Tods - Engineering Plan · OPW17/0225
Attached to the e-mail IDAS Forms, Report, Engineering Plan, Stowmwater Design OPW17/0225.
Plans and drawings: the text below has words only, no drawings.
SETOUT POINTS SERVICE CAUTION CAUTION DANGER
POINT EASTING NORTHING LEVEL LOCATIONS WATER MAIN TELCO ASSETS OVERHEAD
BEFORE YOU DIG ELECTRIC CABLES
1 1007.037 2991.139 46.201
SAW CUT EXISTING AC 2 1007.029 2994.946 46.307
It is the responsibility of the
Foreman to contact the relevant
service authorities to ascertain
elstra
NEW CONCRETE DRIVEWAY
3 1007.019 2998.968 46.424 the exact location of services energex
GENERALLY IN ACCORDANCE WITH prior to construction.
IPWEAQ STD DRGS RS-049 & RS-050 PAVEMENT REINSTATEMENT. 4 1007.010 3002.883 46.608
01 02
- - REFER TYPICAL SECTION. 5 1007.001 3006.797 46.770
ELANDA STREET
JOIN NEATLY GENERAL NOTES
JOIN NEATLY
DWY CL
TO EXISTING TO EXISTING 1. DO NOT SCALE DRAWINGS.
2. ALL DISCREPANCIES SHALL BE REFERRED TO THE SUPERINTENDENT FOR CLARIFICATION BEFORE PROCEEDING.
01 02 03 04 05 3. THE CONTRACTOR SHALL NOTIFY THE SUPERINTENDENT IN WRITING OF ALL VARIATIONS ARISING FROM THE CLARIFICATION OF THE
DISCREPANCY.
4. THE CONTRACTOR SHALL SUBMIT DETAILS OF ANY ADDITIONAL COST ARISING FROM A VARIATION TO THE SUPERINTENDENT FOR
APPROVAL, BEFORE PROCEEDING WITH THE WORKS.
5. ALL WORK AND MATERIALS SHALL BE IN ACCORDANCE WITH THE DRAWINGS, SPECIFICATIONS, CURRENT RELEVANT AUSTRALIAN
STANDARDS, OTHER STATUTORY REQUIREMENTS AND TO THE SATISFACTION OF THE LOCAL AUTHORITY AND THE ENGINEER.
6. NO WORK IS TO COMMENCE ON SITE UNTIL THE APPROVAL OF THE COUNCIL HAS BEEN RECEIVED IN WRITING AND AN OFFICIAL
4.500
PRE-START MEETING WITH A REPRESENTATIVE OF COUNCIL AND THE ENGINEER HAVE BEEN HELD. THE CONTRACTOR IS TO OBTAIN
NEW 1.2m WIDE CONCRETE PATH. A COPY OF THE MINUTES OF THE PRE-START MEETING AND SHALL COMPLY WITH THE REQUIREMENTS THEREOF.
MATCH EXISTING WIDTH REFER TYPICAL SECTION
7. ALL CONSTRUCTION SHALL COMPLY WITH THE RELEVANT WORK PLACE HEALTH AND SAFETY LEGISLATION.
8. WORKING HOURS, COMMUNICATIONS PROTOCOLS, SITE ACCESS, AREA FOR CONTRACTORS FACILITIES/STORAGE AND SITE
SECURITY TO BE AGREED WITH THE PRINCIPAL AND SUPERINTENDENT.
9. THE CONTRACTOR SHALL PROVIDE ALL MANAGEMENT PLANS, INCLUDING TRAFFIC MANAGEMENT PLAN, ENVIRONMENTAL
MANAGEMENT PLAN AND WORK PLACE HEALTH AND SAFETY PLAN FOR REVIEW AND APPROVAL OF PRINCIPAL AND
SUPERINTENDENT, PRIOR TO CONSTRUCTION.
10. FOLLOWING COMPLETION OF THE WORKS THE CONTRACTOR SHALL CLEAN UP THE SITE AND DEMOBILISE TO THE SATISFACTION OF
THE PRINCIPAL AND SUPERINTENDENT.
RELOCATE WATER METER BOX CLEAR SURVEY
OF NEW DRIVEWAY. APPROVAL TO BE 1. THIS DESIGN IS BASED ON SURVEY PROVIDED BY MARTOO CONSULTING PTY LTD.
SOUGHT FROM UNITYWATER.
2. ALL LEVELS ARE TO AUSTRALIAN HEIGHT DATUM (AHD).
3. THE CONTRACTOR SHALL CONFIRM EXISTING LEVELS, FEATURES AND UTILITIES PRIOR TO CONSTRUCTION.
4. ALL ELEMENTS OF PROPOSED WORK TO BE SETOUT AND CHECKED BY THE CONTRACTOR'S LICENSED SURVEYOR AND ANY
DISCREPANCIES ARE TO BE REPORTED TO THE SUPERINTENDENT.
M1 K&C AS PER NSC STD DRG 9001 1.2m WIDE
0.615 CONC PATH 0.5 1.0 2.3 NOM
EXISTING SERVICES
AS PER
SETOUT POINT
PAVEMENT TO MATCH EXISTING IPWEAQ 1. THE LOCATION OF ALL IN-GROUND AND OVERHEAD SERVICES HAS BEEN DETERMINED FROM FIELD SURVEY, DIAL BEFORE YOU DIG
30mm AC WEARING COURSE (MIN) STD DRG
125mm BASE COURSE (MIN) ENQUIRIES AND INFORMATION PROVIDED BY THE SERVICE PROVIDERS / AUTHORITIES.
RS-065 MIN 75mm
125mm SUB-BASE COURSE (MIN) TOPSOIL & TURF 2. THE SERVICES ARE SHOWN ON THESE DRAWINGS FOR INFORMATION ONLY AND NO RESPONSIBILITY IS TAKEN FOR THE ACCURACY
OR COMPLETENESS OF THE INFORMATION SUPPLIED.
RP BDY
0% 20mm FALL -5%
MATCH EXISTING CROSSFALL vvvvvv v v v v v v vv v1 : 6 3. NOT ALL EXISTING SERVICES HAVE NECESSARILY BEEN IDENTIFIED AND SHOWN ON THE DRAWINGS.
vv v vv vv
GRATED DRAIN vvvv
vv v v 1 : 4 4. THE CONTRACTOR SHALL VERIFY THE LOCATION OF ALL EXISTING SERVICES ON THE SITE PRIOR TO COMMENCING WORKS.
vvvv
NATURAL SURFAC vvvv
E vvvv 5. EXISTING VALVES, HYDRANTS, PITS, ACCESS CHAMBERS AND OTHER UTILITIES SHALL BE MODIFIED WHERE NECESSARY TO SUIT
vvvv
vvvv
vv FINAL FINISHED SURFACE LEVELS.
JOIN TO EXISTING
AS PER IPWEAQ SUBSOIL DRAIN AS PER IPWEAQ STD DRG R140.
STD DRG R170 CONNECT TO EXISTING SUBSOIL IF PRESENT.
SECTION 02 TYPICAL ROAD SECTION
1:50 (A1) 1:100 (A3) -
PROPOSED
DUPLEX
CH 0.000
RL 46.370
CH 0.275
RL 46.340
CH 1.215
RL 46.480
CH 2.415
RL 46.500
RP BDY
CH 5.415
RL 46.049
A
E
R
A
D
E
BUILDING
B
R
U
T
IS
D
FP FRONT
SAW CUT
FP BACK
GALV / STAINLESS STEEL DOWELS
K&C INV
K&C LIP
400 LONG R16 AT 450 CRS
D
IR
3.0m CURVED TRANSITION
EA
E
O
C
NATURAL
F
AR
T
SURFACE
IO
F
1:4
LO
ED
N
OM
CH 14.237
RL 43.839
2.2m MIN
W
B
UR
HEADRO
T PROPOSED
DIS
CH 17.737
RL 43.400
UN POOL
150mm THK 25MPa CONCRETE DRIVEWAY ON
COMPACTED CBR15 GRAVEL BASE (100mm MIN)
WITH KEYED CONTROL JOINTS AT 6m CRS &
GARAGE
REINFORCED WITH SL82 MESH
PROPOSED NEW EASEMENT
INSTALL SEDIMENT FENCE IN ACCORDANCE
J:\2014\14725_Duplex_61_Elanda_Street_Sunshine_Beach\CADD\#ACAD\#CIVIL\14725_CIVIL.dwg
WITH IECA STD DRGS SF-01 & SF-02 CONNECT BUILDING STORMWATER DRAINAGE TO GRATED
1m WIDE x 1m DEEP x 13m LONG INFILTRATION TRENCH. 3.5m CURVED TRANSITION DRAIN
SECTION 01 DRIVEWAY PROFILE
1:50 (A1) 1:100 (A3) -
0 1 2 3 4 5m 0 0.5 1 1.5 2 2.5m
GENERAL ARRANGEMENT
1:100 (A1) 1:200 (A3) 1:50 (A1) 1:100 (A3)
SCALE 1:100 (A1) 1:200 (A3)
COPYRIGHT © Associated Consultants Client Drawn Verified Project Drawing Title Scale Sheet Size
This drawing is subject to PLANNERS & SURVEYOR JF SP
copyright in accordance with the
MARTOO CONSULTING PTY LTD
ZIGANAIRRE PTY LTD Designed Verified
61 ELANDA ST, SUNSHINE BEACH
GENERAL ARRANGEMENT AS SHOWN A1
agreement between Tod
Consulting pty ltd (tc) and tc's
client. This drawing shall only be
(07) 5447 2500 JF SP PROPOSED DUPLEX DEVELOPMENT
AND DETAILS Drawing Number
Approved RPEQ No
used for this specific project. ARCHITECT
S PRYSTUPA 1137 RDP LOT 408 RP48112 14725-C001
This drawing shall not be used BRIGHT BUILDING DESIGN Noosa: 07 5449 9600 LOCAL AUTHORITY NOOSA
B 12.06.17 INFILTRATION TRENCH RELOCATED JF Mark Teunon 0402 750 622 Sunshine Coast: 07 5329 3190 Mackay: 07 4840 2337
Signed MCU APPROVAL HORIZ DATUM LOCAL 0 10 20 30 40 50 60 Sheet Revision
for construction until marked as PO Box 61, Noosaville, QLD 4566
A 18.05.17 PRELIMINARY ISSUE JF ROL APPROVAL VERT DATUM AHD (OPM44260)
'issued for construction' in the
revision description. Rev Date Revision Description Drawn
[email protected] www.todconsulting.com
ABN 39 128 805 336
12.06.17 OPW APPROVAL RL DATUM RL 49.843 MEASUREMENT BAR - INCREMENTS IN mm
1 of 1 B