    PLUMBING ARTICULATION GUIDELINES FOR DESIGN & INSTALLATION
     Notes: The following notes and details are a guide only of articulation for sanitary                                                                Down Pipe                                                                                                             Down Pipe                                                                             Down Pipe
     plumbing, drainage and should be read in conjunction with AS/NZ3500, AS2870 and any                                                                                       Allow visual Space to                                                                                                 Allow visual Space to                                                                       Allow visual Space to
     other relevant coades and standard.                                                                                                                                       comply with AS 3660.1                                                                                                 comply with AS 3660.1                             Downpipe adapter fixed                    comply with AS 3660.1
                                                                                                                                                                                                                                                                                                                                                       to downpipe & glued to
    1. All drains installed in ground that is filled, unstable, contain expansive clays                                                   Flexible Joint Between                                                                                           Overlap Pipes 150mm                                                                               Expansion Joint
    (E.G "M, H E and P Class Sites) or water charged and where soil movement may                                                          slab and wall
    effect the performance of any drain, a Plan and Specification together with a Soil                                                                                                                                                                                                                                                                      Concrete Path or
    Report and Calculations showing methods to protect the drainage shall be lodged                                                                 Grated Drain                                                                                                           150 Min.
                                                                                                                                                                                                                                                                                                                                                       Surface Fall 1 : 50 Min
     with the relevant local authority including the requirements of the compliance permit and                                                                                                                                                                        N.S.L
    assessment.
    2. All sewer and stormwater to be constructed in accordance with AS/NZS 3500 and the
    requirements of AS2870, Section 5, Clause 5.2, 5.6 and Section 6.6, Clause 6.6. Articulation
    and expansion joints are to be provided to accommodate movement in all pipe work within 1
    metres of the dwelling. and comply with AS 1260.
    3. Plumbing and Drainage under the slab should be avoided where practical (Refer:                                                     Selected Artificial/                                                                                              Selected Artificial/
     AS/NZS 3500 Clause 4.10).                                                                                                            Flexible Joint                                                                                                    Flexible Joint
                                                                                                                                                                                                                                                                                                                                                  Selected Artificial/
    4. Grades in Pipework on "M, H and P" Class Sites shall have a minimum grade of 1 : 50                                                                                                                                                                                                                                                            Flexible Joint
     within 1.5m of the BLDG and 1 : 60 elsewhere. Grades in flexible fittings to be set at the                                     Inground Pipe Work                                                                                               Stormwater Drainage Pipe
    minimum grade.
     5. All expansion and articulation joints to be installed in accordance with manufacturer's
     recommendations. All joints to be set mid point so as to allow for maximum in either direction.                                                                      Allow Pipe work to move vertically                                                                                                                                                                             NOT RECOMMENDED FOR "P" SITES
                                                                                                                                                                          & independent of BLDG Footings                                                                                                                                                 Stormwater Drainage Pipe
     6. Stormplastics (SA) PTY LTD; "Swivel Joints" shall not be used as a bend to achieve
     correct fall, the joint shall be set in a straight line of the drain to allow maximum (+) or (-)                                                       DOWN PIPE TO GRATED DRAIN DETAIL                                                                             STORMWATER DETAIL (ALT.)                                                                                 STORM WATER DETAIL H SOIL CLASS
     movement. A minimum 15 Deg. Bend to be installed efore swivel joints to achive minimum
     grades from the face of the footing.                                                                                                                                              NOT TO SCALE                                                                                          NOT TO SCALE                                                                                                 NOT TO SCALE
     7. Details and support of traps at the O.R.G to be CONSIDEREDed on site to allow for
     potential movement including isolated and articulationassociated with the concrete paths                                                                                                                                                                                                                                                                                                      Sealable Cap/Shroud
     and pavements The O.R.G shall be castin concrete monolithically with the footing system                                                                                                                                                                                                                                                                                                       or Epoxy Sealant; incl.
     on Class "H and E" Sites.                                                                                                                                                                                                                                                                                                                                                                    Vermine/Termite Barrier                     Timber Floor
     8. All PVC Pipe work passing through concrete must have 25mm minimum of approved
     Lagging. The use of corrogated flexible P.V.C pipe product is not permitted.                                                   I.O
     9. Storwater systems that collect roof water and surface water are required to be designed                                                                                                                                                                                   Min. 15 Deg Bend Typical
     and constructed in accordance with AS/NZS 3500, Part 5.
     10. The use corrugated flexible PVC Pipe products shall be avoided on Class "H and E"                                                                                   15 Deg. Bend                                                            Selected Artificial Joint E.G Storm Plastics
     Sites as they are not able to expand longitudinally to accommodate potential vertical and                                                      45 Deg. Bend                                                                                     Swivel Joint or other approved flexible joint                                                                                                  Selected Artificial/
     lateral movement at the slab or footing edge unless specifically detailed by the                                                                                                                                                                installed to manufacturer's recommendations                                                                                                    Flexible Joint
     manufacturer.
     11. All joints in stormwater pipes within 3 metres of the BLDG. under construction shall be
     articulated to accommodate ground movement without leakage.                                                                                                                                                                                                                                                                                      Lagging thickness 25 & 40mm
                                                                                                                                                                                                                                         Lagging thickness 25 & 40mm                                                                                  on "E" Class sites U.N.O
     12. Septic tanks and associated soakage trench or evapotranspiration areas shall be located                                                                           1.0m Max
                                                                                                                                                                                                                                         on "E" Class sites U.N.O
     within the allotment such as to prevent soil moisture ingress to the AWNING EXT. foundation
     that may increase the soil moisture content. Joints in plumbing pipes within 3 metres of the                                                  Selected Artificial/
     AWNING EXT. under construction shall be articulated to accommodate ground movement                                                            Flexible Joint
     without leakage. Septic tanks in particulare require specific & careful detailing.
                                                                                                                                                                                      Selected Artificial Joint E.G Storm Plastics                                                                                                                                                                       Sewer Pipe
                                                                                                                                                  Sewer Main                          Swivel Joint or other approved flexible joint                                                         Expanda Joint Lubricated wrapped
     13. All pipe work including stormwater fitting and adapters shall be protected from                                                                                              installed to manufacturer's recommendations
     mechanical damage.                                                                                                                                                                                                                                                                     in 2 layers of 1200 micron polyethylene
                                                                                                                                                                                                                                                                                            and sealed with pressure sensitive
     14. Termite protection is not shown on these drawings.                                                                                            TYP. SEWER PIPE THROUGH FOOTING DETAIL                                                                                               tape to exclude soil particles.
     15. All details provided on Drawings are indicative only. Details of pipe penetrations to
                                                                                                                                                                                          NOT TO SCALE                                                                                                                                                                       SEWER PIPE & TIMBER FLOOR DETAIL
     BLDG. foundations are provided on Structural Drawings. If in the advent no Pipe
     penetration details are provided or apparent the Builder/Plumber shall contact the
                                                                                                                                                                                                                                                                                           SEWER PIPE THROUGH FOOTING DETAIL                                                                                 NOT TO SCALE
     Engineer and seek clarification, prior to proceeding with the Plumbing installtion works.                                                     Details & special requirements for                                                                                                                                        NOT TO SCALE   Lagging or Sleeve            Location of Penetration to Engineer's Design
     16. Storm water systems that collect roof water and surface water are required to be                                                          support and/or provisions of articulation
     designed and constructed in accordance with AS/NZS 3500.5-2014 Part 5                                                                         in pipe work for all under slab drainage
     17. The use corrugated flexible PVC pipe products should be avoided on Class H & E                                                            is only required where specified by                                                                                                                                                                                           Selected Artificial Joint E.G Storm Plastics
     sites as they are not able to expand longitudinally to accommodate potential vertical and                                                     the Design Engineer for the relevant                                                                                                                                                                                          Swivel Joint or other approved flexible joint
     lateral movement at the slab or footing edge unless specifically detailed by the manufacturer.                                                                                                                                                                                                                                                                              installed to manufacturer's recommendations
                                                                                                                                                   site classification and/or as required
     18. All details are indicative only, design of path footings etc. and the location of penetrations                                            by: AS 3500 or AS 2870.
     to be designed and specified by an Engineer.                                                                                                                                                                                                            Expanda Bend or approved
     19. Provisions should be made for the connection of overflow or water discharge from fixtures,                                                Expanda Joint Lubricated wrapped                                                                          Expansion Joint on "E" or "P"
     such as: Hot Water Systems (HWS) and A.C to a drain as required by the relevant authorities.                                                  in 2 layers of 1200 micron polyethylene                                                                   Class Sites
    20. Penetrations of concrete edge beams of raft slabs and perimeter strip footings shall be                                                    and sealed with pressure sensitive
    avoided where practicable, but where necessary shall be lagged with closed cell polyethylene                                                   tape to exclude soil particles.
    lagging (thickness as per table) to allow for movement. An approved Sleeve system allowing
    equivalent movement may be used as an alternative to lagging.
    21. Expected minimum requirements for expansion joints and allowable relation in fittings                                                                                                                                                                                                                                                                                                                   Expanda Joint Lubricated wrapped
    as follows:                                                                                                                                                                                                                                     SITE SOIL CLASSIFICATION - "M"                                                                               Sewer Main or                                  in 2 layers of 1200 micron polyethylene
                                                                                                                                                                               Selected Artificial Joint E.G Storm Plastics                         REF: BLACKALL RANGE CONSULTING ENG - SITE CLASSIFICATION REPORT                                              Branch Line                                    and sealed with pressure sensitive
     SITE CLASS              MINIMUM REQ'D EXPANSION JOINT                                 ALLOWABLE ROTATION
                                                                                                                                                                               Swivel Joint or other approved flexible joint                        JOB No: 2024-1006-47 Don Napier Rd-SR-Rev 0; Nov 2024                                                                                                       tape to exclude soil particles.
           E                               150mm                                                 15 Deg.
                                                                                                                                                                               installed to manufacturer's recommendations
           H
              P
                                           70mm
                                   70mm plus additional requirements
                                                                                                 15 Deg.
                                                                                                 15 Deg.
                                                                                                                                                                                                                                                                                                                                                         CONNECTION FROM PIPE WORK TO BRANCH LINE
                                   in the case of fill (min. dependent on                                                                            SEWER PIPE UNDER SLAB-EDGE BEAM/WAFFLE POD DETAIL                                                                                                                                                                                   NOT TO SCALE
                                   Site conditions)                                                                                                                                                                  NOT TO SCALE                                                                                                                      Copyright: The drawing and engineering content shown in this drawing remains the property of Blackall Range
              M                    Minimum 25 mm Lagging to Footings                              N/A                                                                                                                                                                                                                                                  Consulting Engineer and may not be copied, altered, sections omitted or erased and changes made without the prior
                                                                                                                                                                                                                                                                                                                                                       written approval of Blackall Range Consulting Engineer. Acceptance of Blackall Range Consulting Engineer fee proposal
                                                                                                                                                                                                                                                                                                                                                       or estimate is deemed sufficient to effectuate an agreement. Non-payment of said fee proposal or estimate and
                                                                                                                                                                                                                                                                                                                                                       subsequent use of Blackall Range Consulting Engineer drawings or material is a breach of said agreement and subject
                                                                                                                                                                                                                                                                                                                                                       to litigation. ABN 94950162458
Rev. No. Drawn Amendment Details
   0
                                                                                                           Drawn
                                                                                                           CJF
                                                                                                                   Checked
                                                                                                                   CJF
                                                                                                                             Date
                                                                                                                                      Site Classification:                 M                 Blackall Range                                           Email: [email protected]
                                                                                                                                                                                                                                                      PO Box 342, MAPLETON, QLD
                                                                                                                                                                                                                                                      Phone: 54457353                 CLIENT:                                                           PROJECT DETAILS:                                                     Sheet No.                   17 of 21
                                                                                                                                                                                                                                                      Mobile: 0419140465
                                                                                                                                                                                                                                                                                                                                                                                                                             Date Issued:     Nov 2024
                                                                                                                                      Soil Classification:                 CI                Consulting Civil, Structural & Geotechnical Engineer
                                                                                                                                                                                                                                                                                      TONY MORRISSEY                                                    PROPOSED SHED                                                        CAD File:

Copyright: The design and engineering content shown on this drawing remains the property
                                                                                                                                      Wind Category:                       N3                                                             Campbell J Foster                                                                                             695 COLES CREEK ROAD                                                 DRAWING NUMBER                        REV.
of Blackall Range Consulting Engineer and may not be copied, altered, sections omitted
or erased and changed in any way without the prior written approval from Blackall
Range Consulting Engineer. ABN 94950162458
                                                                                                                                      Terrain Category:                    2.5                                             MEIAust (CPEng Civil), RPEQ 7228, NER
                                                                                                                                                                                                                                                                                                                                                        COORAN                                                               2024-1079-S17                          1
Log in to download the original file

Appendix A - Proposal Plans.pdf · 5.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.