Skip to the record
Accept no imitations.

Council archive · source document

08/0831 - Response to Information Request [As Published] · 142008.831

of 43

Text shows just the words. Original shows the document exactly as it was published.

                                                               BARLOWGREGG
                                                                 Aj4r>PA-"
                                                                 Consulting Engineers


Reply to    Sunshine Coast Office                                                          30 July 2008
Enquires    Mr J McDonald
Our Ref:    BM003087/JM5588K
Your Ref

            Sunshine Coast Regional Council
            PO Box 141
            TEWANTIN QLD 4565

            ATTENTION: TRACY ARTHUR


            Dear Tracy

            RE:    APPLICATION NUMBER 2008/831 FOR PROJECT AT 247. 249 AND 253
                   DAVID LOW WAY PEREGIAN BEACH

            We write to you in response to the request for information dated 22 July 2008.

                    Item 1 Please find enclosed 3 sets of our amened civil and structural engineering
                           drawings signed by an RPEQ.

                    Item 3 Please refer to Barlow Gregg VDM structural drawings BM003087/B-01-P
                           and BM003087/B-04-C for construction details of the median kerb on the
                           basement ramp

                    Item 4 We confirm that pit "EX/1" is an existing gully pit Drawing number
                          M3087/C05-E has been amended to reflect this            Drawing number
                          M3087/C06-C shows existing stormwater lines at the outlet of the system.

                    Item 5 Drawing number M3087/C06-C shows the location of the existing sewer
                           line in relation to the proposed stormwater works.

                    Item 6 Stormwater pit "3/2" is located some 13 metres from the nearest opening to
                           the basement. In the event that this pit overflows excess water will fall
                           toward the street frontage rather than in the direction of the basement
                           opening.

            We trust the above is satisfactory.

            Yours faithfully




            PETER BARLOW
            for and on behalf of
            BARLOW GREGG VDM PTY LTD


            Eric

                           Barlow Gregg VDM Pty Ltd ABN 77 1 14 957 363 ACN 1 14 957 363
                            Level 1, 181 Brisbane Road, PO Box 200 Mooloolaba QLD 4557
      P +61 7 5444 0400 F +61 7 5444 0536 E barlowgregg@vdmgroup corn au W www barlowgreggvdm corn au   -Aff -MW
                                                                                                         co
                                                                                                            member
                     FRASER COAST                 SUNSHINE COAST             CORAL COAST

Used in these records

About this file

File size
5.0 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0831 - Response to Information Request [As Published].pdf · 5.0 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.