Skip to the record
NoosaWatch™: The source of truth.

Council archive · source document

180078 - Resort Entry Drawing · 51901.3604.01

of 18

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

Very large file (29.7 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.

Materials and Finishes Schedule




1.      General Notes                           1.       General Notes                        2.    Notes to External Windows and          2.    Notes to External Windows and            BALUSTRADES                               DOWN PIPES
                                                                                              Doors                                        Doors
1.01   All shall be in accordance with the      1.11   All elements specified to be                                                                                                       BAL-02 Glass Balustrade                   DP-1     90mm Diameter Down Pipes
       accompanying drawings and to the                painted or powdercoated are to be      2.05 All dimensions ot be be checked on      2.12 Fall protection: where window or
       satisfaction of the Architect.                  in accordance with Architect’s final        site prior to manufacturing.                 door openings are on a floor more                 Frameless glass balustrade                 Colorbond downpipe 0.48mm
                                                       colour scheme.                                                                           than 2000mm above the adjacent                    panels. Rebated glazing                    basemetal thickness (BMT)
1.02   Refer any discrepancies to the                  Contractor to provide Architect 14     2.06 Window & door sizes are nominal.             surface below, and the lowest                     channel or grout fixed
       Architect for written instruction.              days notice before the final                Contractor to ensure windows and             openable portion of the window or                 connections to be confirmed by             Colour:TBC
                                                       selections are required.                    doors are fabricated to match                door is less than 1700mm above                    contractor. Allow for minimal
1.03   All work and materials shall be in                                                          constructed framing / surround
       accordance with the Building Code                                                                                                        that floor, the window or door shall              aluminium channel fixed to
                                                       For site painting generally apply 2         dimensions and allow for packing             be protected in accordance with                   glass in lieu of handrail.        FLOORS
       of Australia, the relevant Australian                                                       out of walls to accommodate door /
       Standards, the applicable codes                 finishing coats over recommended                                                         BCA 3.9.2.5 Prevention of Falls.                                                    FLF-01   Stone tile on new concrete
                                                       undercoat following appropriate             window frame depths.                                                                           Minimum height: 1200mm
       and regulations of the destination                                                                                                  2.13 Insect / fire screens shall be                                                               slab
       country and local council’s                     priming of surface.                                                                                                                        above finished floor level.
                                                                                                    All door sills to be set down where         “Crimsafe” woven stainless steel,
       requirements. Any discrepancy or         1.12   All exposed fixings, plates, screws,         possible (unless noted otherwise).          unless noted otheriwse.                                                                      Concrete slab as per Engineers
       ambiguity shall be referred to the                                                                                                                                                         Powder coated aluminium                    Drawings and specifications.
                                                       nails and the like to be 316 grade           Builder to allow for set down to                                                              channel.
       Architect for written direction.                stainless steel where appropriate or         concrete slabs where possible to       2.14 Door and window hardware shall be
                                                       unless otherwise noted. Structural           ensure all doors opening onto               as noted within the Door and                                                                 Tile: T-1
1.04   Any proposed changes to                                                                                                                  Window Schedule                                   Finish: Powdercoat
       materials, finishes, colours etc from           connections shall be as Engineer’s           external spaces finish flush with                                                             Colour: Duratec Dulux Zeus        FLF-02   Steel troweled concrete
       those specified must be approved                Drawings. Use dome head or                   internal finished floor level.                                                                Black
       by the Architect PRIOR to ordering.             countersunk fixings (as                                                             2.15 All external windows and doors are                                                           Structural slab as Engineers
                                                       appropriate) wherever possible.              Note: Scheduled door heights do             to be keyed alike with the entry                  Glass to comply with AS 1288               Drawings laid to falls as
1.05   The Client recognises that                      Ensure separation of different                not allow for set downs.                    door.                                             and relevant wind loading;                 indicated.
       unauthorised changes to the                     metals via rubber, neoprene                                                                                                                Glass colour: clear
       project are not the responsibility of           gaskets, sleeves and/or silicon        2.07 Contractor to ensure that all
                                                                                                                                           BALUSTRADES                                                                                       Colour: Natural grey with
       the Architect and releases the                  joins.                                      window & door head heights are at
                                                                                                   a single RL datum across the entire                                                    CEILINGS                                           standard aggregate.
       Architect from any liability arising                                                                                                BAL-01 Aluminium Balustrade
       from the construction, use or result     1.13   If in doubt please ask!                     building, unless noted otherwise .                                                     CLG-1 Flush Plasterboard Ceiling
                                                                                                   Notify Architect if this requires any                                                                                                     Finish: Steel troweled - Water
       of such changes.                                                                                                                              Fabricated aluminium
                                                2.    Notes to External Windows and                full height doors or windows to be                                                                                                        and UV resistant clear matt
                                                                                                                                                     balustrade in accordance with               PB-3 on battens direct to
1.05   All work referred to in this schedule    Doors                                              non-typical height                                                                                                                        penetrating sealer to
                                                                                                                                                     Architects Drawings.                        underside timber framing above.
       is by Builder, unless noted                                                                                                                                                                                                           manufacturers specifications.
                                                2.01 Door and Window Schedule shall           2.08 Glazing types and thickness are all                                                           Flush join sheets throughout.
       otherwise. Work noted by “Joiner”                                                                                                             All connections to be fully                 Square set perimeter throughout.   FLF-5    Exposed aggregate concrete
       or other specialist contractor is to          be read in conjunction with                   to comply with AS 1288.
                                                     Architectural Drawings. Any                                                                     welded. Pin fixed connections
       be attended upon by the Builder.                                                            Generally to be “Veridian” ‘Comfort
                                                     variations from this schedule must                                                              to footing below as required. All           Finish: PT-4                                Structural slab as Engineers
                                                                                                   Plus’ in colour “Clear” unless noted
1.07   No material, finish or item used in           be notified to the Architect prior to                                                           fixings to be 316 stainless steel.                                                      Drawings laid to falls as
                                                                                                   otherwise.                                                                             CLG-2 Suspended plasterboard
       the project may include any                   ordering                                      Where safety markings are required,                                                                                                       indicated.
                                                                                                                                                     Details to be discussed with               ceiling                                      Colour: Natural grey with
       asbestos or hazardous or toxic                                                              provide surface transfers only in
                                                2.02 All doors and windows shall be                                                                  architect prior to manufacturer.                                                        standard aggregate.
       substances or materials.                                                                    accordance with the Standard.                                                                 PB-4 screwed up to suspended
                                                     fabricated to suit the required Wind
                                                     Loading and Impact loading where              Generally avoid safety markings.                                                              metal battens on hanging grid
1.08   All materials, adhesives, applied                                                                                                             Finish: Powdercoat                                                                      Finish: Exposed - Water and UV
       finishes and other chemical based             required.                                                                                       Colour: Duratec Dulux Zeus                  suspended from framing above.               resistant clear matt penetrating
                                                                                              2.09 Louvres generally shall be
       products such as paint systems                                                                                                                Black                                       Flush join sheets throughout.               sealer to manufacturers
                                                                                                   “Breezeway Altair” with
                                                2.03 Aluminium window and door joinery                                                                                                           Square set perimeter throughout.
       should be “0 VOC” unless                                                                    “Stronghold’ system unless noted                                                                                                          specifications.
                                                     shall be commercial /architectural                                                              TO COMPLY WITH
       otherwise approved by Architect.                                                            otherwise.
                                                     series sections; narrowest possible                                                             QUEENSLAND POOL SAFETY                      Finish: PT-4                       FLF-6    Driveway
1.09   All materials and products                    profile to be used. Proposed series                                                             CODE
                                                     to be approved by Architect prior to           Blades shall generally be 152 wide                                                    CLG-3 Exposed Concrete
       incorporated into the works shall                                                            where possible; 102 where fall                                                                                                           Structural slab as Engineers
       be fit for purpose and installed in in        ordering.                                                                                                                                                                               Drawings laid to falls as
                                                                                                    protection is required. Refer                                                                Underside of Class 2 slab above.
       accordance with manufacturers                                                                Materials Schedule for blade types.                                                                                                      required.
       instructions to comply with                     Finsh: shall powdercoat, unless                                                                                                           Off-form finish, smooth face
       warranty obligations. Copies of all             noted otherwise. Powdercoating                                                                                                            formwork. Square edges with no              Colour: TBC
                                                                                              2.10 All fixings of windows and doors to
       relevant warranties shall be                    shall be “Interpon D2015” series                                                                                                          fillets. V drip groove to all
                                                                                                   be 316 grade stainless steel.
       supplied to all contracting parties.            applied by an authorised                                                                                                                  external soffit edges. Reinforcing            Finish: Exposed - Water and UV
                                                       fabricatotor. Colour shall be as       2.11 Stacking doors to stack so that they                                                          as per engineers specifications.            resistant clear matt penetrating
1.10   All timber, including bamboo, must              Architect’s material reference.             are flush with the jamb when open,                                                                                                        sealer to manufacturers
       be FSC (Forest Stewardship                                                                  offering full egress opening.                                                                  Finish: Water and UV resistant              specifications.
       Council) Certified or recycled.          2.04 ALL WINDOW AND DOOR DETAILS                                                                                                                 clear matt penetrating sealer to
       Rainforest timbers are not to be              ARE TO BE CONFIRMED WITH                                                                                                                    manufacturers specifications.
       used. Copper Chrome Arsenic                   NOMINATED SUBCONTRACTOR
       (CCA) treated timber is not to be             PRIOR TO DESIGN FABRICATION.
       used.                                         Advise Architect if a non-typical
                                                     section is required for any particular
                                                     item.

Used in these records

About this file

File size
29.7 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

180078 - Resort Entry Drawing.pdf · 29.7 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.