220200 - 27 Adams Street, SUNSHINE BEACH - Slope Stability Report · EXE22/0017
200 series blockwork with
LINDSAY CONSULTING PTY
LINDSAY CONSULTING PTY LTD
N16 bars @ 400 crs each LTD
way and as shown.
RPEQ 4928
OFF. 2C/82 PARKER STREET, MAROOCHYDORE PH 54 792 118
THIS DRAWING REMAINS THE PROPERTY OF
LINDSAY CONSULTING PTY LTD AND IS FOR
THE SOLE USE OF THE CLIENT. NO PART
MAY BE USED IN PART OR WHOLE WITHOUT
PRIOR EXPRESS WRITTEN CONSENT OF
LINDSAY CONSULTING PTY LTD
1.8 m
Ply braces bolted Lift shaft CLIENT AND PROJECT DESCRIPTION
3.0 m
into suspended by others PAUL CLOUT DESIGN
Blockwork planter box slab over
as per builders specs. PROPOSED RESIDENCE
300 max high.
id NO. 27 ADAMS STREET
vo SUNSHINE BEACH
0.9 m
Refer Detail 3
DRAWING TITLE
STRUCTURAL PLAN
Stair design
by others
360 UB 56.7
290x290 block piers
with 4-N12 bars
id
vo
SCALES
300 series blockwork wall with
Refer Detail 1 Bracing Required 233.0 kN 0 1 2 3 4m
C3 360 UB 56.7 Bracing Provided >>250kN
2-N16 vertical bars @ 400 CRS. Timber pergola by others
N16 horizontals @ 400 CRS. Orig. 1:100
Refer Detail 2 CANTILEVERED VOID STRUCTURE
Exterior steel structure has not been SURVEY DATUM
designed to support any stair loads.
.
C2 ASSOCIATED CONSULTANTS
C1 C1
Bracing Required 128.0 kN
Bracing Provided >>150kN
C1 - 89x89x5 SHS column fixed to slab with 90x90x12mm WIND CLASSIFICATION - N4
baseplate & 1-M16 welded 8.8 grade threaded rod.
STUD HEIGHTS & SIZES
Ramset chemset reo 502. 150mm min. embedment.
C2 - Ø168.3 x 6.4 angled CHS column fixed to slab with 12mm BRACING LEGEND NON LOAD BEARING WALLS
baseplate and 4-M12 chemsets. Ramset chemset reo 502. 150mm INDICATES M12 BOLT STUDS 2700 - 90x35 MGP10 @ 450 CRS
min. embedment.
1.8 m
C3 - 200 UC 52.2 column INDICATES INTERNAL BRACE WALL - 1800mm LENGTH OF STRUCTURAL PLY BRACING WALL (JD5 TIMBER TOP PLATE - 90x35 MGP10
AS PER AS1684.2 SPECIES - 5.2kN/m). 4.0mm F27 EXTERNAL PLY SHEETING FIXED TO ONE SIDE OF STUD WALL, STUDS
TYPE (H) METHOD B BOTTOM PLATE - 90x35 MGP10
TO BE AT 450mm CENTRES MAXIMUM. VERTICALLY INSTALLED SHEETING TO BE NAILED TO TIMBER REVISION LIST
FRAME WITH 30mm x 2.8 CLOUTS OR FLATHEAD NAILS. NAILS ARE TO BE LOCATED AT 50mm
A BUILDER REVIEW - NOT FOR CONSTRUCTION 19/08/22
CENTRES TOP & BOTTOM, 150mm CENTRES ALONG EDGES AND AT 300mm CENTRES ALONG INTERMEDIATE
NOGGINGS - 1350mm CRS MAXIMUM
STUDS. PROVIDE 13kN CAPACITY BOLT WITHIN 50mm OF EACH END OF THE BRACING WALL CONTINUOUS
ALL STUDS NOT NOTCHED
FROM BOTTOM PLATE TO SLAB/FLOOR FRAMING AT 1200mm CENTRES MAXIMUM IN BETWEEN.
ROOF BATTENS
METAL ROOF BATTENS FIXED IN
SUSPENDED SLAB HAS BEEN DESIGNED TO NOT REQUIRE ACCORDANCE WITH MANUFACTURER'S
SPECIFICATIONS
ANY LOAD BEARING LINTELS. THEREFORE, WE HAVE NOT
GROUND FLOOR STRUCTURAL PLAN SPECIFIED ANY LINTEL SIZES. BUILDER SHALL FIX INTO PROTECTIVE COATINGS FOR STEELWORK MUST
BE IN ACCORDANCE WITH THE BCA 3.4.4.4 AND Computer File
SCALE 1:100 SUSPENDED SLAB WITH N12 STARTERS @ 400 CRS. TABLE 3.4.4.2
DRAWING NUMBER
220873FD.DWG
SHEET REV.
22-0873-F16 16 A
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
220200 - 27 Adams Street, SUNSHINE BEACH - Slope Stability Report.pdfRelated documentApplication case desk ↗
About this file
- File size
- 9.6 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.