER CONSULTANTS DOCUMENTATION AND PRODUCT MANUFACTURER'S WRITTEN
INSTRUCTIONS SHALL ALSO BE CONSIDERED IN ORDER TO COMPLETE THE CONSTRUCTION OF
THE DETAILS, AND IN SOME CASES MAY SUPERSEDE THE DETAILS.
THE BUILDER AND ALL SUB CONTRACTORS SHALL REVIEW THE FULL CONTENT OF THE PLANS
FOR DISCREPANCIES AND OMISSIONS PRIOR TO COMMENCEMENT OF WORK. THE BUILDER AND
SUB CONTRACTORS SHALL BE RESPONSIBLE FOR ANY WORK NOT IN CONFORMANCE WITH THE
PLANS OR IN CONFLICT WITH ANY RELEVANT CODE.
ALL CONSTRUCTION SHALL COMPLY WITH THE MOST STRINGENT REQUIREMENTS OF ALL
CURRENT APPLICABLE STATE AND COUNCIL LAWS, RULE, CODES AND REGULATIONS. IF THE
BUILDER OR ANY SUB CONTRACTOR PERFORMS ANY WORK IN CONFLICT WITH THE ABOVE
MENTIONED LAWS, THEN THE CONTRACTOR IN VIOLATION SHALL BEAR ALL COSTS OF
REPAIR ARISING OUT OF THE NON-CONFORMING WORK.
THE BUILDER IS RESPONSIBLE TO CHECK ALL EXISTING SERVICES PRIOR TO BEGINNING
CONSTRUCTION. BUILDER TO VERIFY PROPERTY BOUNDARIES AND BUILDING LINES PRIOR
TO COMMENCEMENT OF WORKS IN ASSOCIATION WITH APPROVALS.
ALL SERVICES INCLUDING FIRE FIGHTING SERVICES, OCCUPANT WARNING SYSTEMS,
LIGHTING, POWER, WATER SUPPLY, SANITARY DRAINAGE, STORMWATER, MECHANICAL
VENTILATION AND AIR CONDITIONING TO BE IN ACCORDANCE WITH RELEVANT
CONSULTANTS DETAILS.
ALL STRUCTURAL ELEMENTS TO BE IN ACCORDANCE WITH ENGINEERS DESIGN AND DETAILS.
WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH RELEVANT CURRENT,
SAA CODES AND STATUTORY AUTHORITIES REQUIREMENTS.
ANY ADDITION OR DELETION OR CHANGE IN THE SCOPE OF WORK DESCRIBED BY THE PLANS
SHALL BE BY WRITTEN APPROVAL TO THE RELEVANT CONSULTANT.
EXISTING SITE CONDITIONS & PROPOSED DESIGN TO BE CONFIRMED ON SITE WITH BUILDER &
ENGINEER PRIOR TO CONSTRUCTION OR ORDERING OF ANY MATERIALS.
ALL DIMENSIONS & HEIGHTS TO BE CONFIRMED ON SITE WITH BUILDER PRIOR TO CONSTRUCTION
OR ORDERING OF ANY MATERAILS. RETAINING WALL HEIGHTS TO BE CONFIRMED ON SITE WITH
ENGINEER & BUILDER PRIOR TO CONSTRUCTION.
COLLINS BUILDING DESIGNS IS IN NO WAY RESPONSIBLE FOR ESTIMATIONS MADE FROM THESE
DRAWINGS THAT DIFFER FROM ACTUAL COSTINGS. BUILDER IS RESPONSIBLE FOR ALL COSTING
VARIATIONS AND EXTRAS THAT ARISE FROM CONSTRUCTION.
IT IS THE RESPONSIBILITY OF THE BUILDER TO ENSURE ALL RELEVANT TRADES HAVE UP TO DATE
DRAWINGS. NOTIFY ALL PARTIES IN WRITING OF ANY/ALL CHANGES MADE FROM ANY OTHER
TRADE AT ANY TIME AS SOON AS A CHANGE IS MADE.
ALL CADASTRAL/TOPOGRAPHY DATA (RLs,BOUNDARIES,CONTOURS,SERVICES ETC) SHOWEN HAS
BEEN PROVIDED FROM INTERNET MAPPING SITES AND IS NOT ACCURATE. IT IS THE
RESPONSABILITY OF THE BUILDER TO ENSURE A LICENCED SURVEYOR HAS CARRIED OUT A
SURVEY TO ENSURE CORRECT SETOUT,HEIGHTS,DEPTHS ARE ACCURATE AND COMPLY WITH
LOCAL AND STATE LAWS & REQUIREMENTS. THE BUILDER IS TO ENSURE THE SURVEY IS
PROVIDED TO COLLINS BUILDING DESIGNS & ALL OTHER SUB CONTRACTORS/PROFFESIONALS
ALONG WITH ANY DESCREPANCIES IN WRITING PRIOR TO ANY CONSTRUCTION.
ALL CABINETRY SHOWN ARE A CONCEPT DESIGN ONLY AND IT IS THE RESPONSIBILTY OF THE
BUILDER & CABINET MAKER TO CARRY OUT A CHECK MEASURE PRIOR TO ANY CONSTRUCTION.
CABINET MAKER TO ADJUST DESIGN TO SUIT APPLIANCES, FIXTURES AND FITTINGS CONFIRMED
WITH BUILDER.
WINDOW & DOOR SCHEDULE IS A GUIDE FOR QUOTING PURPOSES ONLY AND IS THE
RESPONSIBILTY OF THE BUILDER AND WINDWO/DOOR SUPPLIER TO ENSURE A CHECK MEASURE
IS CARRIED OUT PRIOR TO ANY ORDERING OR MANUFACTURING.
As Constructed
Proposed alerations & additions
Unit 29 Noosa Shores Resort
collinsbuildingdesigns.com.au
Date: 21.07.2023
QBCC # 15034167 Mob: 0474 141 348
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalFull text of the other 2 pages
Page 2
3339 3955 130 705 2898
130 600 944 130 534 130 1225 130
130
1810
1474
Kitchen
2267
3601 1804 534 915 705
Bed 2
These are not structural/load
3324
bearing walls
970
710
Dining
1057
These structural/load 3603
872
bearing walls remain
3693
130
130
7110
738
960
1728
5800
Ldry/Bath
Living
3656
130
Bed 1
3056
WC
1798
1800 250 4301 130 1773 130 960 130 3603
As Constructed
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project
Check all dimensions on site. All REV. DATE DESCRIPTION
Existing & Demolition Floor Plan Proposed alerations & additions
Building works must comply with Unit 29 Noosa Shores Resort
current B.C.A & A.S Standards Orientation:
Client:
All drawings are copyright and Louise Johnson Scale: 1 : 50 @ A3 Drawing No:
are owned and controlled by
Collins Building Designs. QBCC
Licence #15034167 - Mitchell [email protected]
Mob: 0474 141 348
Date: 21.07.2023 Rev: A01_ A102
Page 3
11027
4317 722 2255 130 3603
4187 130 2977
1200
250
600
oven
fridge
1810
cktop
705
2314
2444
Robe
Owners Study/
Kitchen Bed 2
Lockable Store Rm
3324
770
130
600
872
880
Dining
1010
872
130
7110
River Front
Balcony
1728
5800
5800
3294
Ldry/Bath
3656
130
Bed 1
Living WC
Robe
1798
1800
500
250
wall thickness tbc
on site with builder
1800 250 4301 130 1773 130 960 130 4693 3603
13077
As Constructed
Do not scale off this drawing. DRAWING REVISIONS Drawing Title: Project
Check all dimensions on site. All REV. DATE DESCRIPTION
Proposed Floor Plan Proposed alerations & additions
Building works must comply with Unit 29 Noosa Shores Resort
current B.C.A & A.S Standards Orientation:
Client:
All drawings are copyright and Louise Johnson Scale: 1 : 50 @ A3 Drawing No:
are owned and controlled by
Collins Building Designs. QBCC
Licence #15034167 - Mitchell [email protected]
Mob: 0474 141 348
Date: 21.07.2023 Rev: A01_ A103