Concrete block retaining wall to be in Swimming pool to be in accordance with engineers design Timber frame truss roof to Eng. Roof insulation achieve the Min. Timber framed ceiling/bulkheads Colorbond Custom Orb roof
accordance with structural engineers and detail. All pool and spa construction to be in accordance detail and installed to man. spec 'R' rating in accordance with with square set plaster board sheeting 'Surfmist'
design and detail. Provide with manufacturers/installers specifications. Pool to have NCC 2019 Vol. Two sheeting.
waterproofing system to back of wall suitable pumps in accordance with manufacturers/installers
with ag drain and free draining backfill. specifications. Provide pool fence to be in accordance with
NCC 3.9.3, the Building Act 1993, Building Regulation 2006,
Timber frame truss roof to Eng. Roof insulation achieve the Min. Colorbond Custom Orb roof AS 1926 . Pool fence to be min. 1200mm high above
detail and installed to man. spec 'R' rating in accordance with sheeting 'Surfmist' adjoining finished surface level and have 900mm non climbing
NCC 2019 Vol. Two zone as specified in pool legislation www.zestbuildingdesign.com.au
8m HEIGHT LIMIT
9960 Colorbond half round gutters &
RL 48.666 m Colorbond fascias 'Surfmist'
RL 48.702 m
°
20.0
Aluminium hood installed to RL 47.428 m 8m HEIGHT LIMIT
man. spec.
BOUNDARY
4109
BOUNDARY
BOUNDARY
60/600/60 fire separation wall - 10.0° 10.0°
BOUNDARY
cladded with 150mm Weathertex - 7414 1m timber balustrade wall with
Weathergrove Natural cladding selected timber top capping. Painted
Aluminium hood UNIT 2 - CEILING
installed to man. spec. 10752 RL 46.050 m
Raised planter box
TOW. 44.550 m TOW. 44.550 m
TOW. 42.489 m 8500
2550
Timber pergola with decorative
UNIT 1 - LVL 2 6339 fretwork to detail. Painted
RL 44.500 m
RL 43.200 m
TOW. 42.950 m RL 43.200 m TOW. 42.142 m 10.7°
1800mm High Timber screening fence to detail
UNIT 2 - LVL 2
timber pailing 1000 9742 RL 43.500 m
4965
fence along UNIT 1 Timber pergola with decorative fretwork
entire boundary
NGL
to detail. Painted Lexicon Half
TOW. 41.650 m
UNIT 2 TOW. 41.750 m
3000
1000 COMPACT FILL
UNIT 1 - LEVEL 1 2325
RL 41.500 m
TOW. 40.200 m
Garage Level Garage Level
RL 40.500 m RL 40.500 m
NGL
COMPACT FILL
Concrete block retaining wall to be in Rendered block wall to Eng. Footings and slab construction shall to be in accordance with engineers design Concrete driveway to Eng. design and detail. Timber screening fence to detail Rendered block wall to Eng.
accordance with structural engineers detail - selected paint finish and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance Driveway to comply with AS2890.1. Provide new detail - selected paint finish
design and detail. Provide with engineers design and detail and as 2870. Termite barriers to comply with crossover in accordance with local authority Cut and fill ratios and grade to Suspended timber floor to Footings and slab construction shall to be in accordance with engineers design Concrete driveway to Eng. design and detail.
waterproofing system to back of wall as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to regulations. Driveway grades to be in accordance Civil ENG. detail ENG. details and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance Driveway to comply with AS2890.1. Provide new
with ag drain and free draining backfill. perimeter and penetrations of slab to be designed and installed by specialist with AS2890.1. Driveway to be in selected with engineers design and detail and as 2870. Termite barriers to comply with crossover in accordance with local authority
approved contractor - guarantees are required by the owner from the coloured exposed aggregate concrete blend with, as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to regulations. Driveway grades to be in accordance
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) provide slip resistant clear penetrating sealer to perimeter and penetrations of slab to be designed and installed by specialist with AS2890.1. Driveway to be in selected
under slab with 200mm laps. securely tape joint entire driveway and applied in accordance with approved contractor - guarantees are required by the owner from the coloured exposed aggregate concrete blend with,
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) provide slip resistant clear penetrating sealer to
1 Section manufacturers specifications.
2 Section under slab with 200mm laps. securely tape joint entire driveway and applied in accordance with
Unit 1 - Section A 1 : 100 A.100 Section 2 1 : 100 manufacturers specifications.
Disclaimer: Zest Building Design Pty. Ltd. retains all
common law, statutory law and other rights including
1m timber balustrade wall with Colorbond Custom Orb roof 60/600/60 fire separation wall. Timber frame truss roof to Eng. Roof insulation achieve the Min. copyright and intellectual property rights in respect of this
1m timber balustrade wall with Colorbond Custom Orb roof 60/600/60 fire separation wall. Timber frame truss roof to Eng. Timber framed ceiling/bulkheads
selected timber top capping. Painted sheeting 'Surfmist' detail and installed to man. spec 'R' rating in accordance with document.
selected timber top capping. Painted sheeting 'Surfmist' detail and installed to man. spec with square set plaster board
sheeting. NCC 2019 Vol. Two
Colorbond half round gutters & Colorbond half round gutters & The recipient indemnifies Zest Building Design Pty. Ltd.
Colorbond fascias 'Surfmist' Timber framed ceiling/bulkheads Colorbond fascias 'Surfmist' against all claims resulting from use of this document for
Colorbond half round gutters & Roof insulation achieve the Min.
any purpose other than its intended use, unauthorized
Colorbond fascias 'Surfmist' 'R' rating in accordance with with square set plaster board
changes or reuse of the document on other projects without
RL 48.985 m NCC 2019 Vol. Two sheeting.
RL 48.668 m the permission of Zest Building Design Pty. Ltd.
Colorbond half round gutters &
20.0 Colorbond fascias 'Surfmist' Under no circumstance shall transfer of this document be
°
20.0 °
BOUNDARY
deemed a sale or constitute a transfer of the license to use
° 20.0
RL 47.522 m 20.0 ° this document.
8m HEIGHT LIMIT
BOUNDARY
BOUNDARY
BOUNDARY
3638 8m HEIGHT LIMIT Revisions
RL 46.298 m 5386
10.0°
UNIT 2 - CEILING UNIT 2 - CEILING
RL 46.050 m RL 46.050 m
3976 Concrete block retaining wall to be in 5157
BED 4 BED 3
Timber post to ENG. spec. painted
4240 accordance with structural engineers ENS BED 1 BALCONY TOW. 44.550 m
design and detail. Provide TOW. 44.550 m 1m timber balustrade wall with
UNIT 1 - LVL 2 TOW. 44.550 m BALCONY BED 2 BED 3
RL 44.500 m BALCONY waterproofing system to back of wall selected timber top capping. Painted
UNIT 1 - CEILING with ag drain and free draining backfill.
RL 44.200 m TOW. 42.950 m 3386
10.7° UNIT 1
UNIT 2 - LVL 2 UNIT 2 - LVL 2
RL 43.500 m Timber post to RL 43.500 m
3077
KITCHEN ALFRESCO 5948
ENG. spec.
Concrete UNIT 2 COMPACT FILL UNIT 2 UNIT 1 TOW. 41.950 m painted
stairs to detail 4986
1000 Timber post to GARAGE GARAGE
UNIT 1 - LEVEL 1
ALFRESCO BED 4 BATH ENG. spec.
UNIT 1 - LEVEL 1
RL 41.500 m painted RL 41.500 m
TOW. 40.430 m
TOW. 40.077 m
4349 1000
Garage Level Status
TOW. 39.744 m RL 40.500 m
1200 TOW. 39.744 m
Garage Level
RL 40.500 m NGL COMPACT FILL
Cut and fill ratios and grade to
2182
PERMIT ISSUE
Civil ENG. detail NGL Cut and fill ratios and grade to
Client
Civil ENG. detail
COMPACT FILL
IZAROX QLD PTY LTD
Concrete block retaining wall to be in Suspended timber floor to Footings and slab construction shall to be in accordance with engineers design Concrete block retaining wall to be in
Concrete block retaining wall to be in Suspended timber floor to Footings and slab construction shall to be in accordance with engineers design Swimming pool to be in accordance with engineers design
accordance with structural engineers ENG. details and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance accordance with structural engineers
accordance with structural engineers ENG. details and detail and ncc 3.2. Slab on ground is to be monolithic to be in accordance and detail. All pool and spa construction to be in accordance design and detail. Provide waterproofing with engineers design and detail and as 2870. Termite barriers to comply with design and detail. Provide
design and detail. Provide waterproofing with engineers design and detail and as 2870. Termite barriers to comply with with manufacturers/installers specifications. Pool to have
system to back of wall with ag drain and as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to waterproofing system to back of wall Project
system to back of wall with ag drain and as 3660.1 and ncc 3.1.3. approved 'kordon' termite barriers are required to suitable pumps in accordance with manufacturers/installers free draining backfill. with ag drain and free draining backfill.
perimeter and penetrations of slab to be designed and installed by specialist
free draining backfill. perimeter and penetrations of slab to be designed and installed by specialist
approved contractor - guarantees are required by the owner from the
specifications. Provide pool fence to be in accordance with
NCC 3.9.3, the Building Act 1993, Building Regulation 2006,
approved contractor - guarantees are required by the owner from the Brighton Springs
manufacturer / installer of the termite barriers. Provide moisture barrier (200um)
manufacturer / installer of the termite barriers. Provide moisture barrier (200um) AS 1926 . Pool fence to be min. 1200mm high above under slab with 200mm laps. securely tape joint
under slab with 200mm laps. securely tape joint adjoining finished surface level and have 900mm non climbing
zone as specified in pool legislation 73 SOUTHERNCROSS PRADE
SUNRISE BEACH, QLD 4567
3 Section 4 Section Drawing
Section 3 1 : 100 Section 4 1 : 100
SECTIONS
Project No Date Author
22004 13/09/2022 TW
Scale: @ A1 Drawing No. Revision
1 : 100 A.300
13/09/2022 5:47:42 PM