GENERAL NOTES
unit 1 + 2/35 karathina street, noosa heads qld 4567
lot 125 on RP9258
TIMBER FRAMING AND CONSTRUCTION
Areas 1. ALL CONSTRUCTION TO BE IN ACCORDANCE WITH
THE AUSTRALIAN DOMESTIC BUILDING CODE.
2. ALL TIMBER FRAMING TO BE IN ACCORDANCE WITH
Name Area AS 1684.2 2010 RESIDENTIAL TIMBER FRAMING MANUAL.
balcony 2 5.22 m² 3. PINE FRAMING TO BE MINIUMUM STRESS GRADE
balcony 1 5.22 m² MGP 10/MGP12
Grand total 10.43 m² 4.HARDWOOD FRAMING TO BE MINIMUM STRESS
GRADE F14 & MINIMUM JOINT GROUP J2.
5. TIMBER FOR TRUSSES TO BE MINIMUM JOINT GROUP JD4.
06 of 06 6. TRUSSES TO BE FIXED IN ACCORDANCE WITH MANUF.
SPECIFICATIONS ALL OTHER FIXINGS TO BE IN
ACCORDANCE WITH AS 1684.2 2010
Elevation 2 - a 7.LAMINATED BEAM SIZES BASED ON HYNEBEAM SPAN
TABLES WHERE OTHER BRANDS ARE USED, SIZES TO
NOTE: dimensions + existing step down to be BE CONFIRMED WITH MANUFACTURERS SPECIFICATIONS.
3070 confirmed by builder + engineer to confirm structural finish 8. ALL DIMENSIONS TAKE PRECEDENCE OVER SCALES
9. BUILDER AND TRADES ARE TO CONFIRM ALL
04524XOXSW MEASUREMENTS, DETAILSAND SPECIFICATIONS PRIOR TO
90
SETOUT AND ORDERING OF MATERIALS
10. ANY ERRORS ARE TO BE ADDRESSED TO THE DESIGNER
AS NO RESPONSIBILITY WILL BE TAKEN AFTER
existing CONSTRUCTION HAS COMMENCED
line of wall 11. ALL TRADES ARE TO CONFORM WITH THE
bed 2 CURRENT AUSTRALIAN STANDARDS RELATING TO HIS OR
HER OWN WORK
existing screening
bed 1 12. TERMITE PROTECTION TO BE PROVIDED AS PER AS
4790
3660.1.2000
tv room
void
DOMESTIC SMOKE ALARMS
1. ALL BEDROOMS AND HALLWAYS ARE TO BE INSTALLED
WITH PHOTO ELECTRIC SMOKE ALARMS IN ACCORDANCE
WITH BUILDING FIRE SAFETY LEGISLATION AMENDMENT
ens bath REGULATION 2016
2. SMOKE ALARMS MUST BE POSITIONED IN ACCORDANCE
WITH AS 1670.6 - 1997 FIRE DETECTION, WARNING, CONTROL
AND INTERCOM SYSTEMS.
3. DEVICES MUST BE EITHER INTERCONNECTED OR HARD
WIRED (EXISTING DWELLINGS ONLY) THAT CANNOT BE
REMOVED FROM DEVICE
ens bath 4. ALARMS TO BE INSTALLED IN ALL HALLWAYS AND
BEDROOMS TO EXISTING RESIDENCES
S INDICATES THE LOCATION OF WIRED SMOKE ALARMS
GLAZING
study 1. DOOR AND WINDOW SCHEDULE IS INDICATIVE ONLY AND
void SUBJECT TO CONFIRMATION UPON SITE MEASURE
2. OBSCURE WINDOW NOTATION REFERENCE ONLY, CLIENT
existing line of opening TO CONFIRM WITH BUILDER AND WINDOW SUPPLIER FOR
bed 1 PRIVACY OPTIONS
bed 2
art room ELECTRICAL AND ENERGY EFFICIENCY
1620
1. ELECTRICALS TO BE CONFIRMED BY OWNER/BUILDER
AND ELECTRICIAN, PROPOSED PLAN IF REQUESTED
INDICATIVE ONLY
Elevation 4 - a 1160x148OXSW
DOWNPIPES
3070
ALL LOCATED DOWNPIPES INDICATIVE ONLY AND
06 of 06 to frame CONFIRMED AT TIME OF ROOFING CONSTRUCTION
AND COMPLIANCE
proposed floor
NOT FOR CONSTRUCTION
NOTE: INSTALLATION OF ALL EXTERNAL MATERIALS BY BUILDER AS PER MANUFACTURERS SPECIFICATIONS AND CERTIFICATION REQUIREMENTS AS OUTLINED BY NCC
PROPOSED: CLIENT: HELEN MADDERN BUILDER: CHRISTIAN MANDY'S DESIGN + DRAFTING SHEET: 5 of 6 DATE: ISSUE NO:
BALCONY BUILD IN PH: 0419 296 088 PH: 0422 652 760 QBCC NO: PH: 0403 481 474 QBCC: 15117996 SCALE: 1:100 22 JUNE 2026 HM-2026-B
NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION NOTE: BUILDER TO CONFIRM SITING AND DIMENSIONS BEFORE CONSTRUCTION NOTE: THESE DRAWINGS TO BE READ IN CONJUNCTION
WITH ENGINEERS DRAWINGS RESPONSIBILITY LIES THERE WITH WITH ENERGY EFFICIENY REPORT
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix A - Design Plans.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.5 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.