Attached to the e-mail MCU14/0096 Development Application - Aquaculture 3 & 4 / 15 Production Street, Noosaville.

of 28

Page text shows just the words. Original shows the document exactly as it was published.

Page text read automatically using OCR, there may be inaccuracies

Proposal Report    Proposed Material Change of Use of Premises for Aquaculture (Animal Husbandry – Type 1 Traditional) at Units 3 & 4 at 15 Production
                   Street, Noosaville described as Lots 3 and 4 on SP184294 in CTS34929
Applicant:         Oceanic Technologies Pty. Ltd.


        Column 1                               Column 2                                                 Column 3
    Specific Outcomes                     Probable solutions                                           Assessment
                                         (if code assessable)
        access to premises              AND
        and       flood     free        S18.2 Where Council                       18.2 – Complies – drainage is to continue to
        habitable areas;                infrastructure is available—                   flow to the existing infrastructure.
 b)     allow only minor,                a)     any drainage
        short term and                          (including buildings
        infrequent flooding of                  and yards) flows to
        non-habitable areas;                    that infrastructure;
 c)     ensure drainage does                    and
        not adversely impact             b)     the infrastructure
        upon other premises;                    has the capacity to
        and                                     accept any
 d)     ensure filling or                       additional loading;
        excavation does not              AND
        adversely impact                S18.3 For Detached
        upon other premises             houses and Multiple
        by—                             housing—
    i. causing ponding on
                                            where slab on ground
          the site or nearby
                                              construction is used,
          land;
                                              filling does not
    ii. increasing flooding,
                                              extend more than 1m
          which adversely
                                              beyond the building
          affects the safety or
                                              footprint, measured
          use of any land
                                              from the outer walls
          upstream and
                                              of the building ; or
          downstream; and
    iii. adversely affecting                the design consists of a
          the flow of water in                 suspended floor
          any overland flow                    construction.
          path.
 Sloping sites & ridgelines
 O19 Development on                     S19.1 Buildings and                       N/A – The site is not a sloping site
 sloping sites—                         associated access ways
 a)     is responsive to the            are not constructed on
        natural topography of           land with a slope greater
        the site and                    than 25% (1 in 4);
        minimises cut and fill;         AND
 b)     does not visually               S19.2 Buildings are of split
        dominate the hill               level design that step down
        slope or interrupt the          the slope or have
        skyline;                        suspended floor
 c)     is integrated with the          construction;
        natural site                    AND
        characteristics                 S19.3 Cut or fill is less
        including vegetation;           than 1.2m in depth;
        and                             AND
 d)     for Multiple housing,           S19.4 The distance
        takes the form of               between the ground and
        small separate                  the lowest part of the floor
        buildings;                      of the building does not
                                        exceed 3m to avoid large
 AND                                    under building areas;
                                        AND
                                        S19.5 Buildings present no
                                        more than 2 or 3 storeys at
                                        any one point.

 O20 On steep slopes or                 S20.1 No solution provided                N/A – The site is not a sloping site
 ridgelines which are visible
 from the major road


      martoo consulting - Town Planners + Land Surveyors + Urban Designers + Development Managers                                                16
Log in to download the original file

D-01744-01-A Merged.pdf · 2.5 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.