Log in to see the plans as drawnGENERAL NOTES
To be read in conjunction with all drawings; refer to GLAZING SMOKE ALARMS DRAWING LIST
consultants drawings and specifications for co-ordination of All glazing to be designed and installed in accordance with All smoke alarms to be installed in accordance with AS3786.
services and extent of works. AS2047 and AS1288. Manufacturer to provide certification Smoke alarms in the dwelling must: SHEET NAME SHEET NUMBER ISSUE DATE REVISION
on completion. 1. Be photoelectric (AS3786-2014); and
STRUCTURAL DETAILS 2. Not also contain an ionisation sensor; and Cover WD.1.01 21.12.2021 C
Refer to Consulting Engineer's drawings for all structural WATER CLOSETS 3. Be hardwired to the mains power supply with a secondary General Notes WD.1.02 21.12.2021 C
details. The doors to sanitary compartments must be readily power source (i.e. battery); and
removable from outside the compartment. 4. Be interconnected with every other smoke alarm in the Site Plan WD.2.01 21.12.2021 C
DIMENSIONS dwelling Understorey Park WD.2.02 21.12.2021 C
Do not scale from drawings. Given dimensions are to have WC's to have a minimum clearance of 900mm.
priority over scaled dimensions. Smoke alarms must be installed on each storey: GF Overall Plan WD.2.03.1 21.12.2021 C
All toilet systems to be dual flush. 1. In each bedroom; and GF Dimension Plan WD.2.03.2 21.12.2021 C
CONSTRUCTION 2. In hallways which connect bedrooms and the rest of the
All design, construction and materials to be in accordance SHOWERS dwelling; or Level 1 Plan WD.2.04 21.12.2021 C
with: AAA shower roses to be supplied in accordance with QDC. 3. If there is no hallway, between the bedroom and other Slab Plan WD.2.05 21.12.2021 C
Australian Standards; parts of the storey; and
National Construction Code (NCC); WET AREAS 4. If there are no bedrooms on a storey at least one smoke Roof Plan WD.2.06 21.12.2021 C
Queensland Development Code (QDC); Wet areas are to be waterproofed in accordance with alarm must be installed in the most likely path of travel to exit Landscaping Plan WD.2.07 21.12.2021 C
Building Regulations; AS3740 and the requirements of the NCC. Floor tiles and the dwelling.
Manufacturers specifications and installation details for floor waste to all wet areas. Floors to fall to floor waste at a Elevations WD.3.01 21.12.2021 C
materials used. grade of 1 in 60. All timber walls to wet areas to be lined with Prescribed locations for installing smoke alarms, where Elevations WD.3.02 21.12.2021 C
a waterproof cladding. practicable, must be placed on the ceiling. Smoke alarms
SETOUT must not be placed: Sections WD.4.01 21.12.2021 C
Contractor/builder to confirm all dimensions, levels, BRACING AND TIE DOWNS 1. Within 300mm of a corner of a ceiling and a wall; Sections WD.4.02 21.12.2021 C
boundary lines and pegs on site prior to commencement of Provide bracing and tie down to timber framing in 2. Within 300mm of a light fitting;
any work. accordance with AS1170.2 and the Engineer's drawings. 3. Within 400mm of an air conditioning vent;
Details WD.5.01 21.12.2021 C
4. Within 400mm of the blades of a ceiling fan. Schedules WD.6.01 21.12.2021 C
Should site conditions differ from those indicated seek STORM WATER DRAINAGE
instructions from the Designer. Storm water drainage management system to be in There are special requirements for stairways, sloping ceilings
3D Perspectives WD.7.01 21.12.2021 C
accordance with AS/NZS 3500.3.2. Surface drainage to and ceilings with exposed beams. Specific requirements will Visualisations WD.7.02 21.12.2021 C
DRAINAGE discharge evenly within the site and without nuisance to the be explained in the Building Fire Safety Regulation 2008.
Adequate site drainage should be installed to ensure that
Visualisations WD.7.03 21.12.2021 C
adjoining properties.
natural runoff is directed away from the proposed
walls and footings. Subsurface drainage must be installed SEWERAGE DRAINAGE
behind retaining walls to prevent development of Sewerage drainage to be in accordance with the local
hydrostatic pressure. authority requirements.
EROSION AND SEDIMENT CONTROL DAMP PROOF COURSE
Provide erosion and sediment control structures to perimeter A damp proof course must be provided in accordance with
of work area and maintain in a functional condition as AS2870.
required by the local authority.
LIGHTING
BUILDING PLATFORM Artificial lighting must be provided in accordance with
Platform immediately surrounding the building is to fall away AS1680.
from from the building at a minimum slope of 1 in 20.
Energy efficient lighting must be 80% min of the total fixed
CUT AND FILL artificial lighting as per QDC.
Cut and fill batters not to exceed a maximum slope of 1 in 1.
WATER SYSTEMS
TERMITE PROTECTION Hot water, warm water and cooling water systems must be
Termite protection to be provided in accordance with AS3660 installed in accordance with AS/NZS3666.1.
with a method to the satisfaction of the Building Certifier.
Solar hot water system, gas hot water system or heat pump
ROOF SHEETING must be supplied in accordance with QDC.
Roof sheeting to be installed in accordance with AS1562.1
and the manufacturers specification for the relevant wind STAIRS AND BALUSTRADES
classification applicable to the site. Stair construction is to comply with NCC part 3.9.1.3 and
3.9.1.4.
STEELWORK
All steelwork fittings and fixtures shall be hot dipped Balustrade positioned min. 865mm above nosing of treads.
galvanised. 1000mm minimum above balcony, landing of the like.
ROOF TRUSSES Opening in balustrades to be constructed so a 125mm
Timber roof trusses to be designed and constructed to the sphere is not permited to pass throught and for a stair the
relevant wind category. space tested is above the nosing.
TIMBER Balustrades to comply with NCC part 3.9.2.2 and 3.9.2.3.
All workmanship and materials shall be in accordance with
AS1684.2 and Engineer's details. SWIMMING POOL
Swimming pool fences to comply with the requirements of
Store timber 150mm minimum clear of ground, evenly the NCC part 3.9.3 (Swimming Pool Access).
supported, well ventilated and protected.
Swimming pool fences must be 1200mm minimun height
Use timbers with durability class and preservative treatment clearance between bottom of fence and finish floor level of
suited to intended application as outlined in AS1684.2. deck must not exceed more than 100mm.
21/12/2021 11:16:20 PM
Swimming pool gates must swing outwards from the pool
area.
For engineering information, Engineer's drawings and information shall take precedence over architectural drawings. 164 Edwards Street, Date: Rev: Issue: Scale: Title: Date:
Client Project
The Building Designer's drawings and recommendations shall take precedence over architectural drawings. The
Amendments
06.08.2021 A Working Drawings 1 : 10 General Notes 21.12.2021
Sunshine Beach
Job Details
author is to be notified immediately, should any errors, discrepancies, or conflict become apparent and prior to
Copyright
05.10.2021 B Outdoor Area Roof & Landscape Plan
proceeding with the works.
Copyright: The design content shown on this drawing remains the property of Garland Design and is provided only 21.12.2021 C Revised Working Drawings in Response to RFI
MCU21/0192 Des: JC Project #: Drawing #: Issue:
for the use described. This drawing may not be copied, altered, have sections omitted, erased or changed in any
way without the prior written approval of Garland Design. Adam Flanagan & Shane Tye Check:JC 21.107 WD.1.02 C