Log in to see the plans as drawn FLOOR AREAS
WD.3.02 UNDERSTOREY PARKING 62m²
1
600 BLOCK PARTY WALL EXTENDS FROM GROUND FLOOR LEVEL
8470
190 8090 190
190 190
190 1900 6000
BLOCK 90 150 PLUMBING DUCT
NOTE
190
190
WD.3.01 2 FALL FALL 2 WD.3.02
6860
6480
7460
7270
8360
STORAGE UNDERSTOREY PARKING
CONCRETE
RL. 33.9 m
PLUMBING DUCT
PLUMBING DUCT
BLOCK 310 BLOCK
190
90
200 490
RL. 33.9 m
1500
90
RL. 33.9 m GRATED VEHICULAR DRAIN RL. 33.9 m
BLOCK RET. WALL
nom. 1200mm HT
3190
REFER GROUND FLOOR PLAN FALL
UNIT 1 PLUNGE POOL FALL BLOCK RET. WALL
UP nom. 1000mm HT
N
REFER GROUND FLOOR PLANS FOR POOL CONC. LANDING RL 35.55 nom.
5900
UP
EXTERNAL CONC. STEPS
7500
max. 950mm HT FROM FGL
190
RL. 34.6 m 300mm WIDE TREADS
190mm RISER MAX.
BLOCK UNDER LANDING
BIN ENCLOSURE
SCREENING
2710
ADDITIONAL CARPARK FALL FALL nom. 1500mm HT
2.4m x 5.4m MIN (SHOWN DASHED)
Garage Plan CONCRETE DRIVEWAY
1 1 : 100
1 FALL
FALL FALL FALL
0 1 2 3 4 5m
1000
WD.3.01GARDEN GARDEN
21/12/2021 11:16:22 PM
LB
For engineering information, Engineer's drawings and information shall take precedence over architectural drawings. 164 Edwards Street, Date: Rev: Issue: Scale: Title: Date:
Client Project
The Building Designer's drawings and recommendations shall take precedence over architectural drawings. The
Amendments
06.08.2021 A Working Drawings 1 : 100 Understorey Park 21.12.2021
Sunshine Beach
Job Details
author is to be notified immediately, should any errors, discrepancies, or conflict become apparent and prior to
Copyright
21.12.2021 C Revised Working Drawings in Response to RFI
proceeding with the works. MCU21/0192
Copyright: The design content shown on this drawing remains the property of Garland Design and is provided only
for the use described. This drawing may not be copied, altered, have sections omitted, erased or changed in any Des: JC Project #: Drawing #: Issue:
way without the prior written approval of Garland Design. Adam Flanagan & Shane Tye Check:JC 21.107 WD.2.02 C