Log in to see the plans as drawn LEGEND
PROPOSED DRIVEWAY
150 THICK N32 CONCRETE
D D D D D
EXISTING STORMWATER
EXISTING SEWER MAIN
EXISTING WATERMAIN
EXISTING ENERGEX - UNDERGROUND
EXISTING TELSTRA
PROPOSED KERB ADAPTORS
THE COCKLESHELL
AND ROOF WATER CONNECTION
1.50m 1.50m 0.59m
SAW CUT JOINT
(REFER DWG 07 FOR DETAILS)
EXPANSION JOINT
(REFER DWG 07 FOR DETAILS)
4 FSL 2.65 FSL 2.65
1 2 3
SETOUT POINTS
4.00m
12.5% 2.5% 5.0%
4.95m
No, LEVEL *
1 1.566
PROPOSED DRIVEWAYS 5 2 1.753
AS PER IPWEA STD DRG
RS-049 (TYPE 5) & RS-050 7 5.5%
3 1.791
4 1.821
8 5 2.175
6 1.533
1.73m
9 7 1.721
8 1.758
19 FSL 2.30 FSL 2.50
9 1.788
10 1.535
11 1.722
SL 2.40
12 1.760
13 1.790
0.70m
18 14 1.564
5.3% 15 1.751
16 1.789
10 11 17 1.819
18 2.182
19 2.132
4.95m
* REPRESENTS FINISHED CONCRETE LEVEL
4.00m
12.5% 2.5% 5.0%
PROPOSED DRIVEWAYS
AS PER IPWEA STD DRG 125mm THICK N32 CONCRETE
RS-049 (TYPE 5) & RS-050 14 15 FSL 2.65 FSL 2.65 WITH SL72 MESH
16 17
-
NOOSA COUNCIL
NOTES
APPROVED PLAN
MCU17/0563 & OPW17/0597 1. DRIVEWAY AND CROSSOVER TO BE CONSTRUCTED IN
ACCORDANCE WITH IPWEAQ STD DRG RS-049 & RS-050
4 JUN 2018 2. ALL ROOFWATER AND STORMWATER TO DISCHARGE
CAUTION - TO NEW KERB ADAPTORS AND DRIVEWAY STORMWATER PIT
EXISTING SERVICES THE CONTRACTOR IS TO DETERMINE THE EXACT 3. DRIVEWAY SET OUR TO BE INSPECTED BY AN RPEQ
LOCATION OF ALL EXISTING SERVICES IN THE VICINITY OF THE PRIOR TO POUR.
PROPOSED WORKS PRIOR TO THE START OF ANY CONSTRUCTION. NOTE: 4. ALL VERGE AREAS TO TIE BACK INTO EXISTING
THE COST OF ANY RECTIFICATION WORKS DUE TO DAMAGE TO FOR BUILDING SETOUT REFER TO ARCHITECTS DRAWINGS
EXISTING SERVICES SHALL BE BORNE BY THE CONTRACTOR.
360 CIVIL CONSULTING PTY LTD No Date Amendment
Design: J.A.G FOR APPROVAL CLIENT: JOHNSON COLES, JOHNSON, RANDALL & HUSSAIN JOB NUMBER
A 08-03-18 CHANGES AS PER COUNCIL RFI
ABN: 13 609 593 339 Drawn: J.A.G PROJECT: PROPOSED DUPLEX DEVELOPMENT
BEATRICE GIBBERD RPEQ 14557 - DIRECTOR AND PRINCIPAL ENGINEER
2017115
23 OOGAR STREET, MAROOCHYDORE. QLD 4558 Date: 04/11/17
BEATRICE GIBBERD RPEQ 14557 AT: 30-32 COCKLESHELL, NOOSAVILLE
DRAWING No:
Mobile: 0403 862 009 Email: [email protected] Checked: B.G. DATE: 04/11/2017 LOT 11 ON RP138550 & 0 BUP6971
THIS PLAN IS COPY PROTECTED BY 360 CIVIL CONSULTING PTY. LTD.
Datum: A.H.D. Size: A3 TITLE: DRIVEWAY AND STORMWATER SETOUT PLAN
06 of 12