Att 1 Revised Plans
Original PDF page 9, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawn LEGEND.
Mark Description
CO Concrete - Polished
P1 100 SHS Post to Engineer's spec.
P2 150 SHS Post to Engineer's spec.
SK Stainless Steel Sink
TS Toilet Suite
VB Vanity Basin
5780
2 1
WD.4.01 WD.4.02
P1 P1
7580
1460 6120 190
3000
EXTERNAL SLAB TO
39º
ENGINEERS DETAIL
FALL SLAB
600
39.0° SLIDING GLASS DOOR REBATE SLIDING GLASS DOOR REBATE TO BE CONFIRMED
STEP
STEP
SK SK
TO BE CONFIRMED
1800
39º
STEP
WM
WM
VB
LINE OF 190 BLOCK RETAINING UNDER ( SHOWN DASHED)
VB
TS TS
RL. 36.55 m RL. 36.55 m
6860
CORE FILLED 190 CONCRETE BLOCK
CO CO
CONTINUATION OF BLOCKWORK
TO ENGINEERS SPEC + DESIGN
7460
7460
8960
RETAINING WALL UNDER
60/60/60 PARTY WALL,
REINFORCED CONCRETE SLAB & FOOTINGS REINFORCED CONCRETE SUSPENDED SLAB
SLIDING GLASS DOOR REBATE
WITH VAPOUR BARRIER ON 50mm MIN THICK TO ENGINEER'S DESIGN
TO BE CONFIRMED
BEDDING SAND TO ENGINEER'S DESIGN
5660
6565
FALL SLAB
UNIT 1 UNIT 2
P2 DOOR REBATE DOOR REBATE
NOTES:
STEP
STEP
TO BE CONFIRMED TO BE CONFIRMED
STEP
SK FALL SLAB FALL SLAB SK
STEP
P2 EXTERNAL SLAB TO 1). VERIFY ALL DIMENSIONS PRIOR TO
1500
ENGINEERS DETAIL
FALL SLAB
EXTERNAL SLAB TO
EXTERNAL SUSPENDED CO FALL SLAB COMMENCEMENT
900
900
900
SLAB TO EXTERNAL SUSPENDED CONCRETE SLAB
ENGINEERS DETAIL
ENGINEERS DETAIL TO ENGINEER'S DESIGN
2). ALL SLAB PLAN DIMENSIONS ARE TO
OUTSIDE OF WALL UNLESS OTHERWISE NOTED
BLADE WALL
1285 3). FOOTINGS AND SLAB CONSTRUCTION TO BE
IN ACCORDANCE WITH GEOTECHNICAL
6605 2
LINE OF 190 BLOCK RETAINING
1 REPORT AND ENGINEERS DESIGN FOR THIS
UNDER ( SHOWN DASHED)
N
WD.4.01 WD.4.02 ALLOTMENT
12005 4). TERMITE PROTECTION TO BE PROVIDED IN
ACCORDANCE WITH AS 3660.1
BLADE WALL BLADE WALL BLADE WALL 5). ALL SILL REBATES TO BE CONFIRMED WITH
5400 180 2000 2000 180 5920 0 ACTUAL WINDOW/DOOR SYSTEM, REFER TO
MANUFACTURERS DETAILS
Ground Floor Slab Plan 7580 8280 6). PLUMBING PENETRATIONS TO BE
1 1 : 100
CONFIRMED WITH ACTUAL FIXTURE
0 1 2 3 4 5m
SELECTIONS
21/12/2021 11:16:25 PM
For engineering information, Engineer's drawings and information shall take precedence over architectural drawings. 164 Edwards Street, Date: Rev: Issue: Scale: Title: Date:
Client Project
The Building Designer's drawings and recommendations shall take precedence over architectural drawings. The
Amendments
06.08.2021 A Working Drawings 1 : 100 Slab Plan 21.12.2021
Sunshine Beach
Job Details
author is to be notified immediately, should any errors, discrepancies, or conflict become apparent and prior to
Copyright
21.12.2021 C Revised Working Drawings in Response to RFI
proceeding with the works. MCU21/0192
Copyright: The design content shown on this drawing remains the property of Garland Design and is provided only
for the use described. This drawing may not be copied, altered, have sections omitted, erased or changed in any Des: JC Project #: Drawing #: Issue:
way without the prior written approval of Garland Design. Adam Flanagan & Shane Tye Check:JC 21.107 WD.2.05 C