Council archive · source document
App E - Noosa Code Address · MCU25/0118
Sustainable Building Design Code
Performance outcomes Acceptable outcomes Applicant Response
Building Design AO8.1 Complies.
Development provides a detailed assessment
PO8 The design achieves compliance by way of the following:
including supporting documents, demonstrating the
Development -
means by which the design meets PO8. • the design adopts a northsouth orientation;
(a) orientates buildings and windows to make
• shade devices are incorporated into the design
the most of prevailing winds, natural AO8.2 to ameliorate sun exposure from the east and
ventilation and cross breezes; Development demonstrates a measured equivalent to west;
(b) maximises shade to east and west walls; a 5star Green Star rating. • the design of each dwelling is emphasized by
(c) contains an open and permeable built form that the indoor / outdoor permeability and
connects indoor and outdoor spaces in an Editor’s note—The publications QDesign and connectivity;
integrated design; QCompanion, prepared by the State of Queensland, • a selection of native species is proposed to
provide climate responsive design principles for create a lush subtropical environment for future
(d) retains existing vegetation and natural
development in south east Queensland. residents;
shading where possible;
Council encourages building and landscape designers • incorporates extensive windows and openings to
(e) incorporates passive building design to reduce to incorporate best practice outcomes described in allow breezes to permeate through living areas
the need for auxiliary heating and cooling; these publications to help development comply with to reduce the reliance on artificial forms of
uses low toxic internal and external building PO8. cooling;
(f)
materials; • provides a minimum floor to ceiling height of
(g) uses natural light rather than artificial light, and 2.7 metres.
may include skylights, atriums and light wells;
(h) contains a minimum of two openings per
habitable room;
(i) provides a minimum floor to ceiling height of
2.7 metres; and
(j) enables efficient operation and use of the
building.
Editor's Note: Refer to Figure 9.4.6.4.
Noosa Plan 2020 – Amendment 1 – September 2020
See the original