20150162 - Plans A3 · 51994.1176.01
Attached to the e-mail 51994.1176.01 (TPC 2789) Request to Change Existing Approval - additions to Unit 1.
Plans and drawings: the text below has words only, no drawings.
REAL PROPERTY DESCRIPTION
Storm Water
Lot: 1 On: GTP 105789
Parish: Weyba Surface water drainage must be prevented from
County: March entering the building with fgl sloping 50mm over
Lot / Site Area (m²): 216 m² the first 1m away from the building & the finished
slab height at a minimum FFL 150mm above FGL or
Local Government: Noosa Shire Council minimum 100mm above FGL in sandy, well drained
areas of low rainfall intensity (Q20 125mm), or 50mm
Drawing Schedule above impermeable paved or concreted areas all
COMMON PROPERTY
STATUTORY INFORMATION: Current Revision in accordance with BCA Vol 2 P3.1.2.3
Building Classification: 1a Sheet No. Sheet Name Revision Date
Domestic driveway design requirements :
Storeys: 2 • 3m minimum width (AS 2890:2004 Amdt1,
Climate Zone: 3 SK.00 Cover Sheet B 19/05/15 S2.6.1)
Wind Category: N3 SK.01 Site Plan B 19/05/15 • Maximum 1 in 4 (25%) gradient (AS 2890:2004
SK.02 Exist / Demo & Proposed B 19/05/15 Amdt1, S2.6.2)
340
' 00"
Upper Floor Plan ° 54
252 10 m
°
General
51'
4.9 Changes in grade for straight driveways to prevent
SK.03 Elevations B 19/05/15
Do not scale from these drawings, figured
0 0"
vehicle scraping driveway require grade transitions
dimensions take precedence at all times - SK.04 Building Sections B 19/05/15
of 2m in length when:
5. 4 1
when in doubt consult the designer prior to Z3D.1 3D Image B 19/05/15 • Summit changes in grade is over 1 in 8 (12.5%)
0m
commencing construction. It is the Z3D.2 3D Image B 19/05/15 • Sag changes in grade is over 1 in 6.7 (15%)
builders responsibility to: Z3D.3 3D Image B 19/05/15 (AS 2890:2004 Amdt1, S2.5.3(d)
• Verify all dimensions and levels on site. Z3D.4 3D Image B 19/05/15
Builder is to follow the best practice
• Ensure all boundary setbacks are strictly guidelines for controlling stormwater
adhered to. pollution from building sites by local council
• Verify location and levels of all services on site.
.2400.
• Verify that floors and finished levels enable
Proposed addition Deck The builder is responsible to check all existing
connection to required services on site. services prior to beginning construction
Deck un-covered
• Real property information to be confirmed by
licensed surveyor prior to construction.
• Bearings have been corrected by modelling Existing
340
software to read in a clockwise direction. Adjoined
176° 00' 00"
°
40 '
This may cause discrepancies of 180 deg from
Residence
0 0"
original survey information.
• Site levels, driveway design & site works to
15.3
detail by others.
30 m
27.655 m
These drawings have been prepared for building
permit application only. It is the builder's / proprietor's
responsibility to further interpret the design and Existing
drawings to detail the project for construction. Residence
Y
Termites E RT
Protection against subterranean termites to be OP
in accordance with A.S. 3660 Part 1. (protection PR
of buildings from subterranean termites). ON
M
338 12 m
M
2. 8
Protection against subterranean termites to
CO
° 42
apply to all "primary building elements".
' 39
The builder is to provide physical barriers to
"
00 "
the entry by subterranean termites by 38'
70° 15 m
construction of all slabs & timber floor framing in Existing timber fence 3. 4
accordance with A.S. 2870.1 (Residential footing
6° 30' 00"
3.300 m
and slab construction). and A.S. 3600 (Concrete Existing
structures code). In addition all slab penetrations Driveway
are to be protected using stainless steel mesh.
(Termimesh or equivalent fitted to manuf. spec.).
5m
External perimeter barrier to be installed by 7. 44
"
' 00
T
excavation trenches, treating the exposed 00
71 °
trench and backfilling the trench with treated
E
material and protecting the trench with a
E
TR
50mm thick concrete cover strip x 300mm
wide measured from the external wall of the
building. 2 durable notices shall be installed S
LL
in prominent locations stating method of
protection, date of installation, life expectancy
I
Site Plan
and scope and duration of future inspections.
Regular inspections of the building are to be
carried out to ensure the barrier has not
H
been bridged by termites. Scale 1 : 200
Inspections are to be carried out as per notices.
MCU - ISSUE B
North Q.B.C.C Licenced Signatory Project Name
N
Builder and trades to confirm all measurements,
details and specifications prior to set out and
Proposed Addition to Unit
ordering of materials. No responsibility will be taken
Sunshine Coast Client & Project Address
by Zest Building Design after construction has
commenced. P | 0457314346 W E R. Beanland & S. Slocombe
A | 30 Wattlebird Drive, Doonan, QLD 4562
These drawings are supplied on the condition that, in E | [email protected] 23 Hill Street, Sunshine Beach QLD 4567
the event of error, this firms' liability is limited only to W | www.zestbuildingdesign.com.au
Designer (s) Drawn by Drawing Title
the cost of amending these drawings. S
ABN: 37 601 151 508 ICB ICB Site Plan
© This information remains the property of Zest Q.B.C.C Lic. No: 1261456
B MCU - Issue B 19/05/15 Building Design Pty Ltd. Authority is granted for once Scale Property Description Project Number Phase Bld # Sheet Number Issue
A Sketch Design A 07/05/15 only use by the client at the site address nominated.
Unauthorised reproduction is prohibited by law.
As indicated Lot 1 / GTP 105789 15018 SD 00 SK.01 B
Issue Description Date
Original sheet size A3 (297x420) Plot date: 19/05/2015 9:50:59 AM
See the original