Original source · versioned page text
21.101-013_11 Masthead Quay Jetty_[C1]
SEABED ANCHORS TO BE A FULLY
WELDED ALUMINUM FRAME.
MITRE JOINTS & CFW ALL ROUND.
10 PLATE GUSSET
100 HIGH
CFW TO CHS 250
600
76.2 x 4.75 CHS
ALUMINUM TUBE
(RT7646410)
JETTY FIXING BASE PLATE
REFER TO TYPICAL DETAIL
CUT KICK BOARD SHORT
EITHER SIDE OF JETTY
FIXING CONNECTION
J1
FENDER FIXINGS
TO SUPPLIERS DETAILS
76.2 x 5.0 CHS PILE
FENDER
SEABED
EMBEDMENT
1000
HIGH SET SEABED ANCHOR
TYPICAL ELEVATION
1:10
100
10 ALUMINIUM BASE
PLATE
CFW TO SHS
2-M12 COACH SCREWS
150
FIXED TO J1
38
75 WIDE JOIST BELOW
JETTY FIXING BASE PLATE
TYPICAL PLAN DETAIL
1:10
100mm 0 100 200 300 400
1 :10
CONSTRUCTION ISSUE
© THIS DRAW ING IS ASSOCIATED CONSULTANT: CLIENT: PROJECT: DRAWING TITLE:
Long View
PROTECTED UNDER
COPYRIGHT IN ACCORDANCE
WITH AGREEMENT BETW EEN
LODESTAR MERIDIAN PTY LTD
NOOSA JETTY GRAEME AND SUZANNE PROPOSED NEW JETTY TYPICAL JETTY DETAILS - SHEET 2 21.101-013
T/AS LONG VIEW
CONSULTING ENGINEERS
AND THE CLIENT AS NAMED SERVICES CUTLER L Consulting Engineers Pty Ltd JOB No.
HEREIN. EXCLUSIVE USE IS
GRANTED UNDER THE V Lodestar Meridian Pty Ltd T/as Long View Consulting Engineers
AGREEMENT ONLY FOR THE
PROJECT. THIS DRAWING
Post:
ABN:
PO Box 963 Cooroy QLD 456
87 711 552 832 11 MASTHEAD QUAY DRAWN:
Author
CHECKED: APPROVED:
SAB S111 A
SHALL NOT BE Mobile: 0414 681 676
CONSTRUCTED UNLESS
DESCRIBED AS
A CONSTRUCTION ISSUE 07/04/25 SAB FJM Email: [email protected]
Internet: www.longviewconsulting.com.au
NOOSAVILLE 4566 DESIGNED: CHECKED: RPEQ 19951 DATE: SCALE:
AS NOTED - A1 ORIGINAL SIZE DRAWING No. REVISION.
"CONSTRUCTION ISSUE". REV DESCRIPTION DATE DRAWN APPROVED Designer FJM 07/04/25
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the original