Appendix H - Slope Stability Assessment
Brett Hage 22328-001-Rev0
14 September 2022
Table 3: Details of Qualitative Risk Assessment for Property (AGS 2007
Assessed
Hazard Likelihood Consequence
Risk
Comments
Given the presence of stiff residual soils at the
natural surface, and stiff to very stiff XW materials
below at shallow depth, the rounded nature of the
spur crest where construction is proposed, and
minimal catchment for water above the site and
1: Proposed residence on
apparent lack of groundwater, and no evidence of
subdivided Lot 2- Failure
existing instability in the vicinity of the proposed
through fill materials natural Unlikely Medium Low
residence, it is considered Unlikely that a landslip
soils above the foundation
would develop, subject to implementation of the
depth
recommendations in Section 4 (particularly with
attention to remediation of existing fill). With a
potential Medium impact from such shallow
instability the resultant risk would be Low as per
AGS 2007.
The likelihood of a deep failure through the XW
materials or weathered meta-mudstone rock below the
2: Proposed residence on foundation depth is assessed as Rare due to the
subdivided Lot 2 - Deep strength of these materials, no evidence of existing
seated failure in XW material or Rare Major Low instability, and relatively consistent nature of the
weathered meta-mudstone sloping ground across the development area.
below the foundation depth Although the consequence of such a failure could be
Major, the resultant risk is Very Low as per AGS
2007.
The potential impacts on slope stability of the development components have been assessed, and the
measures recommended below in Section 4 have been designed to mitigate those impacts.
3.3 Quantitative Assessment
In order to calculate the factor of safety (FOS) against slope instability for the proposed building works for
proposed Lot 2, numerical analysis has been conducted using Slope/W. Based upon the results of our
investigation, an adverse ground profile was adopted, considering relatively high groundwater table
conditions (1 m BGL, noting that this was not recorded during our investigation), and larger scale, relatively
deep seated failure modes.
A 20 kPa surcharge load has been applied across the building envelope to represent a residence of up to
two storeys height.
Results of the numerical slope stability analysis are illustrated in Text Figure 9 overleaf.
9/19