Original source · versioned page text
Att 1 Revised Plans
Original PDF page 14, section 1. The text section number identifies this passage in the reader.
This document appears to be plans or drawings. Its page text below holds only the words printed on the drawings, without the drawings themselves, so it may be jumbled or hard to follow. To see the plans as drawn, choose Original above or download the file (both need you to log in).
Log in to see the plans as drawnWINDOW / DOOR IDENTIFICATION
AW - AWNING WINDOW
C/S - CAVITY SLIDING DOOR
FG - FIXED GLASS
GSD - GLASS SLIDING DOOR
GSSD - GLASS SLIDING DOOR (STACKER) RAFTERS AT 900 CRS TO ENGINEER'S DESIGN.
H - HINGE DOOR RS1 - ROOF SHEETING ROOF BRACING TO ROOF MANUFACTURER'S &
LV - LOUVRE SPANDEK COLORBOND ROOF SHEETING AT 3° ENGINEER'S DESIGN. PITCH AS NOTED.
O = FIXED, X = SLIDING AS VIEWED FROM EXTERIOR) INSTALL TO MANUFACTURER'S SPEC.
EG - EAVES GUTTER ROOF POSTS, BEAMS & ROOF SARKING / INSULATION INSTALLED TO SATISFY
NOTE: 150 HALF ROUND CONCEALED BRACKETS EXTENDA BRACKET TO PART 3.12 OF THE CURRENT NCC VOL. 2
PROVIDE WEATHERSEALS TO EXTERNAL DOORS INSTALL TO MANUFACTURER'S SPEC. 3° ENGINEER'S SPEC. RL. 43.09 m FOR ALL ROOF AND WALL CONSTRUCTION
REFER TO WINDOW AND DOOR SCHEDULE FOR HEAD HEIGHTS RS1 8m ENVELOPE ABOVE NGL
3° (SHOWN RED DASHED)
EG
RS1
EC3
EC3
600 O'H EG
L1 FCL
P1 EC3 PL PL PL (EC3) EXTERNAL CLADDING 3
42350
CEDAR BOARDS (WIDTH TBA) TO SOFFITS
(EC3) EXTERNAL CLADDING 3
3200 PITCHING POINT
RAKED PLASTERBOARD CEILING
CEDAR BOARDS (WIDTH TBA) TO SOFFITS EC1 W213 (TF) TIMBER FLOORING
1806LV SELECT GRADE TIMBER FLOOR BOARDS
D212 (TYPE AND FINISH TO BE DETERMINED
HWD TIMBER DECKING TO 720 C/S
BY CLIENT AND BUILDER )
DECK STRUCTURAL FRAMING D205 FIXED TO YELLOW TONGUE OR SIM. TO
2700
TO ENGINEER'S DETAIL 2424 GSD
MANUF/SUPPLIER SPECIFICATIONS.
BALCONY MASTER BEDROOM WIR BEDROOM 2
EC1
TIMBER FRAMING, ALL FRAME SIZING,
(BA2) BALUSTRADE 2 BRACING & TIEDOWN TO ENGINEERS
1000 min.
FRAMELESS GLASS REBATE GLASS SLIDING DOOR (TYP) EC1 DESIGN & DETAIL
EXTERNAL BALUSTRADE FOR FLUSH FINISH WITH FLOOR REFER
MANUFACTURERS SPECIFICATION + DETAIL
Level 1 TF TF
39650 * FLOOR CAVITY THICKNESS TBC (EC2) EXTERNAL CLADDING 2
*
WITH ENGINEER'S STRUCTURAL DESIGN NRG (OR SIM.) FOAM CLADDING
EC3 PAINT FINISH: WHITE
GL FCL PL 1100 PLASTERBOARD CEILING
P1 - 100 SHS P1 TIMBER FLOOR / DECK FRAMING TO ENGINEER'S DETAIL. 2700 HIGH
TO ENGINEER'S DETAIL JOISTS, BEARERS, TIMBER FRAMING SIZES, ISLAND BENCH (EC3) EXTERNAL CLADDING 3
39250 CEDAR BOARDS (WIDTH TBA) TO SOFFITS
SPACINGS AND FIXINGS TO ENGINEER'S DESIGN.
W205 W204 W203
EC1 2111 FG 2106 LV 2106 LV EC1 (EC1) - EXTERNAL CLADDING 1
REBATE GLASS SLIDING DOOR (TYP) HARDIES SCYON 180 LINEA WEATHERBOARD
FOR FLUSH FINISH WITH FLOOR REFER LOUNGE KITCHEN / DINING
2700
MANUFACTURERS SPECIFICATION + DETAIL NOTE: ISLAND BENCH W202
D202 300mm OVERHANG TO ALL SIDES 0624 FG
2145 GSSD
REINFORCED CONCRETE
SLAB AND FOOTINGS O'HANG 300 (CO) CONCRETE POLISHED
(CO) CONCRETE POLISHED 300 O'HANG POLISHED CONCRETE
TO ENGINEER'S DETAIL POLISHED CONCRETE FLOOR TO GROUND FLOOR
(FINISH TO BE DETERMINED BY CLIENT AND BUILDER ) (FINISH TO BE DETERMINED
Ground Level CO BY CLIENT AND BUILDER )
CO
TO ALLEVIATE STRIKER
250
36550
(EC4) EXTERNAL CLADDING 4
EC4 EC4
190 CONCRETE BLOCK
w/ CONCRETE LOOK RENDER
NATURAL GROUND LINE
SUSPENDED CONC. SLAB TO ENGINEER'S DETAIL AND SPECIFICATION
2300 MIN
2650
2400
BAR REQUIREMENT
190 CORE FILLED CONCRETE BLOCK RETAINING WALLS
TO ENGINEER'S DETAIL.
WATERPROOFING TO BUILDER'S SPECIFICATIONS
Garage Level
33900
DRAINAGE TYPE AND EXTENT TO BE CONFIRMED ON SITE BY BUILDER BASE
Section 2 3050 B99 VEHICLE WHEEL
1 1 : 50
TERMITE TREATMENT TO BE IN ACCORDANCE WITH ONE OR MORE REINFORCED CONCRETE SLAB, SLAB THICKENINGS, FOOTINGS TO ENGINEER'S DETAIL GRATED VEHICULAR DRAIN
METHODS AS SPECIFIED IN AS 3650.1 AND NCC PART 3.1.3
21/12/2021 11:16:32 PM
For engineering information, Engineer's drawings and information shall take precedence over architectural drawings. 164 Edwards Street, Date: Rev: Issue: Scale: Title: Date:
Client Project
The Building Designer's drawings and recommendations shall take precedence over architectural drawings. The
Amendments
06.08.2021 A Working Drawings 1 : 50 Sections 21.12.2021
Sunshine Beach
Job Details
author is to be notified immediately, should any errors, discrepancies, or conflict become apparent and prior to
Copyright
05.10.2021 B Outdoor Area Roof & Landscape Plan
proceeding with the works.
Copyright: The design content shown on this drawing remains the property of Garland Design and is provided only 21.12.2021 C Revised Working Drawings in Response to RFI
MCU21/0192 Des: JC Project #: Drawing #: Issue:
for the use described. This drawing may not be copied, altered, have sections omitted, erased or changed in any
way without the prior written approval of Garland Design. Adam Flanagan & Shane Tye Check:JC 21.107 WD.4.02 C
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.