Skip to the record
Beware of cheap imitations.

Original source · versioned page text

Planning Report

of 26

Page text shows just the words. Original shows the document exactly as it was published.

                                       AO13.2    Vehicular access avoids            The proposed driveway is
                                                 disturbance to the tree            located within an existing
                                                                                    clearing and avoids any
                                                 protection zone of trees on
                                                                                    disturbance to vegetation.
                                                 public land.
PO14   Driveways and crossovers      AO14.1 Only one driveway and          Only one driveway is proposed
       are located so they do not           crossover is provided.         for the dwelling.
       impede the safe and efficient
       use of the road network.
                                     AO14.2 Where the premises has         N/A
                                            frontage to more than one
                                            formed and sealed road and the
                                            roads have differing orders in
                                            the Road Hierarchy, the
                                            driveway and cross­over is
                                            provided on the frontage with
                                            the lower order.


                                        AO14.3 For corner lots, driveways           N/A
                                               and crossovers are located
                                               in accordance with Council’s
                                               standard drawings.


                                        AO14.4   If in the Rural zone or Rural      The driveway crossover will be
                                                 Residential zone, the driveway     constructed to provide a
                                                 and cross­over is located to       minimum safe sight distance in
                                                 provide minimum safe sight         accordance with Austroads.
                                                 distances in accordance with       Crossover is to an existing
                                                                                    access easement that services
                                                 Austroads.                         3 allotments.
PO15   Bushfire hazard                  AO15     Within a bushfire hazard area      The proposed dwelling will be
       management:                               where there is no reticulated      connected to a 5,000 litre
                                                                                    rainwater tank for fire fighting
                                                 water supply, the premises
                                                                                    purposes. The 5,000L tank will
       Where located in a Bushfire               has:                               be fitted with a 50mm camlock
       Hazard Area as shown on                   (a)   an accessible dam,           fitting and a standard fire
       the Bushfire Hazard Overlay                     swimming pool or water       brigade fitting to ensure to tank
       Map in Schedule 2 and not in                                                 is in operational order.
                                                       tank      available    for
       a water service area, an
       adequate, reliable, safely                      firefighting     purposes
       located and freely accessible                   with an onsite water
       water supply is provided for                    volume of not less than
       fire fighting purposes, which                   5,000 litres; and
       is in addition to day to day
       water supply.                             (b)   a water supply outlet
                                                       pipe 50 millimetres in
                                                       diameter and fitted
                                                       with a standard fire
                                                       brigade fitting
                                                       connected to the
                                                       water supply (other
                                                       than where the water
                                                       supply is in a
                                                       swimming pool or
                                                       dam).
PO16   Flood hazards:                   AO16.1   Where the development is      N/A
                                                 located in the Flood Hazard
       Development is designed                   Area as shown on Flood Hazard
       and sited to ensure risk to               Overlay Map in Schedule 2,
       people and property from                  the finished floor level of
       flooding is avoided or                    habitable rooms is at least
       minimised.
                                                                                                      23 | P a g e
Log in to download the original file

Planning Report.pdf · 623 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.